Evaluation of the whole auditory pathway using high-resolution and functional MRI at 7T parallel-transmit.

<h4>Purpose</h4>The aim of the present study is to show a MR procedure for the evaluation of simultaneous left and right auditory functions with functional MRI, and high-resolution acquisition of anatomical auditory pathway using parallel-transmit (pTx) methods at 7T.<h4>Methods<...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Sandra Da Costa, Jérémie Clément, Rolf Gruetter, Özlem Ipek
Formato: article
Lenguaje:EN
Publicado: Public Library of Science (PLoS) 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/d9709f75e9b149158653df129ef598ea
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:d9709f75e9b149158653df129ef598ea
record_format dspace
spelling oai:doaj.org-article:d9709f75e9b149158653df129ef598ea2021-12-02T20:04:42ZEvaluation of the whole auditory pathway using high-resolution and functional MRI at 7T parallel-transmit.1932-620310.1371/journal.pone.0254378https://doaj.org/article/d9709f75e9b149158653df129ef598ea2021-01-01T00:00:00Zhttps://doi.org/10.1371/journal.pone.0254378https://doaj.org/toc/1932-6203<h4>Purpose</h4>The aim of the present study is to show a MR procedure for the evaluation of simultaneous left and right auditory functions with functional MRI, and high-resolution acquisition of anatomical auditory pathway using parallel-transmit (pTx) methods at 7T.<h4>Methods</h4>The time-efficient MR acquisition included two steps: RF weights were optimized for the regions-of-interest and high-resolution MR images of the inner-ear were acquired for the first 30 min (400 μm-iso resolution) followed by functional MRI acquisitions along the whole auditory pathway during the next 20 minutes. Data was processed with a linear cross-correlation analysis to define frequency preferences for each voxel in the auditory relays.<h4>Results</h4>Tonotopic maps revealed ordered bilateral frequency gradients in the auditory relays whereas at the level of the cochlear nuclei and superior olivary complexes the frequency gradients were less evident. A 21% increase in transmit-field efficiency was achieved over the left/right inner-ear regions and thus its main structures were clearly discernible using the pTx methods, compared to a single transmit RF coil.<h4>Conclusion</h4>Using 7T pTx allows a fast (less than 60 min in total) and qualitative evaluation of the simultaneous left and right auditory response along the entire auditory pathway, together with high-resolution anatomical images of the inner-ear. This could be further used for patient examination at 7T.Sandra Da CostaJérémie ClémentRolf GruetterÖzlem IpekPublic Library of Science (PLoS)articleMedicineRScienceQENPLoS ONE, Vol 16, Iss 9, p e0254378 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Sandra Da Costa
Jérémie Clément
Rolf Gruetter
Özlem Ipek
Evaluation of the whole auditory pathway using high-resolution and functional MRI at 7T parallel-transmit.
description <h4>Purpose</h4>The aim of the present study is to show a MR procedure for the evaluation of simultaneous left and right auditory functions with functional MRI, and high-resolution acquisition of anatomical auditory pathway using parallel-transmit (pTx) methods at 7T.<h4>Methods</h4>The time-efficient MR acquisition included two steps: RF weights were optimized for the regions-of-interest and high-resolution MR images of the inner-ear were acquired for the first 30 min (400 μm-iso resolution) followed by functional MRI acquisitions along the whole auditory pathway during the next 20 minutes. Data was processed with a linear cross-correlation analysis to define frequency preferences for each voxel in the auditory relays.<h4>Results</h4>Tonotopic maps revealed ordered bilateral frequency gradients in the auditory relays whereas at the level of the cochlear nuclei and superior olivary complexes the frequency gradients were less evident. A 21% increase in transmit-field efficiency was achieved over the left/right inner-ear regions and thus its main structures were clearly discernible using the pTx methods, compared to a single transmit RF coil.<h4>Conclusion</h4>Using 7T pTx allows a fast (less than 60 min in total) and qualitative evaluation of the simultaneous left and right auditory response along the entire auditory pathway, together with high-resolution anatomical images of the inner-ear. This could be further used for patient examination at 7T.
format article
author Sandra Da Costa
Jérémie Clément
Rolf Gruetter
Özlem Ipek
author_facet Sandra Da Costa
Jérémie Clément
Rolf Gruetter
Özlem Ipek
author_sort Sandra Da Costa
title Evaluation of the whole auditory pathway using high-resolution and functional MRI at 7T parallel-transmit.
title_short Evaluation of the whole auditory pathway using high-resolution and functional MRI at 7T parallel-transmit.
title_full Evaluation of the whole auditory pathway using high-resolution and functional MRI at 7T parallel-transmit.
title_fullStr Evaluation of the whole auditory pathway using high-resolution and functional MRI at 7T parallel-transmit.
title_full_unstemmed Evaluation of the whole auditory pathway using high-resolution and functional MRI at 7T parallel-transmit.
title_sort evaluation of the whole auditory pathway using high-resolution and functional mri at 7t parallel-transmit.
publisher Public Library of Science (PLoS)
publishDate 2021
url https://doaj.org/article/d9709f75e9b149158653df129ef598ea
work_keys_str_mv AT sandradacosta evaluationofthewholeauditorypathwayusinghighresolutionandfunctionalmriat7tparalleltransmit
AT jeremieclement evaluationofthewholeauditorypathwayusinghighresolutionandfunctionalmriat7tparalleltransmit
AT rolfgruetter evaluationofthewholeauditorypathwayusinghighresolutionandfunctionalmriat7tparalleltransmit
AT ozlemipek evaluationofthewholeauditorypathwayusinghighresolutionandfunctionalmriat7tparalleltransmit
_version_ 1718375572803944448