Differential systemic inflammatory responses after TAVI: The role of self versus balloon expandable devices.
<h4>Objective</h4>Transcatheter aortic valve implantation (TAVI) provokes early injury response, represented in part by dynamic changes in the inflammatory markers. The association of self-expanding valves (SEVs) and balloon-expandable valves (BEVs) with the consequent inflammatory respo...
Guardado en:
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Public Library of Science (PLoS)
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/da06e82c7f7c4d4c9ed34347d53049a4 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:da06e82c7f7c4d4c9ed34347d53049a4 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:da06e82c7f7c4d4c9ed34347d53049a42021-12-02T20:13:31ZDifferential systemic inflammatory responses after TAVI: The role of self versus balloon expandable devices.1932-620310.1371/journal.pone.0258963https://doaj.org/article/da06e82c7f7c4d4c9ed34347d53049a42021-01-01T00:00:00Zhttps://doi.org/10.1371/journal.pone.0258963https://doaj.org/toc/1932-6203<h4>Objective</h4>Transcatheter aortic valve implantation (TAVI) provokes early injury response, represented in part by dynamic changes in the inflammatory markers. The association of self-expanding valves (SEVs) and balloon-expandable valves (BEVs) with the consequent inflammatory response remains uncertain.<h4>Materials and methods</h4>Patients with severe symptomatic aortic stenosis who underwent transfemoral TAVI: SEVs or BEVs, from January 2010 to December 2019 were enrolled. Whole white blood cells (WBC) and subpopulation dynamics as well the neutrophil to lymphocyte ratio (NLR) were evaluated.<h4>Results</h4>Three-hundred seventy consecutive patients (mean age 81.75 ± 6.8 years, 199 women's) were enrolled. In the entire population, significant kinetic changes in the WBC response (p <0.0001) between admission and first 24 hours post procedure, with a significant increase in total WBC (7.46 ± 2.26 to 10.08 ± 3.55) and absolute neutrophil count (4.97 ± 2.06 to 8.19 ± 3.43), NL ratio (3.72 ± 2.8 to 9.76 ± 7.29), and a meaningful decrease in absolute lymphocytes count (1.67 ± 1.1 to 1.1 ± 0.76). When compared between the types of valves, SEVs were associated with a more pronounced inflammatory response than BEVs, with total WBC (10.44 ± 3.86 vs. 9.45 ± 3.19) neutrophils (8.56 ± 3.75 vs. 7.55 ± 3.06) with p 0.016 and 0.012 respectively.<h4>Conclusion</h4>This is the first description of a differential inflammatory response between the two leading delivery systems. SEV appears to trigger a more robust inflammatory response as compared to BEV. Clinical studies are warranted to assess the long term effect of our findings.Haitham Abu KhadijaGera GandelmanOmar AyyadMustafa JaberLion PolesMichael JonasOffir PazFiras Abu SbaihGal SellaSara ShimoniJacob GeorgeAlex BlattPublic Library of Science (PLoS)articleMedicineRScienceQENPLoS ONE, Vol 16, Iss 10, p e0258963 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine R Science Q |
spellingShingle |
Medicine R Science Q Haitham Abu Khadija Gera Gandelman Omar Ayyad Mustafa Jaber Lion Poles Michael Jonas Offir Paz Firas Abu Sbaih Gal Sella Sara Shimoni Jacob George Alex Blatt Differential systemic inflammatory responses after TAVI: The role of self versus balloon expandable devices. |
description |
<h4>Objective</h4>Transcatheter aortic valve implantation (TAVI) provokes early injury response, represented in part by dynamic changes in the inflammatory markers. The association of self-expanding valves (SEVs) and balloon-expandable valves (BEVs) with the consequent inflammatory response remains uncertain.<h4>Materials and methods</h4>Patients with severe symptomatic aortic stenosis who underwent transfemoral TAVI: SEVs or BEVs, from January 2010 to December 2019 were enrolled. Whole white blood cells (WBC) and subpopulation dynamics as well the neutrophil to lymphocyte ratio (NLR) were evaluated.<h4>Results</h4>Three-hundred seventy consecutive patients (mean age 81.75 ± 6.8 years, 199 women's) were enrolled. In the entire population, significant kinetic changes in the WBC response (p <0.0001) between admission and first 24 hours post procedure, with a significant increase in total WBC (7.46 ± 2.26 to 10.08 ± 3.55) and absolute neutrophil count (4.97 ± 2.06 to 8.19 ± 3.43), NL ratio (3.72 ± 2.8 to 9.76 ± 7.29), and a meaningful decrease in absolute lymphocytes count (1.67 ± 1.1 to 1.1 ± 0.76). When compared between the types of valves, SEVs were associated with a more pronounced inflammatory response than BEVs, with total WBC (10.44 ± 3.86 vs. 9.45 ± 3.19) neutrophils (8.56 ± 3.75 vs. 7.55 ± 3.06) with p 0.016 and 0.012 respectively.<h4>Conclusion</h4>This is the first description of a differential inflammatory response between the two leading delivery systems. SEV appears to trigger a more robust inflammatory response as compared to BEV. Clinical studies are warranted to assess the long term effect of our findings. |
format |
article |
author |
Haitham Abu Khadija Gera Gandelman Omar Ayyad Mustafa Jaber Lion Poles Michael Jonas Offir Paz Firas Abu Sbaih Gal Sella Sara Shimoni Jacob George Alex Blatt |
author_facet |
Haitham Abu Khadija Gera Gandelman Omar Ayyad Mustafa Jaber Lion Poles Michael Jonas Offir Paz Firas Abu Sbaih Gal Sella Sara Shimoni Jacob George Alex Blatt |
author_sort |
Haitham Abu Khadija |
title |
Differential systemic inflammatory responses after TAVI: The role of self versus balloon expandable devices. |
title_short |
Differential systemic inflammatory responses after TAVI: The role of self versus balloon expandable devices. |
title_full |
Differential systemic inflammatory responses after TAVI: The role of self versus balloon expandable devices. |
title_fullStr |
Differential systemic inflammatory responses after TAVI: The role of self versus balloon expandable devices. |
title_full_unstemmed |
Differential systemic inflammatory responses after TAVI: The role of self versus balloon expandable devices. |
title_sort |
differential systemic inflammatory responses after tavi: the role of self versus balloon expandable devices. |
publisher |
Public Library of Science (PLoS) |
publishDate |
2021 |
url |
https://doaj.org/article/da06e82c7f7c4d4c9ed34347d53049a4 |
work_keys_str_mv |
AT haithamabukhadija differentialsystemicinflammatoryresponsesaftertavitheroleofselfversusballoonexpandabledevices AT geragandelman differentialsystemicinflammatoryresponsesaftertavitheroleofselfversusballoonexpandabledevices AT omarayyad differentialsystemicinflammatoryresponsesaftertavitheroleofselfversusballoonexpandabledevices AT mustafajaber differentialsystemicinflammatoryresponsesaftertavitheroleofselfversusballoonexpandabledevices AT lionpoles differentialsystemicinflammatoryresponsesaftertavitheroleofselfversusballoonexpandabledevices AT michaeljonas differentialsystemicinflammatoryresponsesaftertavitheroleofselfversusballoonexpandabledevices AT offirpaz differentialsystemicinflammatoryresponsesaftertavitheroleofselfversusballoonexpandabledevices AT firasabusbaih differentialsystemicinflammatoryresponsesaftertavitheroleofselfversusballoonexpandabledevices AT galsella differentialsystemicinflammatoryresponsesaftertavitheroleofselfversusballoonexpandabledevices AT sarashimoni differentialsystemicinflammatoryresponsesaftertavitheroleofselfversusballoonexpandabledevices AT jacobgeorge differentialsystemicinflammatoryresponsesaftertavitheroleofselfversusballoonexpandabledevices AT alexblatt differentialsystemicinflammatoryresponsesaftertavitheroleofselfversusballoonexpandabledevices |
_version_ |
1718374795534401536 |