Surgical cup placement affects the heating up of total joint hip replacements
Abstract The long-term success of highly effective total hip arthroplasty (THA) is mainly restricted by aseptic loosening, which is widely associated with friction between the head and cup liner. However, knowledge of the in vivo joint friction and resulting temperature increase is limited. Employin...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Nature Portfolio
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/dade8da9dbba4ec8a395d27a5aec6131 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:dade8da9dbba4ec8a395d27a5aec6131 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:dade8da9dbba4ec8a395d27a5aec61312021-12-02T18:49:29ZSurgical cup placement affects the heating up of total joint hip replacements10.1038/s41598-021-95387-82045-2322https://doaj.org/article/dade8da9dbba4ec8a395d27a5aec61312021-08-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-95387-8https://doaj.org/toc/2045-2322Abstract The long-term success of highly effective total hip arthroplasty (THA) is mainly restricted by aseptic loosening, which is widely associated with friction between the head and cup liner. However, knowledge of the in vivo joint friction and resulting temperature increase is limited. Employing a novel combination of in vivo and in silico technologies, we analyzed the hypothesis that the intraoperatively defined implant orientation defines the individual joint roofing, friction and its associated temperature increase. A total of 38,000 in vivo activity trials from a special group of 10 subjects with instrumented THA implants with an identical material combination were analyzed and showed a significant link between implant orientation, joint kinematics, joint roofing and friction-induced temperature increase but surprisingly not with acting joint contact force magnitude. This combined in vivo and in silico analysis revealed that cup placement in relation to the stem is key to the in vivo joint friction and heating-up of THA. Thus, intraoperative placement, and not only articulating materials, should be the focus of further improvements, especially for young and more active patients.Philipp DammAlwina BenderVivian WaldheimTobias WinklerGeorg N. DudaNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-11 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine R Science Q |
spellingShingle |
Medicine R Science Q Philipp Damm Alwina Bender Vivian Waldheim Tobias Winkler Georg N. Duda Surgical cup placement affects the heating up of total joint hip replacements |
description |
Abstract The long-term success of highly effective total hip arthroplasty (THA) is mainly restricted by aseptic loosening, which is widely associated with friction between the head and cup liner. However, knowledge of the in vivo joint friction and resulting temperature increase is limited. Employing a novel combination of in vivo and in silico technologies, we analyzed the hypothesis that the intraoperatively defined implant orientation defines the individual joint roofing, friction and its associated temperature increase. A total of 38,000 in vivo activity trials from a special group of 10 subjects with instrumented THA implants with an identical material combination were analyzed and showed a significant link between implant orientation, joint kinematics, joint roofing and friction-induced temperature increase but surprisingly not with acting joint contact force magnitude. This combined in vivo and in silico analysis revealed that cup placement in relation to the stem is key to the in vivo joint friction and heating-up of THA. Thus, intraoperative placement, and not only articulating materials, should be the focus of further improvements, especially for young and more active patients. |
format |
article |
author |
Philipp Damm Alwina Bender Vivian Waldheim Tobias Winkler Georg N. Duda |
author_facet |
Philipp Damm Alwina Bender Vivian Waldheim Tobias Winkler Georg N. Duda |
author_sort |
Philipp Damm |
title |
Surgical cup placement affects the heating up of total joint hip replacements |
title_short |
Surgical cup placement affects the heating up of total joint hip replacements |
title_full |
Surgical cup placement affects the heating up of total joint hip replacements |
title_fullStr |
Surgical cup placement affects the heating up of total joint hip replacements |
title_full_unstemmed |
Surgical cup placement affects the heating up of total joint hip replacements |
title_sort |
surgical cup placement affects the heating up of total joint hip replacements |
publisher |
Nature Portfolio |
publishDate |
2021 |
url |
https://doaj.org/article/dade8da9dbba4ec8a395d27a5aec6131 |
work_keys_str_mv |
AT philippdamm surgicalcupplacementaffectstheheatingupoftotaljointhipreplacements AT alwinabender surgicalcupplacementaffectstheheatingupoftotaljointhipreplacements AT vivianwaldheim surgicalcupplacementaffectstheheatingupoftotaljointhipreplacements AT tobiaswinkler surgicalcupplacementaffectstheheatingupoftotaljointhipreplacements AT georgnduda surgicalcupplacementaffectstheheatingupoftotaljointhipreplacements |
_version_ |
1718377594831765504 |