A new device used in the restoration of kinematics after total facet arthroplasty

D Vermesan,1 R Prejbeanu,1 C Vlad Daliborca,1 H Haragus,1 M Magureanu,2 M Marrelli,3–5 L Promenzio,4 M Caprio,6 R Cagiano,6,* M Tatullo3,5,* 1Victor Babes University of Medicine and Pharmacy, Timisoara, 2Carol Davila University of Medicine and Pharmacy, Bucharest, Romania; 3Maxillofacia...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Vermesan D, Prejbeanu R, Daliborca CV, Haragus H, Magureanu M, Marrelli M, Promenzio L, Caprio M, Cagiano R, Tatullo M
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2014
Materias:
Acceso en línea:https://doaj.org/article/dcd99f9ff50e48478adba44aea656a3d
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:dcd99f9ff50e48478adba44aea656a3d
record_format dspace
spelling oai:doaj.org-article:dcd99f9ff50e48478adba44aea656a3d2021-12-02T02:41:07ZA new device used in the restoration of kinematics after total facet arthroplasty1179-1470https://doaj.org/article/dcd99f9ff50e48478adba44aea656a3d2014-05-01T00:00:00Zhttp://www.dovepress.com/a-new-device-used-in-the-restoration-of-kinematics-after-total-facet-a-a17068https://doaj.org/toc/1179-1470 D Vermesan,1 R Prejbeanu,1 C Vlad Daliborca,1 H Haragus,1 M Magureanu,2 M Marrelli,3–5 L Promenzio,4 M Caprio,6 R Cagiano,6,* M Tatullo3,5,* 1Victor Babes University of Medicine and Pharmacy, Timisoara, 2Carol Davila University of Medicine and Pharmacy, Bucharest, Romania; 3Maxillofacial Unit, Dental Center Calabrodental, 4Orthopedics and Traumatology Unit, Marrelli Hospital, 5Biomedical Section, Tecnologica Research Institute, Crotone, 6Department of Biomedical Sciences and Human Oncology, Medical Faculty, Aldo Moro University of Bari, Bari, Italy *These authors contributed equally to this work Abstract: Facet degeneration can lead to spinal stenosis and instability, and often requires stabilization. Interbody fusion is commonly performed, but it can lead to adjacent-segment disease. Dynamic posterior stabilization was performed using a total facet arthroplasty system. The total facet arthroplasty system was originally intended to restore the natural motion of the posterior stabilizers, but follow-up studies are lacking due to limited clinical use. We studied the first 14 cases (long-term follow-up) treated with this new device in our clinic. All patients were diagnosed with lumbar stenosis due to hypertrophy of the articular facets on one to three levels (maximum). Disk space was of normal height. The design of this implant allows its use only at levels L3–L4 and L4–L5. We implanted nine patients at the L4–L5 level and four patients at level L3–L4. Postoperative follow-up of the patients was obtained for an average of 3.7 years. All patients reported persistent improvement of symptoms, visual analog scale score, and Oswestry Disability Index score. Functional scores and dynamic radiographic imaging demonstrated the functional efficacy of this new implant, which represents an alternative technique and a new approach to dynamic stabilization of the vertebral column after interventions for spine decompression. The total facet arthroplasty system represents a viable option for dynamic posterior stabilization after spinal decompression. For the observed follow-up, it preserved motion without significant complications or apparent intradisk or adjacent-disk degeneration. Keywords: lumbar stenosis, dynamic facet arthroplasty, dynamic stabilization, vertebral fusionVermesan DPrejbeanu RDaliborca CVHaragus HMagureanu MMarrelli MPromenzio LCaprio MCagiano RTatullo MDove Medical PressarticleMedical technologyR855-855.5ENMedical Devices: Evidence and Research, Vol 2014, Iss default, Pp 157-163 (2014)
institution DOAJ
collection DOAJ
language EN
topic Medical technology
R855-855.5
spellingShingle Medical technology
R855-855.5
Vermesan D
Prejbeanu R
Daliborca CV
Haragus H
Magureanu M
Marrelli M
Promenzio L
Caprio M
Cagiano R
Tatullo M
A new device used in the restoration of kinematics after total facet arthroplasty
description D Vermesan,1 R Prejbeanu,1 C Vlad Daliborca,1 H Haragus,1 M Magureanu,2 M Marrelli,3–5 L Promenzio,4 M Caprio,6 R Cagiano,6,* M Tatullo3,5,* 1Victor Babes University of Medicine and Pharmacy, Timisoara, 2Carol Davila University of Medicine and Pharmacy, Bucharest, Romania; 3Maxillofacial Unit, Dental Center Calabrodental, 4Orthopedics and Traumatology Unit, Marrelli Hospital, 5Biomedical Section, Tecnologica Research Institute, Crotone, 6Department of Biomedical Sciences and Human Oncology, Medical Faculty, Aldo Moro University of Bari, Bari, Italy *These authors contributed equally to this work Abstract: Facet degeneration can lead to spinal stenosis and instability, and often requires stabilization. Interbody fusion is commonly performed, but it can lead to adjacent-segment disease. Dynamic posterior stabilization was performed using a total facet arthroplasty system. The total facet arthroplasty system was originally intended to restore the natural motion of the posterior stabilizers, but follow-up studies are lacking due to limited clinical use. We studied the first 14 cases (long-term follow-up) treated with this new device in our clinic. All patients were diagnosed with lumbar stenosis due to hypertrophy of the articular facets on one to three levels (maximum). Disk space was of normal height. The design of this implant allows its use only at levels L3–L4 and L4–L5. We implanted nine patients at the L4–L5 level and four patients at level L3–L4. Postoperative follow-up of the patients was obtained for an average of 3.7 years. All patients reported persistent improvement of symptoms, visual analog scale score, and Oswestry Disability Index score. Functional scores and dynamic radiographic imaging demonstrated the functional efficacy of this new implant, which represents an alternative technique and a new approach to dynamic stabilization of the vertebral column after interventions for spine decompression. The total facet arthroplasty system represents a viable option for dynamic posterior stabilization after spinal decompression. For the observed follow-up, it preserved motion without significant complications or apparent intradisk or adjacent-disk degeneration. Keywords: lumbar stenosis, dynamic facet arthroplasty, dynamic stabilization, vertebral fusion
format article
author Vermesan D
Prejbeanu R
Daliborca CV
Haragus H
Magureanu M
Marrelli M
Promenzio L
Caprio M
Cagiano R
Tatullo M
author_facet Vermesan D
Prejbeanu R
Daliborca CV
Haragus H
Magureanu M
Marrelli M
Promenzio L
Caprio M
Cagiano R
Tatullo M
author_sort Vermesan D
title A new device used in the restoration of kinematics after total facet arthroplasty
title_short A new device used in the restoration of kinematics after total facet arthroplasty
title_full A new device used in the restoration of kinematics after total facet arthroplasty
title_fullStr A new device used in the restoration of kinematics after total facet arthroplasty
title_full_unstemmed A new device used in the restoration of kinematics after total facet arthroplasty
title_sort new device used in the restoration of kinematics after total facet arthroplasty
publisher Dove Medical Press
publishDate 2014
url https://doaj.org/article/dcd99f9ff50e48478adba44aea656a3d
work_keys_str_mv AT vermesand anewdeviceusedintherestorationofkinematicsaftertotalfacetarthroplasty
AT prejbeanur anewdeviceusedintherestorationofkinematicsaftertotalfacetarthroplasty
AT daliborcacv anewdeviceusedintherestorationofkinematicsaftertotalfacetarthroplasty
AT haragush anewdeviceusedintherestorationofkinematicsaftertotalfacetarthroplasty
AT magureanum anewdeviceusedintherestorationofkinematicsaftertotalfacetarthroplasty
AT marrellim anewdeviceusedintherestorationofkinematicsaftertotalfacetarthroplasty
AT promenziol anewdeviceusedintherestorationofkinematicsaftertotalfacetarthroplasty
AT capriom anewdeviceusedintherestorationofkinematicsaftertotalfacetarthroplasty
AT cagianor anewdeviceusedintherestorationofkinematicsaftertotalfacetarthroplasty
AT tatullom anewdeviceusedintherestorationofkinematicsaftertotalfacetarthroplasty
AT vermesand newdeviceusedintherestorationofkinematicsaftertotalfacetarthroplasty
AT prejbeanur newdeviceusedintherestorationofkinematicsaftertotalfacetarthroplasty
AT daliborcacv newdeviceusedintherestorationofkinematicsaftertotalfacetarthroplasty
AT haragush newdeviceusedintherestorationofkinematicsaftertotalfacetarthroplasty
AT magureanum newdeviceusedintherestorationofkinematicsaftertotalfacetarthroplasty
AT marrellim newdeviceusedintherestorationofkinematicsaftertotalfacetarthroplasty
AT promenziol newdeviceusedintherestorationofkinematicsaftertotalfacetarthroplasty
AT capriom newdeviceusedintherestorationofkinematicsaftertotalfacetarthroplasty
AT cagianor newdeviceusedintherestorationofkinematicsaftertotalfacetarthroplasty
AT tatullom newdeviceusedintherestorationofkinematicsaftertotalfacetarthroplasty
_version_ 1718402319646720000