A Refined Load Distribution Method for Large Hydropower Stations With Multiple Units Considering Constraints of Substations
Large hydropower stations often undertake peak regulation tasks during the non-abandoning water season. This requires a reasonable arrangement of unit commitment and load distribution (UCLD). In this study, a load distribution model considering constraints of substations was established, and a novel...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
IEEE
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/dd3a899b049d4fde9f3fb53209e4d2b2 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:dd3a899b049d4fde9f3fb53209e4d2b2 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:dd3a899b049d4fde9f3fb53209e4d2b22021-11-25T00:00:18ZA Refined Load Distribution Method for Large Hydropower Stations With Multiple Units Considering Constraints of Substations2169-353610.1109/ACCESS.2021.3126764https://doaj.org/article/dd3a899b049d4fde9f3fb53209e4d2b22021-01-01T00:00:00Zhttps://ieeexplore.ieee.org/document/9606912/https://doaj.org/toc/2169-3536Large hydropower stations often undertake peak regulation tasks during the non-abandoning water season. This requires a reasonable arrangement of unit commitment and load distribution (UCLD). In this study, a load distribution model considering constraints of substations was established, and a novel refined and practical method (RPM) was proposed by considering a whole plant-substation module, substation-unit module, and adjustment module along with practical strategies. The Three Gorges hydropower station in China was selected to demonstrate the effects of the RPM. The results showed that the RPM with high calculation timeliness can obtain UCLD schemes with high rationality and practicability under the constraints of the whole plant, substations, and units. The relative mean absolute error of the simulation outflow could be controlled within 1%, thereby providing a valuable reference for forecasting the outflow process which involving the unit level.Xiao ChenJianzhong ZhouBenjun JiaIEEEarticleLarge hydropower stationsload distributionsubstation constraintsoutput adjustment strategiesbus connection switching statusElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENIEEE Access, Vol 9, Pp 154524-154539 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Large hydropower stations load distribution substation constraints output adjustment strategies bus connection switching status Electrical engineering. Electronics. Nuclear engineering TK1-9971 |
spellingShingle |
Large hydropower stations load distribution substation constraints output adjustment strategies bus connection switching status Electrical engineering. Electronics. Nuclear engineering TK1-9971 Xiao Chen Jianzhong Zhou Benjun Jia A Refined Load Distribution Method for Large Hydropower Stations With Multiple Units Considering Constraints of Substations |
description |
Large hydropower stations often undertake peak regulation tasks during the non-abandoning water season. This requires a reasonable arrangement of unit commitment and load distribution (UCLD). In this study, a load distribution model considering constraints of substations was established, and a novel refined and practical method (RPM) was proposed by considering a whole plant-substation module, substation-unit module, and adjustment module along with practical strategies. The Three Gorges hydropower station in China was selected to demonstrate the effects of the RPM. The results showed that the RPM with high calculation timeliness can obtain UCLD schemes with high rationality and practicability under the constraints of the whole plant, substations, and units. The relative mean absolute error of the simulation outflow could be controlled within 1%, thereby providing a valuable reference for forecasting the outflow process which involving the unit level. |
format |
article |
author |
Xiao Chen Jianzhong Zhou Benjun Jia |
author_facet |
Xiao Chen Jianzhong Zhou Benjun Jia |
author_sort |
Xiao Chen |
title |
A Refined Load Distribution Method for Large Hydropower Stations With Multiple Units Considering Constraints of Substations |
title_short |
A Refined Load Distribution Method for Large Hydropower Stations With Multiple Units Considering Constraints of Substations |
title_full |
A Refined Load Distribution Method for Large Hydropower Stations With Multiple Units Considering Constraints of Substations |
title_fullStr |
A Refined Load Distribution Method for Large Hydropower Stations With Multiple Units Considering Constraints of Substations |
title_full_unstemmed |
A Refined Load Distribution Method for Large Hydropower Stations With Multiple Units Considering Constraints of Substations |
title_sort |
refined load distribution method for large hydropower stations with multiple units considering constraints of substations |
publisher |
IEEE |
publishDate |
2021 |
url |
https://doaj.org/article/dd3a899b049d4fde9f3fb53209e4d2b2 |
work_keys_str_mv |
AT xiaochen arefinedloaddistributionmethodforlargehydropowerstationswithmultipleunitsconsideringconstraintsofsubstations AT jianzhongzhou arefinedloaddistributionmethodforlargehydropowerstationswithmultipleunitsconsideringconstraintsofsubstations AT benjunjia arefinedloaddistributionmethodforlargehydropowerstationswithmultipleunitsconsideringconstraintsofsubstations AT xiaochen refinedloaddistributionmethodforlargehydropowerstationswithmultipleunitsconsideringconstraintsofsubstations AT jianzhongzhou refinedloaddistributionmethodforlargehydropowerstationswithmultipleunitsconsideringconstraintsofsubstations AT benjunjia refinedloaddistributionmethodforlargehydropowerstationswithmultipleunitsconsideringconstraintsofsubstations |
_version_ |
1718414726314065920 |