A Refined Load Distribution Method for Large Hydropower Stations With Multiple Units Considering Constraints of Substations

Large hydropower stations often undertake peak regulation tasks during the non-abandoning water season. This requires a reasonable arrangement of unit commitment and load distribution (UCLD). In this study, a load distribution model considering constraints of substations was established, and a novel...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Xiao Chen, Jianzhong Zhou, Benjun Jia
Formato: article
Lenguaje:EN
Publicado: IEEE 2021
Materias:
Acceso en línea:https://doaj.org/article/dd3a899b049d4fde9f3fb53209e4d2b2
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:dd3a899b049d4fde9f3fb53209e4d2b2
record_format dspace
spelling oai:doaj.org-article:dd3a899b049d4fde9f3fb53209e4d2b22021-11-25T00:00:18ZA Refined Load Distribution Method for Large Hydropower Stations With Multiple Units Considering Constraints of Substations2169-353610.1109/ACCESS.2021.3126764https://doaj.org/article/dd3a899b049d4fde9f3fb53209e4d2b22021-01-01T00:00:00Zhttps://ieeexplore.ieee.org/document/9606912/https://doaj.org/toc/2169-3536Large hydropower stations often undertake peak regulation tasks during the non-abandoning water season. This requires a reasonable arrangement of unit commitment and load distribution (UCLD). In this study, a load distribution model considering constraints of substations was established, and a novel refined and practical method (RPM) was proposed by considering a whole plant-substation module, substation-unit module, and adjustment module along with practical strategies. The Three Gorges hydropower station in China was selected to demonstrate the effects of the RPM. The results showed that the RPM with high calculation timeliness can obtain UCLD schemes with high rationality and practicability under the constraints of the whole plant, substations, and units. The relative mean absolute error of the simulation outflow could be controlled within 1%, thereby providing a valuable reference for forecasting the outflow process which involving the unit level.Xiao ChenJianzhong ZhouBenjun JiaIEEEarticleLarge hydropower stationsload distributionsubstation constraintsoutput adjustment strategiesbus connection switching statusElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENIEEE Access, Vol 9, Pp 154524-154539 (2021)
institution DOAJ
collection DOAJ
language EN
topic Large hydropower stations
load distribution
substation constraints
output adjustment strategies
bus connection switching status
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
spellingShingle Large hydropower stations
load distribution
substation constraints
output adjustment strategies
bus connection switching status
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
Xiao Chen
Jianzhong Zhou
Benjun Jia
A Refined Load Distribution Method for Large Hydropower Stations With Multiple Units Considering Constraints of Substations
description Large hydropower stations often undertake peak regulation tasks during the non-abandoning water season. This requires a reasonable arrangement of unit commitment and load distribution (UCLD). In this study, a load distribution model considering constraints of substations was established, and a novel refined and practical method (RPM) was proposed by considering a whole plant-substation module, substation-unit module, and adjustment module along with practical strategies. The Three Gorges hydropower station in China was selected to demonstrate the effects of the RPM. The results showed that the RPM with high calculation timeliness can obtain UCLD schemes with high rationality and practicability under the constraints of the whole plant, substations, and units. The relative mean absolute error of the simulation outflow could be controlled within 1%, thereby providing a valuable reference for forecasting the outflow process which involving the unit level.
format article
author Xiao Chen
Jianzhong Zhou
Benjun Jia
author_facet Xiao Chen
Jianzhong Zhou
Benjun Jia
author_sort Xiao Chen
title A Refined Load Distribution Method for Large Hydropower Stations With Multiple Units Considering Constraints of Substations
title_short A Refined Load Distribution Method for Large Hydropower Stations With Multiple Units Considering Constraints of Substations
title_full A Refined Load Distribution Method for Large Hydropower Stations With Multiple Units Considering Constraints of Substations
title_fullStr A Refined Load Distribution Method for Large Hydropower Stations With Multiple Units Considering Constraints of Substations
title_full_unstemmed A Refined Load Distribution Method for Large Hydropower Stations With Multiple Units Considering Constraints of Substations
title_sort refined load distribution method for large hydropower stations with multiple units considering constraints of substations
publisher IEEE
publishDate 2021
url https://doaj.org/article/dd3a899b049d4fde9f3fb53209e4d2b2
work_keys_str_mv AT xiaochen arefinedloaddistributionmethodforlargehydropowerstationswithmultipleunitsconsideringconstraintsofsubstations
AT jianzhongzhou arefinedloaddistributionmethodforlargehydropowerstationswithmultipleunitsconsideringconstraintsofsubstations
AT benjunjia arefinedloaddistributionmethodforlargehydropowerstationswithmultipleunitsconsideringconstraintsofsubstations
AT xiaochen refinedloaddistributionmethodforlargehydropowerstationswithmultipleunitsconsideringconstraintsofsubstations
AT jianzhongzhou refinedloaddistributionmethodforlargehydropowerstationswithmultipleunitsconsideringconstraintsofsubstations
AT benjunjia refinedloaddistributionmethodforlargehydropowerstationswithmultipleunitsconsideringconstraintsofsubstations
_version_ 1718414726314065920