Quantitative measurement of heat transfer fluctuation in a pipe flow around an orifice plate using high-speed infrared thermography

The aim of the present study is to demonstrate the quantitative measurement of the spatio-temporal fluctuation of the heat transfer in a water pipe flow around an orifice plate. In the present study, a technique using high-speed infrared thermography was used to measure the heat transfer. The measur...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Naoki SHIIBARA, Hajime NAKAMURA, Shunsuke YAMADA
Formato: article
Lenguaje:EN
Publicado: The Japan Society of Mechanical Engineers 2015
Materias:
Acceso en línea:https://doaj.org/article/dd434942596c4c58a37f0f286a79c64f
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:dd434942596c4c58a37f0f286a79c64f
record_format dspace
spelling oai:doaj.org-article:dd434942596c4c58a37f0f286a79c64f2021-11-26T06:32:14ZQuantitative measurement of heat transfer fluctuation in a pipe flow around an orifice plate using high-speed infrared thermography2187-974510.1299/mej.15-00312https://doaj.org/article/dd434942596c4c58a37f0f286a79c64f2015-12-01T00:00:00Zhttps://www.jstage.jst.go.jp/article/mej/2/6/2_15-00312/_pdf/-char/enhttps://doaj.org/toc/2187-9745The aim of the present study is to demonstrate the quantitative measurement of the spatio-temporal fluctuation of the heat transfer in a water pipe flow around an orifice plate. In the present study, a technique using high-speed infrared thermography was used to measure the heat transfer. The measurement was first performed for a fully developed pipe flow without installing an orifice plate in order to verify the validity of the measurement technique. The spatio-temporal distribution of the heat transfer coefficient was evaluated based on the temperature fluctuation of a heated thin-foil measured using high-speed infrared thermography, and the results indicated that quantitative measurement was possible not only for time-averaged values, but also for fluctuating values. The technique was then used to measure the heat transfer to the flow around an orifice plate (the bore ratio was approximately 0.5). As a result, it was revealed that the heat transfer downstream of the orifice fluctuated violently, and the instantaneous structure of the heat transfer was remarkably finer than the streaky structure for the fully developed pipe flow. The time-averaged value of the heat transfer had a maximum at approximately two diameters downstream of the orifice, where the rms value of the fluctuation and its characteristic frequency also became much higher than those for the fully developed pipe flow.Naoki SHIIBARAHajime NAKAMURAShunsuke YAMADAThe Japan Society of Mechanical Engineersarticleturbulent flowunsteady flowpipe flowforced convectionheat transferseparationreattachmentspatio-temporal measurementinfrared thermographyMechanical engineering and machineryTJ1-1570ENMechanical Engineering Journal, Vol 2, Iss 6, Pp 15-00312-15-00312 (2015)
institution DOAJ
collection DOAJ
language EN
topic turbulent flow
unsteady flow
pipe flow
forced convection
heat transfer
separation
reattachment
spatio-temporal measurement
infrared thermography
Mechanical engineering and machinery
TJ1-1570
spellingShingle turbulent flow
unsteady flow
pipe flow
forced convection
heat transfer
separation
reattachment
spatio-temporal measurement
infrared thermography
Mechanical engineering and machinery
TJ1-1570
Naoki SHIIBARA
Hajime NAKAMURA
Shunsuke YAMADA
Quantitative measurement of heat transfer fluctuation in a pipe flow around an orifice plate using high-speed infrared thermography
description The aim of the present study is to demonstrate the quantitative measurement of the spatio-temporal fluctuation of the heat transfer in a water pipe flow around an orifice plate. In the present study, a technique using high-speed infrared thermography was used to measure the heat transfer. The measurement was first performed for a fully developed pipe flow without installing an orifice plate in order to verify the validity of the measurement technique. The spatio-temporal distribution of the heat transfer coefficient was evaluated based on the temperature fluctuation of a heated thin-foil measured using high-speed infrared thermography, and the results indicated that quantitative measurement was possible not only for time-averaged values, but also for fluctuating values. The technique was then used to measure the heat transfer to the flow around an orifice plate (the bore ratio was approximately 0.5). As a result, it was revealed that the heat transfer downstream of the orifice fluctuated violently, and the instantaneous structure of the heat transfer was remarkably finer than the streaky structure for the fully developed pipe flow. The time-averaged value of the heat transfer had a maximum at approximately two diameters downstream of the orifice, where the rms value of the fluctuation and its characteristic frequency also became much higher than those for the fully developed pipe flow.
format article
author Naoki SHIIBARA
Hajime NAKAMURA
Shunsuke YAMADA
author_facet Naoki SHIIBARA
Hajime NAKAMURA
Shunsuke YAMADA
author_sort Naoki SHIIBARA
title Quantitative measurement of heat transfer fluctuation in a pipe flow around an orifice plate using high-speed infrared thermography
title_short Quantitative measurement of heat transfer fluctuation in a pipe flow around an orifice plate using high-speed infrared thermography
title_full Quantitative measurement of heat transfer fluctuation in a pipe flow around an orifice plate using high-speed infrared thermography
title_fullStr Quantitative measurement of heat transfer fluctuation in a pipe flow around an orifice plate using high-speed infrared thermography
title_full_unstemmed Quantitative measurement of heat transfer fluctuation in a pipe flow around an orifice plate using high-speed infrared thermography
title_sort quantitative measurement of heat transfer fluctuation in a pipe flow around an orifice plate using high-speed infrared thermography
publisher The Japan Society of Mechanical Engineers
publishDate 2015
url https://doaj.org/article/dd434942596c4c58a37f0f286a79c64f
work_keys_str_mv AT naokishiibara quantitativemeasurementofheattransferfluctuationinapipeflowaroundanorificeplateusinghighspeedinfraredthermography
AT hajimenakamura quantitativemeasurementofheattransferfluctuationinapipeflowaroundanorificeplateusinghighspeedinfraredthermography
AT shunsukeyamada quantitativemeasurementofheattransferfluctuationinapipeflowaroundanorificeplateusinghighspeedinfraredthermography
_version_ 1718409812683784192