Numerical comparison between conventional and interdigitated flow fields in Proton Exchange Membrane Fuel Cells (PEMFCs)

The recent trend towards the decarbonization of the energy system has renewed the scientific community's interest in fuel cells. These devices have the potential to eliminate, or greatly reduce, the production of greenhouse gases. Polymeric Electrolyte Membrane Fuel Cells (PEMFC) are among the...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Corda Giuseppe, d’Adamo Alessandro, Riccardi Matteo
Formato: article
Lenguaje:EN
FR
Publicado: EDP Sciences 2021
Materias:
Acceso en línea:https://doaj.org/article/dd4b68f1a0f7419ca3656d4f069ed1d4
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:dd4b68f1a0f7419ca3656d4f069ed1d4
record_format dspace
spelling oai:doaj.org-article:dd4b68f1a0f7419ca3656d4f069ed1d42021-11-08T15:18:51ZNumerical comparison between conventional and interdigitated flow fields in Proton Exchange Membrane Fuel Cells (PEMFCs)2267-124210.1051/e3sconf/202131207016https://doaj.org/article/dd4b68f1a0f7419ca3656d4f069ed1d42021-01-01T00:00:00Zhttps://www.e3s-conferences.org/articles/e3sconf/pdf/2021/88/e3sconf_ati2021_07016.pdfhttps://doaj.org/toc/2267-1242The recent trend towards the decarbonization of the energy system has renewed the scientific community's interest in fuel cells. These devices have the potential to eliminate, or greatly reduce, the production of greenhouse gases. Polymeric Electrolyte Membrane Fuel Cells (PEMFC) are among the most promising technologies in this regard, being suited for various applications in stationary power plants, vehicles, and portable power devices. The critical issues in PEMFC are the limitation of oxygen transport through the air cathode and water management at high current density operation, which could be largely limited by modifying the design of the reactant supplier channels. In this paper, a three-dimensional CFD approach is used to compare straight and interdigitated flow fields, focusing on the increased current density and improved water management in the diffusion and catalyst layers for the interdigitated design. The simulation results show that the fluid is forced to flow through the porous layers, promoting a convection-type transport, leading to better water removal from the porous layers as well as to increased transport rates of reactants/products to/from the catalyst layers. This leads to reduced concentration overpotentials, and it shows the potential of simulation-driven design for high energy density PEMFC systems.Corda Giusepped’Adamo AlessandroRiccardi MatteoEDP SciencesarticleEnvironmental sciencesGE1-350ENFRE3S Web of Conferences, Vol 312, p 07016 (2021)
institution DOAJ
collection DOAJ
language EN
FR
topic Environmental sciences
GE1-350
spellingShingle Environmental sciences
GE1-350
Corda Giuseppe
d’Adamo Alessandro
Riccardi Matteo
Numerical comparison between conventional and interdigitated flow fields in Proton Exchange Membrane Fuel Cells (PEMFCs)
description The recent trend towards the decarbonization of the energy system has renewed the scientific community's interest in fuel cells. These devices have the potential to eliminate, or greatly reduce, the production of greenhouse gases. Polymeric Electrolyte Membrane Fuel Cells (PEMFC) are among the most promising technologies in this regard, being suited for various applications in stationary power plants, vehicles, and portable power devices. The critical issues in PEMFC are the limitation of oxygen transport through the air cathode and water management at high current density operation, which could be largely limited by modifying the design of the reactant supplier channels. In this paper, a three-dimensional CFD approach is used to compare straight and interdigitated flow fields, focusing on the increased current density and improved water management in the diffusion and catalyst layers for the interdigitated design. The simulation results show that the fluid is forced to flow through the porous layers, promoting a convection-type transport, leading to better water removal from the porous layers as well as to increased transport rates of reactants/products to/from the catalyst layers. This leads to reduced concentration overpotentials, and it shows the potential of simulation-driven design for high energy density PEMFC systems.
format article
author Corda Giuseppe
d’Adamo Alessandro
Riccardi Matteo
author_facet Corda Giuseppe
d’Adamo Alessandro
Riccardi Matteo
author_sort Corda Giuseppe
title Numerical comparison between conventional and interdigitated flow fields in Proton Exchange Membrane Fuel Cells (PEMFCs)
title_short Numerical comparison between conventional and interdigitated flow fields in Proton Exchange Membrane Fuel Cells (PEMFCs)
title_full Numerical comparison between conventional and interdigitated flow fields in Proton Exchange Membrane Fuel Cells (PEMFCs)
title_fullStr Numerical comparison between conventional and interdigitated flow fields in Proton Exchange Membrane Fuel Cells (PEMFCs)
title_full_unstemmed Numerical comparison between conventional and interdigitated flow fields in Proton Exchange Membrane Fuel Cells (PEMFCs)
title_sort numerical comparison between conventional and interdigitated flow fields in proton exchange membrane fuel cells (pemfcs)
publisher EDP Sciences
publishDate 2021
url https://doaj.org/article/dd4b68f1a0f7419ca3656d4f069ed1d4
work_keys_str_mv AT cordagiuseppe numericalcomparisonbetweenconventionalandinterdigitatedflowfieldsinprotonexchangemembranefuelcellspemfcs
AT dadamoalessandro numericalcomparisonbetweenconventionalandinterdigitatedflowfieldsinprotonexchangemembranefuelcellspemfcs
AT riccardimatteo numericalcomparisonbetweenconventionalandinterdigitatedflowfieldsinprotonexchangemembranefuelcellspemfcs
_version_ 1718441997679722496