Value of prominent flow voids without cord edema in the detection of spinal arteriovenous fistulae.

<h4>Purpose</h4>To determine the prevalence of spinal dural arteriovenous fistulae (SDAVF) in patients presenting with prominent vascular flow voids on imaging without other imaging findings suggestive of SDAVF.<h4>Methods</h4>We retrospectively identified patients from Janua...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Lea M Alhilali, Arich R Reynolds, Saeed Fakhran
Formato: article
Lenguaje:EN
Publicado: Public Library of Science (PLoS) 2014
Materias:
R
Q
Acceso en línea:https://doaj.org/article/de05eee0cbb643da8c6aec0c005f4a45
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:de05eee0cbb643da8c6aec0c005f4a45
record_format dspace
spelling oai:doaj.org-article:de05eee0cbb643da8c6aec0c005f4a452021-11-18T08:16:46ZValue of prominent flow voids without cord edema in the detection of spinal arteriovenous fistulae.1932-620310.1371/journal.pone.0099004https://doaj.org/article/de05eee0cbb643da8c6aec0c005f4a452014-01-01T00:00:00Zhttps://www.ncbi.nlm.nih.gov/pmc/articles/pmid/24905497/?tool=EBIhttps://doaj.org/toc/1932-6203<h4>Purpose</h4>To determine the prevalence of spinal dural arteriovenous fistulae (SDAVF) in patients presenting with prominent vascular flow voids on imaging without other imaging findings suggestive of SDAVF.<h4>Methods</h4>We retrospectively identified patients from January 1, 2005 to March 1, 2012 who underwent spinal angiography for suspected SDAVF with prominent vascular flow voids on prior imaging. We excluded patients with other major spinal pathology or other imaging findings of SDAVF including cord hyperintensity, enhancement, or expansion. We calculated the proportion of patients with positive findings for SDAVF on angiography and evaluated the prevalence of SDAVF for this finding alone and in correlation with clinical findings.<h4>Results</h4>18 patients underwent spinal angiography for prominent flow voids on imaging without other spinal pathology or imaging findings of SDAVF. Three had a SDAVF detected on angiography. The prevalence of SDAVF in this population was low, only 17% (95% CI 6-39%). All of the patients with positive angiography findings had myelopathy, increasing the prevalence to 100% if the additional clinical finding of myelopathy was present.<h4>Conclusions</h4>Prominent flow voids without other imaging findings suggestive of SDAVF is poorly predictive of the presence of a SDAVF, unless myelopathy is present clinically.Lea M AlhilaliArich R ReynoldsSaeed FakhranPublic Library of Science (PLoS)articleMedicineRScienceQENPLoS ONE, Vol 9, Iss 6, p e99004 (2014)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Lea M Alhilali
Arich R Reynolds
Saeed Fakhran
Value of prominent flow voids without cord edema in the detection of spinal arteriovenous fistulae.
description <h4>Purpose</h4>To determine the prevalence of spinal dural arteriovenous fistulae (SDAVF) in patients presenting with prominent vascular flow voids on imaging without other imaging findings suggestive of SDAVF.<h4>Methods</h4>We retrospectively identified patients from January 1, 2005 to March 1, 2012 who underwent spinal angiography for suspected SDAVF with prominent vascular flow voids on prior imaging. We excluded patients with other major spinal pathology or other imaging findings of SDAVF including cord hyperintensity, enhancement, or expansion. We calculated the proportion of patients with positive findings for SDAVF on angiography and evaluated the prevalence of SDAVF for this finding alone and in correlation with clinical findings.<h4>Results</h4>18 patients underwent spinal angiography for prominent flow voids on imaging without other spinal pathology or imaging findings of SDAVF. Three had a SDAVF detected on angiography. The prevalence of SDAVF in this population was low, only 17% (95% CI 6-39%). All of the patients with positive angiography findings had myelopathy, increasing the prevalence to 100% if the additional clinical finding of myelopathy was present.<h4>Conclusions</h4>Prominent flow voids without other imaging findings suggestive of SDAVF is poorly predictive of the presence of a SDAVF, unless myelopathy is present clinically.
format article
author Lea M Alhilali
Arich R Reynolds
Saeed Fakhran
author_facet Lea M Alhilali
Arich R Reynolds
Saeed Fakhran
author_sort Lea M Alhilali
title Value of prominent flow voids without cord edema in the detection of spinal arteriovenous fistulae.
title_short Value of prominent flow voids without cord edema in the detection of spinal arteriovenous fistulae.
title_full Value of prominent flow voids without cord edema in the detection of spinal arteriovenous fistulae.
title_fullStr Value of prominent flow voids without cord edema in the detection of spinal arteriovenous fistulae.
title_full_unstemmed Value of prominent flow voids without cord edema in the detection of spinal arteriovenous fistulae.
title_sort value of prominent flow voids without cord edema in the detection of spinal arteriovenous fistulae.
publisher Public Library of Science (PLoS)
publishDate 2014
url https://doaj.org/article/de05eee0cbb643da8c6aec0c005f4a45
work_keys_str_mv AT leamalhilali valueofprominentflowvoidswithoutcordedemainthedetectionofspinalarteriovenousfistulae
AT arichrreynolds valueofprominentflowvoidswithoutcordedemainthedetectionofspinalarteriovenousfistulae
AT saeedfakhran valueofprominentflowvoidswithoutcordedemainthedetectionofspinalarteriovenousfistulae
_version_ 1718422017190920192