Quantification of Differential Metabolites in Dried Blood Spots Using Second-Tier Testing for SCADD/IBDD Disorders Based on Large-Scale Newborn Screening in a Chinese Population

Background: Although newborn screening (NBS) for metabolic defects using the marker butyl carnitine (C4) combined with the C4-to-acetylcarnitine ratio is adequate, the incorporation of novel parameters may improve differential testing for these disorders without compromising sensitivity.Methods: Ana...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Wei Zhou, Heng Cai, Huizhong Li, Zhe Ji, Maosheng Gu
Formato: article
Lenguaje:EN
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://doaj.org/article/de0e0c024c484461b90e7ddf7779d15e
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:Background: Although newborn screening (NBS) for metabolic defects using the marker butyl carnitine (C4) combined with the C4-to-acetylcarnitine ratio is adequate, the incorporation of novel parameters may improve differential testing for these disorders without compromising sensitivity.Methods: Analytical and clinical performance was evaluated by MS/MS using 237 initially positive neonatal samples between March 2019 and March 2020 at the Newborn Screening Center of Xuzhou Maternity and Child Health Care Hospital. Additionally, second-tier testing by ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) combined with the quantification of ethylmalonate (EMA) or isobutyryl-glycine (IBG) in dried blood spots (DBSs) was performed to reduce the false-positive rate.Results: We reviewed initial MS/MS data for DBSs from 469,730 neonates, and a second-tier test was performed using 237 samples that exceeded the C4 concentration cutoff value. Eleven variants of the ACADS gene were identified, with c.1031A>G (p.E344G) being the most common. Fifteen ACAD8 mutations were identified in seven patients, and Swiss modeling and amino acid conservation analyses were conducted for the novel variants. Based on a retrospective analysis of EMA and IBG, the application of second-tier tests before the release of neonatal screening results reduced referrals by over 91.89% and improved the positive predictive value (PPV) for short-chain acyl-CoA dehydrogenase deficiency/isobutyryl-CoA dehydrogenase deficiency (SCADD/IBDD) screening.Conclusion: A screening algorithm including EMA/IBG improves target differential testing for NBS and may eliminate unnecessary referrals while maintaining 100% sensitivity. Second-tier screening using UPLC-MS/MS as a rapid and convenient supplemental DNA sequencing method may be beneficial for differential detection.