DETERMINING REFERENCE RANGES FOR TREC AND KREC ASSAYS IN IMMUNE DEFICIENCY SCREENING OF NEWBORNS IN RUSSIAN FEDERATION
In this work, we used a reference population of newborns and sampled dried blood spots on Guthrie cards of 2,739 individual samples to determine the reference intervals for TRECs and KRECs values, in order to diagnose primary immunodeficiency by means of neonatal screening. The median absolute value...
Guardado en:
Autores principales: | , , , , , , |
---|---|
Formato: | article |
Lenguaje: | RU |
Publicado: |
SPb RAACI
2019
|
Materias: | |
Acceso en línea: | https://doaj.org/article/de1469d591de4702887675e2b93ca48c |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:de1469d591de4702887675e2b93ca48c |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:de1469d591de4702887675e2b93ca48c2021-11-18T08:03:48ZDETERMINING REFERENCE RANGES FOR TREC AND KREC ASSAYS IN IMMUNE DEFICIENCY SCREENING OF NEWBORNS IN RUSSIAN FEDERATION1563-06252313-741X10.15789/1563-0625-2019-3-527-538https://doaj.org/article/de1469d591de4702887675e2b93ca48c2019-07-01T00:00:00Zhttps://www.mimmun.ru/mimmun/article/view/1826https://doaj.org/toc/1563-0625https://doaj.org/toc/2313-741XIn this work, we used a reference population of newborns and sampled dried blood spots on Guthrie cards of 2,739 individual samples to determine the reference intervals for TRECs and KRECs values, in order to diagnose primary immunodeficiency by means of neonatal screening. The median absolute values for TRECs and KRECs were 195 (CI95%: 185-206) and 185 (CI95%: 176-197) copies per μl, respectively; the normalized value for TRECs was 2780 (CI95%: 2690-2840), and for KRECs, 2790 (CI95%: 2700-2900) copies per 2 × 105 copies of the albumin gene or 105 cells. The reference interval was calculated for 99 and 99.9 percentiles of total TRECs and KRECs individual values. Due to asymmetric distribution of data, the outliers were filtered off, using the Tukey’s criterion applied after logarithmic transformation of the data. When analyzing absolute values for TREC/KREC (per μL of blood), no “drop-down” TRECs values were identified; for KRECs, 18 experimental values were excluded from further analysis (from 9.8 to 13.5). The outlying values were not identified among the normalized values of TRECs/KRECs. The obtained reference values for TRECs and KRECs (at the 0.1 percentile level) were, respectively, 458 and 32 per 105 cells, or 23 and 17 per μl of blood samples from neonates.M. A. GordukovaI. A. KorsunskyYu. V. ChursinovaM. M. ByakhovaI. P. OscorbinA. P. ProdeusM. L. FilipenkoSPb RAACIarticleprimary immunodeficiency (pid)t cellsb cellsscreeningtreckrecnewbornreference intervalsImmunologic diseases. AllergyRC581-607RUMedicinskaâ Immunologiâ, Vol 21, Iss 3, Pp 527-538 (2019) |
institution |
DOAJ |
collection |
DOAJ |
language |
RU |
topic |
primary immunodeficiency (pid) t cells b cells screening trec krec newborn reference intervals Immunologic diseases. Allergy RC581-607 |
spellingShingle |
primary immunodeficiency (pid) t cells b cells screening trec krec newborn reference intervals Immunologic diseases. Allergy RC581-607 M. A. Gordukova I. A. Korsunsky Yu. V. Chursinova M. M. Byakhova I. P. Oscorbin A. P. Prodeus M. L. Filipenko DETERMINING REFERENCE RANGES FOR TREC AND KREC ASSAYS IN IMMUNE DEFICIENCY SCREENING OF NEWBORNS IN RUSSIAN FEDERATION |
description |
In this work, we used a reference population of newborns and sampled dried blood spots on Guthrie cards of 2,739 individual samples to determine the reference intervals for TRECs and KRECs values, in order to diagnose primary immunodeficiency by means of neonatal screening. The median absolute values for TRECs and KRECs were 195 (CI95%: 185-206) and 185 (CI95%: 176-197) copies per μl, respectively; the normalized value for TRECs was 2780 (CI95%: 2690-2840), and for KRECs, 2790 (CI95%: 2700-2900) copies per 2 × 105 copies of the albumin gene or 105 cells. The reference interval was calculated for 99 and 99.9 percentiles of total TRECs and KRECs individual values. Due to asymmetric distribution of data, the outliers were filtered off, using the Tukey’s criterion applied after logarithmic transformation of the data. When analyzing absolute values for TREC/KREC (per μL of blood), no “drop-down” TRECs values were identified; for KRECs, 18 experimental values were excluded from further analysis (from 9.8 to 13.5). The outlying values were not identified among the normalized values of TRECs/KRECs. The obtained reference values for TRECs and KRECs (at the 0.1 percentile level) were, respectively, 458 and 32 per 105 cells, or 23 and 17 per μl of blood samples from neonates. |
format |
article |
author |
M. A. Gordukova I. A. Korsunsky Yu. V. Chursinova M. M. Byakhova I. P. Oscorbin A. P. Prodeus M. L. Filipenko |
author_facet |
M. A. Gordukova I. A. Korsunsky Yu. V. Chursinova M. M. Byakhova I. P. Oscorbin A. P. Prodeus M. L. Filipenko |
author_sort |
M. A. Gordukova |
title |
DETERMINING REFERENCE RANGES FOR TREC AND KREC ASSAYS IN IMMUNE DEFICIENCY SCREENING OF NEWBORNS IN RUSSIAN FEDERATION |
title_short |
DETERMINING REFERENCE RANGES FOR TREC AND KREC ASSAYS IN IMMUNE DEFICIENCY SCREENING OF NEWBORNS IN RUSSIAN FEDERATION |
title_full |
DETERMINING REFERENCE RANGES FOR TREC AND KREC ASSAYS IN IMMUNE DEFICIENCY SCREENING OF NEWBORNS IN RUSSIAN FEDERATION |
title_fullStr |
DETERMINING REFERENCE RANGES FOR TREC AND KREC ASSAYS IN IMMUNE DEFICIENCY SCREENING OF NEWBORNS IN RUSSIAN FEDERATION |
title_full_unstemmed |
DETERMINING REFERENCE RANGES FOR TREC AND KREC ASSAYS IN IMMUNE DEFICIENCY SCREENING OF NEWBORNS IN RUSSIAN FEDERATION |
title_sort |
determining reference ranges for trec and krec assays in immune deficiency screening of newborns in russian federation |
publisher |
SPb RAACI |
publishDate |
2019 |
url |
https://doaj.org/article/de1469d591de4702887675e2b93ca48c |
work_keys_str_mv |
AT magordukova determiningreferencerangesfortrecandkrecassaysinimmunedeficiencyscreeningofnewbornsinrussianfederation AT iakorsunsky determiningreferencerangesfortrecandkrecassaysinimmunedeficiencyscreeningofnewbornsinrussianfederation AT yuvchursinova determiningreferencerangesfortrecandkrecassaysinimmunedeficiencyscreeningofnewbornsinrussianfederation AT mmbyakhova determiningreferencerangesfortrecandkrecassaysinimmunedeficiencyscreeningofnewbornsinrussianfederation AT iposcorbin determiningreferencerangesfortrecandkrecassaysinimmunedeficiencyscreeningofnewbornsinrussianfederation AT approdeus determiningreferencerangesfortrecandkrecassaysinimmunedeficiencyscreeningofnewbornsinrussianfederation AT mlfilipenko determiningreferencerangesfortrecandkrecassaysinimmunedeficiencyscreeningofnewbornsinrussianfederation |
_version_ |
1718422386558107648 |