Thermal-strength analysis of a cross-flow heat exchanger and its design improvement

After a year of the heat exchanger operation in overload conditions, a number of cracks on the tube connections to the tubesheet have been observed. To explain the stress concentration and crack initiation, a finite element analysis is performed. A three-dimensional model is constructed and analyzed...

Description complète

Enregistré dans:
Détails bibliographiques
Auteurs principaux: Konieczny Mariusz, Felkowski Łukasz
Format: article
Langue:EN
Publié: De Gruyter 2021
Sujets:
Accès en ligne:https://doaj.org/article/de81f8627d7f41489ff4eb62e57486df
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
Description
Résumé:After a year of the heat exchanger operation in overload conditions, a number of cracks on the tube connections to the tubesheet have been observed. To explain the stress concentration and crack initiation, a finite element analysis is performed. A three-dimensional model is constructed and analyzed. To calculate more precisely the state of stress in the most loaded regions, a submodel is created. The maximum stress exceeds the allowable stress, and according to the standards, it can lead to ratcheting. To reduce stress concentration, all tubes should be shortened and corrugated tubes are installed in the high-temperature region from the side of the burner. A finite element model of the modified heat exchanger and a submodel are created. In the modified heat exchanger, ratcheting should not occur according to the applied standards. During the operation of the modified heat exchanger, there are no further problems with cracking.