Selection of a workpiece clamping system for computer-aided subtractive manufacturing of geometrically complex medical models

Physical models of anatomical structures can be made using Additive Manufacturing (AM) or Subtractive Manufacturing (SM). The advantage of subtractive techniques over additive ones is the possibility of maintaining the homogeneity and consistency of the processed material, which is extremely importa...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Wojnarowska Wiktoria, Kwolek Maciej, Miechowicz Sławomir
Formato: article
Lenguaje:EN
Publicado: De Gruyter 2021
Materias:
cnc
Acceso en línea:https://doaj.org/article/df4e9c5c32ea420a84d34cf8f450e605
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:df4e9c5c32ea420a84d34cf8f450e605
record_format dspace
spelling oai:doaj.org-article:df4e9c5c32ea420a84d34cf8f450e6052021-12-05T14:10:46ZSelection of a workpiece clamping system for computer-aided subtractive manufacturing of geometrically complex medical models2391-543910.1515/eng-2021-0026https://doaj.org/article/df4e9c5c32ea420a84d34cf8f450e6052021-01-01T00:00:00Zhttps://doi.org/10.1515/eng-2021-0026https://doaj.org/toc/2391-5439Physical models of anatomical structures can be made using Additive Manufacturing (AM) or Subtractive Manufacturing (SM). The advantage of subtractive techniques over additive ones is the possibility of maintaining the homogeneity and consistency of the processed material, which is extremely important in the case of medical devices. Currently, a geometrically complex medical model can be made even on a simple, 3-axis CNC machine tool. However, often the semi-finished product must be machined in at least two clamping configurations. The aim of the work is to present the method of fixing a workpiece in the process of subtractive production of geometrically complex medical objects on the example of skull bone prostheses. The paper discusses the use of two clamping systems for machining such models. It presents the process of subtractive production of bone prostheses models fitted to the defect of the skull bone with the use of the proposed methods of fixing the workpiece. The result of the work are two models of the skull bone prosthesis. A more complex model was analysed in terms of the accuracy of geometry reproduction. The research confirmed the usefulness of the proposed clamping systems for the preparation of medical models of geometrically complex anatomical structures.Wojnarowska WiktoriaKwolek MaciejMiechowicz SławomirDe GruyterarticlecnccranioplastyimplantmachiningprosthesisEngineering (General). Civil engineering (General)TA1-2040ENOpen Engineering, Vol 11, Iss 1, Pp 239-248 (2021)
institution DOAJ
collection DOAJ
language EN
topic cnc
cranioplasty
implant
machining
prosthesis
Engineering (General). Civil engineering (General)
TA1-2040
spellingShingle cnc
cranioplasty
implant
machining
prosthesis
Engineering (General). Civil engineering (General)
TA1-2040
Wojnarowska Wiktoria
Kwolek Maciej
Miechowicz Sławomir
Selection of a workpiece clamping system for computer-aided subtractive manufacturing of geometrically complex medical models
description Physical models of anatomical structures can be made using Additive Manufacturing (AM) or Subtractive Manufacturing (SM). The advantage of subtractive techniques over additive ones is the possibility of maintaining the homogeneity and consistency of the processed material, which is extremely important in the case of medical devices. Currently, a geometrically complex medical model can be made even on a simple, 3-axis CNC machine tool. However, often the semi-finished product must be machined in at least two clamping configurations. The aim of the work is to present the method of fixing a workpiece in the process of subtractive production of geometrically complex medical objects on the example of skull bone prostheses. The paper discusses the use of two clamping systems for machining such models. It presents the process of subtractive production of bone prostheses models fitted to the defect of the skull bone with the use of the proposed methods of fixing the workpiece. The result of the work are two models of the skull bone prosthesis. A more complex model was analysed in terms of the accuracy of geometry reproduction. The research confirmed the usefulness of the proposed clamping systems for the preparation of medical models of geometrically complex anatomical structures.
format article
author Wojnarowska Wiktoria
Kwolek Maciej
Miechowicz Sławomir
author_facet Wojnarowska Wiktoria
Kwolek Maciej
Miechowicz Sławomir
author_sort Wojnarowska Wiktoria
title Selection of a workpiece clamping system for computer-aided subtractive manufacturing of geometrically complex medical models
title_short Selection of a workpiece clamping system for computer-aided subtractive manufacturing of geometrically complex medical models
title_full Selection of a workpiece clamping system for computer-aided subtractive manufacturing of geometrically complex medical models
title_fullStr Selection of a workpiece clamping system for computer-aided subtractive manufacturing of geometrically complex medical models
title_full_unstemmed Selection of a workpiece clamping system for computer-aided subtractive manufacturing of geometrically complex medical models
title_sort selection of a workpiece clamping system for computer-aided subtractive manufacturing of geometrically complex medical models
publisher De Gruyter
publishDate 2021
url https://doaj.org/article/df4e9c5c32ea420a84d34cf8f450e605
work_keys_str_mv AT wojnarowskawiktoria selectionofaworkpiececlampingsystemforcomputeraidedsubtractivemanufacturingofgeometricallycomplexmedicalmodels
AT kwolekmaciej selectionofaworkpiececlampingsystemforcomputeraidedsubtractivemanufacturingofgeometricallycomplexmedicalmodels
AT miechowiczsławomir selectionofaworkpiececlampingsystemforcomputeraidedsubtractivemanufacturingofgeometricallycomplexmedicalmodels
_version_ 1718371748633640960