Effect of Light-Sources and Thicknesses of Composite Onlays on Micro-Hardness of Luting Composites

The aim of this study was to compare three different light-curing-units (LCUs) and determine their effectiveness in the adhesive cementation of indirect composite restorations when a light-curing resin cement is used. Two resin composites were selected: Enamel Plus HRI (Micerium) and AURA (SDI). Thr...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Francesco De Angelis, Mirco Vadini, Mario Capogreco, Camillo D’Arcangelo, Maurizio D’Amario
Formato: article
Lenguaje:EN
Publicado: MDPI AG 2021
Materias:
T
Acceso en línea:https://doaj.org/article/df9b3183394e4282af3de969fc01791d
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:The aim of this study was to compare three different light-curing-units (LCUs) and determine their effectiveness in the adhesive cementation of indirect composite restorations when a light-curing resin cement is used. Two resin composites were selected: Enamel Plus HRI (Micerium) and AURA (SDI). Three thicknesses (3 mm, 4 mm and 5 mm) were produced and applied as overlays and underlays for each resin composite. A standardized composite layer was placed between underlay and overlay surfaces. Light curing of the resin-based luting composites was attained through the overlay filters using LCUs for different exposure times. All specimens were allocated to experimental groups according to the overlay thickness, curing unit and curing time. Vickers Hardness (VH) notches were carried out on each specimen. Data were statistically evaluated. The curing unit, curing time and overlay thickness were significant factors capable of influencing VH values. The results showed significantly decreased VH values with increasing specimen thickness (<i>p</i> < 0.05). Significant differences in VH values were found amongst the LCUs for the various exposure times (<i>p</i> < 0.05). According to the results, a time of cure shorter than 80 s (with a conventional quartz–tungsten–halogen LCU) or shorter than 40 s (with a high-power light-emitting diode (LED) LCU) is not recommended. The only subgroup achieving clinically acceptable VH values after a short 20 s curing time included the 3 mm-thick overlays made out of the AURA composite, when the high-power LED LCU unit was used (VH 51.0). Composite thickness has an intense effect on polymerization. In clinical practice, light-cured resin cements may result in insufficient polymerization for high thickness and inadequate times. High-intensity curing lights can attain the sufficient polymerization of resin cements through overlays in a significantly shorter time than conventional halogen light.