DETERMINATION OF PULSATION FACTORS OF THE SYSTEM OF SUPPRESSION OF INTERFERING HARMONICS OF A SEMICONDUCTOR CONVERTER

Purpose. The purpose of the paper is to define the pulsation factors of a closed-loop automatic control system (ACS) of interfering harmonics containing a semiconductor converter with double-sided pulse-width modulation (PWM), as well as confirmation of theoretical assumptions about possibilities of...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: V. V. Panchenko, A. S. Maslii, D. P. Pomazan, S. G. Buriakovskyi
Formato: article
Lenguaje:EN
RU
UK
Publicado: National Technical University "Kharkiv Polytechnic Institute" 2018
Materias:
Acceso en línea:https://doaj.org/article/e00955b2585f437c9cd34b95aca6e42d
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:e00955b2585f437c9cd34b95aca6e42d
record_format dspace
spelling oai:doaj.org-article:e00955b2585f437c9cd34b95aca6e42d2021-12-02T14:30:26ZDETERMINATION OF PULSATION FACTORS OF THE SYSTEM OF SUPPRESSION OF INTERFERING HARMONICS OF A SEMICONDUCTOR CONVERTER10.20998/2074-272X.2018.4.042074-272X2309-3404https://doaj.org/article/e00955b2585f437c9cd34b95aca6e42d2018-08-01T00:00:00Zhttp://eie.khpi.edu.ua/article/view/2074-272X.2018.4.04/137624https://doaj.org/toc/2074-272Xhttps://doaj.org/toc/2309-3404Purpose. The purpose of the paper is to define the pulsation factors of a closed-loop automatic control system (ACS) of interfering harmonics containing a semiconductor converter with double-sided pulse-width modulation (PWM), as well as confirmation of theoretical assumptions about possibilities of self-compensation of pulsation factors’ influence in the system with double-sided PWM. Methodology. The research was conducted with the usage of classic electric circuit theory, frequency analysis methods, generalized function theory. Results. The obtained expressions mathematically relate pulsation factors, value of the damping coefficient and manipulative variable for different frequencies of interfering harmonics in the system with double-sided PWM. The research concerned harmonics with frequencies 100, 300, 600, 900 and 1200 Hz as the most significant constituents of the output voltage of a 12-pulse semiconductor converter. The obtained expressions allow taking into account settings of the selective link and its approximation on the level of supreme frequencies with aperiodic link. Originality. The research has experimentally proved theoretical assumptions about self-compensation of pulsation factors in the system with double-sided PWM. It has been shown that the damping coefficient has a low-impact influence on the values of pulsation factors. It is caused by the pass band of the selective link, which is included in the closed-loop control system of harmonics regulation. Practical value. Application of the research results can contribute to the development of the closed-loop control system for effective attenuation of interfering harmonics in direct current contact wire without interfering in the power part of the semiconductor converter. Besides the possibility to regulate output voltage, it will also help to solve the problem of electromagnetic compatibility of a traction substation semiconductor converter with contact wire. The application of the developed closed-loop control system will as well provide for decreasing the size of the filter in the direct current traction substation unit.V. V. PanchenkoA. S. MasliiD. P. PomazanS. G. Buriakovskyi National Technical University "Kharkiv Polytechnic Institute"articlepulsation factorinterfering harmonicautomatic control systemdouble-sided pulse-width modulationsemiconductor converterElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENRUUKElectrical engineering & Electromechanics, Iss 4, Pp 24-28 (2018)
institution DOAJ
collection DOAJ
language EN
RU
UK
topic pulsation factor
interfering harmonic
automatic control system
double-sided pulse-width modulation
semiconductor converter
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
spellingShingle pulsation factor
interfering harmonic
automatic control system
double-sided pulse-width modulation
semiconductor converter
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
V. V. Panchenko
A. S. Maslii
D. P. Pomazan
S. G. Buriakovskyi
DETERMINATION OF PULSATION FACTORS OF THE SYSTEM OF SUPPRESSION OF INTERFERING HARMONICS OF A SEMICONDUCTOR CONVERTER
description Purpose. The purpose of the paper is to define the pulsation factors of a closed-loop automatic control system (ACS) of interfering harmonics containing a semiconductor converter with double-sided pulse-width modulation (PWM), as well as confirmation of theoretical assumptions about possibilities of self-compensation of pulsation factors’ influence in the system with double-sided PWM. Methodology. The research was conducted with the usage of classic electric circuit theory, frequency analysis methods, generalized function theory. Results. The obtained expressions mathematically relate pulsation factors, value of the damping coefficient and manipulative variable for different frequencies of interfering harmonics in the system with double-sided PWM. The research concerned harmonics with frequencies 100, 300, 600, 900 and 1200 Hz as the most significant constituents of the output voltage of a 12-pulse semiconductor converter. The obtained expressions allow taking into account settings of the selective link and its approximation on the level of supreme frequencies with aperiodic link. Originality. The research has experimentally proved theoretical assumptions about self-compensation of pulsation factors in the system with double-sided PWM. It has been shown that the damping coefficient has a low-impact influence on the values of pulsation factors. It is caused by the pass band of the selective link, which is included in the closed-loop control system of harmonics regulation. Practical value. Application of the research results can contribute to the development of the closed-loop control system for effective attenuation of interfering harmonics in direct current contact wire without interfering in the power part of the semiconductor converter. Besides the possibility to regulate output voltage, it will also help to solve the problem of electromagnetic compatibility of a traction substation semiconductor converter with contact wire. The application of the developed closed-loop control system will as well provide for decreasing the size of the filter in the direct current traction substation unit.
format article
author V. V. Panchenko
A. S. Maslii
D. P. Pomazan
S. G. Buriakovskyi
author_facet V. V. Panchenko
A. S. Maslii
D. P. Pomazan
S. G. Buriakovskyi
author_sort V. V. Panchenko
title DETERMINATION OF PULSATION FACTORS OF THE SYSTEM OF SUPPRESSION OF INTERFERING HARMONICS OF A SEMICONDUCTOR CONVERTER
title_short DETERMINATION OF PULSATION FACTORS OF THE SYSTEM OF SUPPRESSION OF INTERFERING HARMONICS OF A SEMICONDUCTOR CONVERTER
title_full DETERMINATION OF PULSATION FACTORS OF THE SYSTEM OF SUPPRESSION OF INTERFERING HARMONICS OF A SEMICONDUCTOR CONVERTER
title_fullStr DETERMINATION OF PULSATION FACTORS OF THE SYSTEM OF SUPPRESSION OF INTERFERING HARMONICS OF A SEMICONDUCTOR CONVERTER
title_full_unstemmed DETERMINATION OF PULSATION FACTORS OF THE SYSTEM OF SUPPRESSION OF INTERFERING HARMONICS OF A SEMICONDUCTOR CONVERTER
title_sort determination of pulsation factors of the system of suppression of interfering harmonics of a semiconductor converter
publisher National Technical University "Kharkiv Polytechnic Institute"
publishDate 2018
url https://doaj.org/article/e00955b2585f437c9cd34b95aca6e42d
work_keys_str_mv AT vvpanchenko determinationofpulsationfactorsofthesystemofsuppressionofinterferingharmonicsofasemiconductorconverter
AT asmaslii determinationofpulsationfactorsofthesystemofsuppressionofinterferingharmonicsofasemiconductorconverter
AT dppomazan determinationofpulsationfactorsofthesystemofsuppressionofinterferingharmonicsofasemiconductorconverter
AT sgburiakovskyi determinationofpulsationfactorsofthesystemofsuppressionofinterferingharmonicsofasemiconductorconverter
_version_ 1718391221750071296