Understanding TAVR device expansion as it relates to morphology of the bicuspid aortic valve: A simulation study.

The bicuspid aortic valve (BAV) is a common and heterogeneous congenital heart abnormality that is often complicated by aortic stenosis. Although initially developed for tricuspid aortic valves (TAV), transcatheter aortic valve replacement (TAVR) devices are increasingly applied to the treatment of...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Jonathan Kusner, Giulia Luraghi, Farhan Khodaee, José Félix Rodriguez Matas, Francesco Migliavacca, Elazer R Edelman, Farhad R Nezami
Formato: article
Lenguaje:EN
Publicado: Public Library of Science (PLoS) 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/e1430077fdeb4b6dbe8db8d48cdc7be2
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:e1430077fdeb4b6dbe8db8d48cdc7be2
record_format dspace
spelling oai:doaj.org-article:e1430077fdeb4b6dbe8db8d48cdc7be22021-11-25T05:54:15ZUnderstanding TAVR device expansion as it relates to morphology of the bicuspid aortic valve: A simulation study.1932-620310.1371/journal.pone.0251579https://doaj.org/article/e1430077fdeb4b6dbe8db8d48cdc7be22021-01-01T00:00:00Zhttps://doi.org/10.1371/journal.pone.0251579https://doaj.org/toc/1932-6203The bicuspid aortic valve (BAV) is a common and heterogeneous congenital heart abnormality that is often complicated by aortic stenosis. Although initially developed for tricuspid aortic valves (TAV), transcatheter aortic valve replacement (TAVR) devices are increasingly applied to the treatment of BAV stenosis. It is known that patient-device relationship between TAVR and BAV are not equivalent to those observed in TAV but the nature of these differences are not well understood. We sought to better understand the patient-device relationships between TAVR devices and the two most common morphologies of BAV. We performed finite element simulation of TAVR deployment into three cases of idealized aortic anatomies (TAV, Sievers 0 BAV, Sievers 1 BAV), derived from patient-specific measurements. Valve leaflet von Mises stress at the aortic commissures differed by valve configuration over a ten-fold range (TAV: 0.55 MPa, Sievers 0: 6.64 MPa, and Sievers 1: 4.19 MPa). First principle stress on the aortic wall was greater in Sievers 1 (0.316 MPa) and Sievers 0 BAV (0.137 MPa) compared to TAV (0.056 MPa). TAVR placement in Sievers 1 BAV demonstrated significant device asymmetric alignment, with 1.09 mm of displacement between the center of the device measured at the annulus and at the leaflet free edge. This orifice displacement was marginal in TAV (0.33 mm) and even lower in Sievers 0 BAV (0.23 mm). BAV TAVR, depending on the subtype involved, may encounter disparate combinations of device under expansion and asymmetry compared to TAV deployment. Understanding the impacts of BAV morphology on patient-device relationships can help improve device selection, patient eligibility, and the overall safety of TAVR in BAV.Jonathan KusnerGiulia LuraghiFarhan KhodaeeJosé Félix Rodriguez MatasFrancesco MigliavaccaElazer R EdelmanFarhad R NezamiPublic Library of Science (PLoS)articleMedicineRScienceQENPLoS ONE, Vol 16, Iss 5, p e0251579 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Jonathan Kusner
Giulia Luraghi
Farhan Khodaee
José Félix Rodriguez Matas
Francesco Migliavacca
Elazer R Edelman
Farhad R Nezami
Understanding TAVR device expansion as it relates to morphology of the bicuspid aortic valve: A simulation study.
description The bicuspid aortic valve (BAV) is a common and heterogeneous congenital heart abnormality that is often complicated by aortic stenosis. Although initially developed for tricuspid aortic valves (TAV), transcatheter aortic valve replacement (TAVR) devices are increasingly applied to the treatment of BAV stenosis. It is known that patient-device relationship between TAVR and BAV are not equivalent to those observed in TAV but the nature of these differences are not well understood. We sought to better understand the patient-device relationships between TAVR devices and the two most common morphologies of BAV. We performed finite element simulation of TAVR deployment into three cases of idealized aortic anatomies (TAV, Sievers 0 BAV, Sievers 1 BAV), derived from patient-specific measurements. Valve leaflet von Mises stress at the aortic commissures differed by valve configuration over a ten-fold range (TAV: 0.55 MPa, Sievers 0: 6.64 MPa, and Sievers 1: 4.19 MPa). First principle stress on the aortic wall was greater in Sievers 1 (0.316 MPa) and Sievers 0 BAV (0.137 MPa) compared to TAV (0.056 MPa). TAVR placement in Sievers 1 BAV demonstrated significant device asymmetric alignment, with 1.09 mm of displacement between the center of the device measured at the annulus and at the leaflet free edge. This orifice displacement was marginal in TAV (0.33 mm) and even lower in Sievers 0 BAV (0.23 mm). BAV TAVR, depending on the subtype involved, may encounter disparate combinations of device under expansion and asymmetry compared to TAV deployment. Understanding the impacts of BAV morphology on patient-device relationships can help improve device selection, patient eligibility, and the overall safety of TAVR in BAV.
format article
author Jonathan Kusner
Giulia Luraghi
Farhan Khodaee
José Félix Rodriguez Matas
Francesco Migliavacca
Elazer R Edelman
Farhad R Nezami
author_facet Jonathan Kusner
Giulia Luraghi
Farhan Khodaee
José Félix Rodriguez Matas
Francesco Migliavacca
Elazer R Edelman
Farhad R Nezami
author_sort Jonathan Kusner
title Understanding TAVR device expansion as it relates to morphology of the bicuspid aortic valve: A simulation study.
title_short Understanding TAVR device expansion as it relates to morphology of the bicuspid aortic valve: A simulation study.
title_full Understanding TAVR device expansion as it relates to morphology of the bicuspid aortic valve: A simulation study.
title_fullStr Understanding TAVR device expansion as it relates to morphology of the bicuspid aortic valve: A simulation study.
title_full_unstemmed Understanding TAVR device expansion as it relates to morphology of the bicuspid aortic valve: A simulation study.
title_sort understanding tavr device expansion as it relates to morphology of the bicuspid aortic valve: a simulation study.
publisher Public Library of Science (PLoS)
publishDate 2021
url https://doaj.org/article/e1430077fdeb4b6dbe8db8d48cdc7be2
work_keys_str_mv AT jonathankusner understandingtavrdeviceexpansionasitrelatestomorphologyofthebicuspidaorticvalveasimulationstudy
AT giulialuraghi understandingtavrdeviceexpansionasitrelatestomorphologyofthebicuspidaorticvalveasimulationstudy
AT farhankhodaee understandingtavrdeviceexpansionasitrelatestomorphologyofthebicuspidaorticvalveasimulationstudy
AT josefelixrodriguezmatas understandingtavrdeviceexpansionasitrelatestomorphologyofthebicuspidaorticvalveasimulationstudy
AT francescomigliavacca understandingtavrdeviceexpansionasitrelatestomorphologyofthebicuspidaorticvalveasimulationstudy
AT elazerredelman understandingtavrdeviceexpansionasitrelatestomorphologyofthebicuspidaorticvalveasimulationstudy
AT farhadrnezami understandingtavrdeviceexpansionasitrelatestomorphologyofthebicuspidaorticvalveasimulationstudy
_version_ 1718414432627851264