Tissue effects in vessel sealing and transection from an ultrasonic device with more intelligent control of energy delivery
Duan Broughton,1 Alissa L Welling,1 Emily H Monroe,1 Kristen Pirozzi,2 John B Schulte,1 Jeffrey W Clymer1 1Ethicon Endo-Surgery, Inc., Cincinnati, OH, 2University of Central Florida, Orlando, FL, USA Background: Ultrasonic surgical devices have been demonstrated to provide excellent hemostasis, effi...
Guardado en:
Autores principales: | , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2013
|
Materias: | |
Acceso en línea: | https://doaj.org/article/e2692bc6f7294b758d6d33e1781c9393 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:e2692bc6f7294b758d6d33e1781c9393 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:e2692bc6f7294b758d6d33e1781c93932021-12-02T02:43:52ZTissue effects in vessel sealing and transection from an ultrasonic device with more intelligent control of energy delivery1179-1470https://doaj.org/article/e2692bc6f7294b758d6d33e1781c93932013-09-01T00:00:00Zhttp://www.dovepress.com/tissue-effects-in-vessel-sealing-and-transection-from-an-ultrasonic-de-a14368https://doaj.org/toc/1179-1470Duan Broughton,1 Alissa L Welling,1 Emily H Monroe,1 Kristen Pirozzi,2 John B Schulte,1 Jeffrey W Clymer1 1Ethicon Endo-Surgery, Inc., Cincinnati, OH, 2University of Central Florida, Orlando, FL, USA Background: Ultrasonic surgical devices have been demonstrated to provide excellent hemostasis, efficient transection, minimal lateral thermal damage, low smoke generation, and no risk of electrical current passage to the patient. These benefits originate from the inherent characteristics of the ultrasonic mechanism, but further improvements were thought possible through optimization of the energy delivery during application. The study reported here compared a new ultrasonic device, Harmonic ACE®+ Shears with Adaptive Tissue Technology, with a commercial predicate device, Harmonic ACE® Shears (both Ethicon Endo-Surgery, Inc., Cincinnati, OH, USA). Methods: Devices were evaluated in an in vivo porcine model intraoperatively and after a 30-day survival period. Both devices were used to seal a variety of vessels 1–5 mm in diameter, and compared for hemostasis, histological thermal damage, and adhesion formation. Sealed vessels were evaluated ex vivo for burst pressure, and visual obstruction caused by plumage from device application was assessed quantitatively. Results: ACE+ produced significantly less thermal damage, had fewer adhesions, offered faster transection, involved less visual obstruction, and had higher burst pressures than the predicate device. All vessel seals, evaluated over the course of a 30-day survival period in pigs, remained intact. Conclusion: The new Adaptive Tissue Technology algorithm assists the surgeon in achieving better control of energy delivery to the tissue, sealing vessels with supra-physiological burst pressures, and low thermal damage. These preclinical results with Harmonic ACE+ may translate into meaningful clinical benefits, providing greater precision along with more efficient and effective cutting and coagulation in open or laparoscopic procedures. Keywords: ultrasonic, Harmonic, ACE, vessel sealing, burst pressure, adhesions, Adaptive Tissue TechnologyBroughton DWelling ALMonroe EHPirozzi KSchulte JBClymer JWDove Medical PressarticleMedical technologyR855-855.5ENMedical Devices: Evidence and Research, Vol 2013, Iss default, Pp 151-154 (2013) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medical technology R855-855.5 |
spellingShingle |
Medical technology R855-855.5 Broughton D Welling AL Monroe EH Pirozzi K Schulte JB Clymer JW Tissue effects in vessel sealing and transection from an ultrasonic device with more intelligent control of energy delivery |
description |
Duan Broughton,1 Alissa L Welling,1 Emily H Monroe,1 Kristen Pirozzi,2 John B Schulte,1 Jeffrey W Clymer1 1Ethicon Endo-Surgery, Inc., Cincinnati, OH, 2University of Central Florida, Orlando, FL, USA Background: Ultrasonic surgical devices have been demonstrated to provide excellent hemostasis, efficient transection, minimal lateral thermal damage, low smoke generation, and no risk of electrical current passage to the patient. These benefits originate from the inherent characteristics of the ultrasonic mechanism, but further improvements were thought possible through optimization of the energy delivery during application. The study reported here compared a new ultrasonic device, Harmonic ACE®+ Shears with Adaptive Tissue Technology, with a commercial predicate device, Harmonic ACE® Shears (both Ethicon Endo-Surgery, Inc., Cincinnati, OH, USA). Methods: Devices were evaluated in an in vivo porcine model intraoperatively and after a 30-day survival period. Both devices were used to seal a variety of vessels 1–5 mm in diameter, and compared for hemostasis, histological thermal damage, and adhesion formation. Sealed vessels were evaluated ex vivo for burst pressure, and visual obstruction caused by plumage from device application was assessed quantitatively. Results: ACE+ produced significantly less thermal damage, had fewer adhesions, offered faster transection, involved less visual obstruction, and had higher burst pressures than the predicate device. All vessel seals, evaluated over the course of a 30-day survival period in pigs, remained intact. Conclusion: The new Adaptive Tissue Technology algorithm assists the surgeon in achieving better control of energy delivery to the tissue, sealing vessels with supra-physiological burst pressures, and low thermal damage. These preclinical results with Harmonic ACE+ may translate into meaningful clinical benefits, providing greater precision along with more efficient and effective cutting and coagulation in open or laparoscopic procedures. Keywords: ultrasonic, Harmonic, ACE, vessel sealing, burst pressure, adhesions, Adaptive Tissue Technology |
format |
article |
author |
Broughton D Welling AL Monroe EH Pirozzi K Schulte JB Clymer JW |
author_facet |
Broughton D Welling AL Monroe EH Pirozzi K Schulte JB Clymer JW |
author_sort |
Broughton D |
title |
Tissue effects in vessel sealing and transection from an ultrasonic device with more intelligent control of energy delivery |
title_short |
Tissue effects in vessel sealing and transection from an ultrasonic device with more intelligent control of energy delivery |
title_full |
Tissue effects in vessel sealing and transection from an ultrasonic device with more intelligent control of energy delivery |
title_fullStr |
Tissue effects in vessel sealing and transection from an ultrasonic device with more intelligent control of energy delivery |
title_full_unstemmed |
Tissue effects in vessel sealing and transection from an ultrasonic device with more intelligent control of energy delivery |
title_sort |
tissue effects in vessel sealing and transection from an ultrasonic device with more intelligent control of energy delivery |
publisher |
Dove Medical Press |
publishDate |
2013 |
url |
https://doaj.org/article/e2692bc6f7294b758d6d33e1781c9393 |
work_keys_str_mv |
AT broughtond tissueeffectsinvesselsealingandtransectionfromanultrasonicdevicewithmoreintelligentcontrolofenergydelivery AT wellingal tissueeffectsinvesselsealingandtransectionfromanultrasonicdevicewithmoreintelligentcontrolofenergydelivery AT monroeeh tissueeffectsinvesselsealingandtransectionfromanultrasonicdevicewithmoreintelligentcontrolofenergydelivery AT pirozzik tissueeffectsinvesselsealingandtransectionfromanultrasonicdevicewithmoreintelligentcontrolofenergydelivery AT schultejb tissueeffectsinvesselsealingandtransectionfromanultrasonicdevicewithmoreintelligentcontrolofenergydelivery AT clymerjw tissueeffectsinvesselsealingandtransectionfromanultrasonicdevicewithmoreintelligentcontrolofenergydelivery |
_version_ |
1718402255554609152 |