A fluorescence immunoassay for a rapid detection of Listeria monocytogenes on working surfaces

Abstract Listeria monocytogenes is a foodborne pathogen responsible for human listeriosis. The increasing incidence of listeriosis induced governments and food manufacturing enterprises to act to diminish the problem. Several methods for the detection of Listeria monocytogenes in food industries wer...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Alessandro Capo, Sabato D’Auria, Monique Lacroix
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2020
Materias:
R
Q
Acceso en línea:https://doaj.org/article/e2a24932ace74d93914ff7dd5380544d
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:e2a24932ace74d93914ff7dd5380544d
record_format dspace
spelling oai:doaj.org-article:e2a24932ace74d93914ff7dd5380544d2021-12-02T12:33:14ZA fluorescence immunoassay for a rapid detection of Listeria monocytogenes on working surfaces10.1038/s41598-020-77747-y2045-2322https://doaj.org/article/e2a24932ace74d93914ff7dd5380544d2020-12-01T00:00:00Zhttps://doi.org/10.1038/s41598-020-77747-yhttps://doaj.org/toc/2045-2322Abstract Listeria monocytogenes is a foodborne pathogen responsible for human listeriosis. The increasing incidence of listeriosis induced governments and food manufacturing enterprises to act to diminish the problem. Several methods for the detection of Listeria monocytogenes in food industries were developed. However, they are time-consuming and require the use of specialized equipment. To reduce the detection time of Listeria monocytogenes in food, in this work we developed a fluorescence sandwich immunoassay based on the use of an innovative chitosan-cellulose nanocrystal (CNC) membrane that improves the antigen capture during bacterial growth. The combined use of CNC film for the capture of p60 protein-specific antigen together with the use of fluorescence detection reduced the time of analysis from 24 to 12 h with a limit of detection (LOD) of the assay of 102 CFU/mL (2 Log). In addition, the use of monoclonal anti-PepD covalently immobilized to a CNC membrane assured a high specificity of the assay. Interestingly, the obtained results show no cross-reactivity with the five most diffused pathogen bacteria strains tested.Alessandro CapoSabato D’AuriaMonique LacroixNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 10, Iss 1, Pp 1-12 (2020)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Alessandro Capo
Sabato D’Auria
Monique Lacroix
A fluorescence immunoassay for a rapid detection of Listeria monocytogenes on working surfaces
description Abstract Listeria monocytogenes is a foodborne pathogen responsible for human listeriosis. The increasing incidence of listeriosis induced governments and food manufacturing enterprises to act to diminish the problem. Several methods for the detection of Listeria monocytogenes in food industries were developed. However, they are time-consuming and require the use of specialized equipment. To reduce the detection time of Listeria monocytogenes in food, in this work we developed a fluorescence sandwich immunoassay based on the use of an innovative chitosan-cellulose nanocrystal (CNC) membrane that improves the antigen capture during bacterial growth. The combined use of CNC film for the capture of p60 protein-specific antigen together with the use of fluorescence detection reduced the time of analysis from 24 to 12 h with a limit of detection (LOD) of the assay of 102 CFU/mL (2 Log). In addition, the use of monoclonal anti-PepD covalently immobilized to a CNC membrane assured a high specificity of the assay. Interestingly, the obtained results show no cross-reactivity with the five most diffused pathogen bacteria strains tested.
format article
author Alessandro Capo
Sabato D’Auria
Monique Lacroix
author_facet Alessandro Capo
Sabato D’Auria
Monique Lacroix
author_sort Alessandro Capo
title A fluorescence immunoassay for a rapid detection of Listeria monocytogenes on working surfaces
title_short A fluorescence immunoassay for a rapid detection of Listeria monocytogenes on working surfaces
title_full A fluorescence immunoassay for a rapid detection of Listeria monocytogenes on working surfaces
title_fullStr A fluorescence immunoassay for a rapid detection of Listeria monocytogenes on working surfaces
title_full_unstemmed A fluorescence immunoassay for a rapid detection of Listeria monocytogenes on working surfaces
title_sort fluorescence immunoassay for a rapid detection of listeria monocytogenes on working surfaces
publisher Nature Portfolio
publishDate 2020
url https://doaj.org/article/e2a24932ace74d93914ff7dd5380544d
work_keys_str_mv AT alessandrocapo afluorescenceimmunoassayforarapiddetectionoflisteriamonocytogenesonworkingsurfaces
AT sabatodauria afluorescenceimmunoassayforarapiddetectionoflisteriamonocytogenesonworkingsurfaces
AT moniquelacroix afluorescenceimmunoassayforarapiddetectionoflisteriamonocytogenesonworkingsurfaces
AT alessandrocapo fluorescenceimmunoassayforarapiddetectionoflisteriamonocytogenesonworkingsurfaces
AT sabatodauria fluorescenceimmunoassayforarapiddetectionoflisteriamonocytogenesonworkingsurfaces
AT moniquelacroix fluorescenceimmunoassayforarapiddetectionoflisteriamonocytogenesonworkingsurfaces
_version_ 1718393891008282624