Experimental methodology for bubble content measurement of thin films
The inclusion of micro bubbles often exists in polyimide films (PI) during the liquid molding process, which can largely affect the mechanical performance. However, there lacks an effective method to quantify the bubble content. Herein, an obvious tension variation of a pre-stressed polyimide film i...
Guardado en:
Autores principales: | , , , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Elsevier
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/e304a858735042428f01a6b3e9c3237b |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:e304a858735042428f01a6b3e9c3237b |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:e304a858735042428f01a6b3e9c3237b2021-11-24T04:23:38ZExperimental methodology for bubble content measurement of thin films0142-941810.1016/j.polymertesting.2020.106876https://doaj.org/article/e304a858735042428f01a6b3e9c3237b2021-01-01T00:00:00Zhttp://www.sciencedirect.com/science/article/pii/S014294182032105Xhttps://doaj.org/toc/0142-9418The inclusion of micro bubbles often exists in polyimide films (PI) during the liquid molding process, which can largely affect the mechanical performance. However, there lacks an effective method to quantify the bubble content. Herein, an obvious tension variation of a pre-stressed polyimide film is observed firstly in a vacuum test. This phenomenon is assumed that, when the vacuum level of the testing environment increases, the inner bubbles would expand mainly out of plane, resulting in an in-plane contraction, and the tension varies accordingly. This tension variation ability is found quite stable despite of the stochastic micro-bubble distribution, which could be utilized to quantify the bubble content. Moreover, a film with meso-size bubbles is tested to have the similar tension variation ability. According to the experimental results, the tension variation ability can be basically stable when the bubbles in the length and width directions reach a certain number (e.g. 10).Yibei ZhangBing ZhaoJianhui HuWujun ChenXiaowei DengZhengyue YuChao XieFujun PengXiaofei HuangElsevierarticleBubble contentThin filmsTension variation testsVacuum testsMeso-size bubblesPolymers and polymer manufactureTP1080-1185ENPolymer Testing, Vol 93, Iss , Pp 106876- (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Bubble content Thin films Tension variation tests Vacuum tests Meso-size bubbles Polymers and polymer manufacture TP1080-1185 |
spellingShingle |
Bubble content Thin films Tension variation tests Vacuum tests Meso-size bubbles Polymers and polymer manufacture TP1080-1185 Yibei Zhang Bing Zhao Jianhui Hu Wujun Chen Xiaowei Deng Zhengyue Yu Chao Xie Fujun Peng Xiaofei Huang Experimental methodology for bubble content measurement of thin films |
description |
The inclusion of micro bubbles often exists in polyimide films (PI) during the liquid molding process, which can largely affect the mechanical performance. However, there lacks an effective method to quantify the bubble content. Herein, an obvious tension variation of a pre-stressed polyimide film is observed firstly in a vacuum test. This phenomenon is assumed that, when the vacuum level of the testing environment increases, the inner bubbles would expand mainly out of plane, resulting in an in-plane contraction, and the tension varies accordingly. This tension variation ability is found quite stable despite of the stochastic micro-bubble distribution, which could be utilized to quantify the bubble content. Moreover, a film with meso-size bubbles is tested to have the similar tension variation ability. According to the experimental results, the tension variation ability can be basically stable when the bubbles in the length and width directions reach a certain number (e.g. 10). |
format |
article |
author |
Yibei Zhang Bing Zhao Jianhui Hu Wujun Chen Xiaowei Deng Zhengyue Yu Chao Xie Fujun Peng Xiaofei Huang |
author_facet |
Yibei Zhang Bing Zhao Jianhui Hu Wujun Chen Xiaowei Deng Zhengyue Yu Chao Xie Fujun Peng Xiaofei Huang |
author_sort |
Yibei Zhang |
title |
Experimental methodology for bubble content measurement of thin films |
title_short |
Experimental methodology for bubble content measurement of thin films |
title_full |
Experimental methodology for bubble content measurement of thin films |
title_fullStr |
Experimental methodology for bubble content measurement of thin films |
title_full_unstemmed |
Experimental methodology for bubble content measurement of thin films |
title_sort |
experimental methodology for bubble content measurement of thin films |
publisher |
Elsevier |
publishDate |
2021 |
url |
https://doaj.org/article/e304a858735042428f01a6b3e9c3237b |
work_keys_str_mv |
AT yibeizhang experimentalmethodologyforbubblecontentmeasurementofthinfilms AT bingzhao experimentalmethodologyforbubblecontentmeasurementofthinfilms AT jianhuihu experimentalmethodologyforbubblecontentmeasurementofthinfilms AT wujunchen experimentalmethodologyforbubblecontentmeasurementofthinfilms AT xiaoweideng experimentalmethodologyforbubblecontentmeasurementofthinfilms AT zhengyueyu experimentalmethodologyforbubblecontentmeasurementofthinfilms AT chaoxie experimentalmethodologyforbubblecontentmeasurementofthinfilms AT fujunpeng experimentalmethodologyforbubblecontentmeasurementofthinfilms AT xiaofeihuang experimentalmethodologyforbubblecontentmeasurementofthinfilms |
_version_ |
1718416065965326336 |