The Impact of IOL Abbe Number on Polychromatic Image Quality of Pseudophakic Eyes

Arthur Bradley,1 Renfeng Xu,1,2 Huachun Wang,2 Matt Jaskulski,1 Xin Hong,3 Nicolette Brink,3 Stephen Van Noy3 1School of Optometry, Indiana University, Bloomington, IN 47405, USA; 2Department of Ophthalmology and Vision Science, University of Nebraska Medical Center, Omaha, NE 68198, USA; 3Alcon Res...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Bradley A, Xu R, Wang H, Jaskulski M, Hong X, Brink N, Van Noy S
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2020
Materias:
iol
Acceso en línea:https://doaj.org/article/e3e50025d0d14ba292597f50355f3852
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:e3e50025d0d14ba292597f50355f3852
record_format dspace
spelling oai:doaj.org-article:e3e50025d0d14ba292597f50355f38522021-12-02T10:08:47ZThe Impact of IOL Abbe Number on Polychromatic Image Quality of Pseudophakic Eyes1177-5483https://doaj.org/article/e3e50025d0d14ba292597f50355f38522020-08-01T00:00:00Zhttps://www.dovepress.com/the-impact-of-iol-abbe-number-on-polychromatic-image-quality-of-pseudo-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Arthur Bradley,1 Renfeng Xu,1,2 Huachun Wang,2 Matt Jaskulski,1 Xin Hong,3 Nicolette Brink,3 Stephen Van Noy3 1School of Optometry, Indiana University, Bloomington, IN 47405, USA; 2Department of Ophthalmology and Vision Science, University of Nebraska Medical Center, Omaha, NE 68198, USA; 3Alcon Research Laboratories, Fort Worth, TX 76134-2001, USACorrespondence: Arthur BradleyIndiana University, 800 E Atwater Ave, Bloomington, IN 47405, USATel +1 812-855-2465Fax +1 812-855-7045Email bradley@indiana.eduPurpose: The human eye exhibits large amounts (2.5 diopters) of longitudinal chromatic aberration (LCA). Its impact on polychromatic image quality, however, has been shown experimentally and by computer modeling to be small or absent. We hypothesized that modest changes in pseudophakic LCA created by higher and lower Abbe number materials will have little or no impact on polychromatic image quality in pseudophakic eyes.Materials and Methods: Using published chromatic and monochromatic aberration data from pseudophakic eyes and higher and lower Abbe number materials (37 and 55), we computed monochromatic point spread functions for 21 wavelengths across the visible spectrum. After weighting by either the RGB spectra of a liquid crystal display or by a flat white spectrum, they were weighted by the human spectral sensitivity function (Vλ) before being added to generate polychromatic PSFs.Results: In the absence of monochromatic aberrations, the reduced LCA due to higher Abbe number intraocular lens (IOL) materials resulted in a reduction of 0.08 diopters in the mean defocus generated by LCA. At the retinal plane, the higher Abbe number pseudophakic model produced improvements in polychromatic modulation transfer functions (MTFs) similar to those generated by a 0.05 diopter reduction in spherical defocus. When monochromatic aberrations were added to make the model more representative of actual pseudophakic eyes, the differences in image quality became sub-threshold for human vision or disappeared completely.Conclusion: The anticipated gains in polychromatic image quality from employing higher Abbe number IOL materials with reduced LCA do not materialize in plausible aberrated models of pseudophakic eyes.Keywords: Abbe number, chromatic aberrations, IOL, image qualityBradley AXu RWang HJaskulski MHong XBrink NVan Noy SDove Medical Pressarticleabbe numberchromatic aberrationsiolimage qualityOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 14, Pp 2271-2281 (2020)
institution DOAJ
collection DOAJ
language EN
topic abbe number
chromatic aberrations
iol
image quality
Ophthalmology
RE1-994
spellingShingle abbe number
chromatic aberrations
iol
image quality
Ophthalmology
RE1-994
Bradley A
Xu R
Wang H
Jaskulski M
Hong X
Brink N
Van Noy S
The Impact of IOL Abbe Number on Polychromatic Image Quality of Pseudophakic Eyes
description Arthur Bradley,1 Renfeng Xu,1,2 Huachun Wang,2 Matt Jaskulski,1 Xin Hong,3 Nicolette Brink,3 Stephen Van Noy3 1School of Optometry, Indiana University, Bloomington, IN 47405, USA; 2Department of Ophthalmology and Vision Science, University of Nebraska Medical Center, Omaha, NE 68198, USA; 3Alcon Research Laboratories, Fort Worth, TX 76134-2001, USACorrespondence: Arthur BradleyIndiana University, 800 E Atwater Ave, Bloomington, IN 47405, USATel +1 812-855-2465Fax +1 812-855-7045Email bradley@indiana.eduPurpose: The human eye exhibits large amounts (2.5 diopters) of longitudinal chromatic aberration (LCA). Its impact on polychromatic image quality, however, has been shown experimentally and by computer modeling to be small or absent. We hypothesized that modest changes in pseudophakic LCA created by higher and lower Abbe number materials will have little or no impact on polychromatic image quality in pseudophakic eyes.Materials and Methods: Using published chromatic and monochromatic aberration data from pseudophakic eyes and higher and lower Abbe number materials (37 and 55), we computed monochromatic point spread functions for 21 wavelengths across the visible spectrum. After weighting by either the RGB spectra of a liquid crystal display or by a flat white spectrum, they were weighted by the human spectral sensitivity function (Vλ) before being added to generate polychromatic PSFs.Results: In the absence of monochromatic aberrations, the reduced LCA due to higher Abbe number intraocular lens (IOL) materials resulted in a reduction of 0.08 diopters in the mean defocus generated by LCA. At the retinal plane, the higher Abbe number pseudophakic model produced improvements in polychromatic modulation transfer functions (MTFs) similar to those generated by a 0.05 diopter reduction in spherical defocus. When monochromatic aberrations were added to make the model more representative of actual pseudophakic eyes, the differences in image quality became sub-threshold for human vision or disappeared completely.Conclusion: The anticipated gains in polychromatic image quality from employing higher Abbe number IOL materials with reduced LCA do not materialize in plausible aberrated models of pseudophakic eyes.Keywords: Abbe number, chromatic aberrations, IOL, image quality
format article
author Bradley A
Xu R
Wang H
Jaskulski M
Hong X
Brink N
Van Noy S
author_facet Bradley A
Xu R
Wang H
Jaskulski M
Hong X
Brink N
Van Noy S
author_sort Bradley A
title The Impact of IOL Abbe Number on Polychromatic Image Quality of Pseudophakic Eyes
title_short The Impact of IOL Abbe Number on Polychromatic Image Quality of Pseudophakic Eyes
title_full The Impact of IOL Abbe Number on Polychromatic Image Quality of Pseudophakic Eyes
title_fullStr The Impact of IOL Abbe Number on Polychromatic Image Quality of Pseudophakic Eyes
title_full_unstemmed The Impact of IOL Abbe Number on Polychromatic Image Quality of Pseudophakic Eyes
title_sort impact of iol abbe number on polychromatic image quality of pseudophakic eyes
publisher Dove Medical Press
publishDate 2020
url https://doaj.org/article/e3e50025d0d14ba292597f50355f3852
work_keys_str_mv AT bradleya theimpactofiolabbenumberonpolychromaticimagequalityofpseudophakiceyes
AT xur theimpactofiolabbenumberonpolychromaticimagequalityofpseudophakiceyes
AT wangh theimpactofiolabbenumberonpolychromaticimagequalityofpseudophakiceyes
AT jaskulskim theimpactofiolabbenumberonpolychromaticimagequalityofpseudophakiceyes
AT hongx theimpactofiolabbenumberonpolychromaticimagequalityofpseudophakiceyes
AT brinkn theimpactofiolabbenumberonpolychromaticimagequalityofpseudophakiceyes
AT vannoys theimpactofiolabbenumberonpolychromaticimagequalityofpseudophakiceyes
AT bradleya impactofiolabbenumberonpolychromaticimagequalityofpseudophakiceyes
AT xur impactofiolabbenumberonpolychromaticimagequalityofpseudophakiceyes
AT wangh impactofiolabbenumberonpolychromaticimagequalityofpseudophakiceyes
AT jaskulskim impactofiolabbenumberonpolychromaticimagequalityofpseudophakiceyes
AT hongx impactofiolabbenumberonpolychromaticimagequalityofpseudophakiceyes
AT brinkn impactofiolabbenumberonpolychromaticimagequalityofpseudophakiceyes
AT vannoys impactofiolabbenumberonpolychromaticimagequalityofpseudophakiceyes
_version_ 1718397612333203456