Concurrent Validation and Reference Values of Gluteus Medius Clinical Test
# Context The hip abductor muscles, mainly the gluteus medius, are responsible for controlling hip adduction in a closed kinetic chain. Frontal plane knee alignment, assessed during functional activities such squatting, jumping and running, may overload joint structures, like the anterior cruciate...
Guardado en:
Autores principales: | , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
North American Sports Medicine Institute
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/e4cfbe10ecf6426f92259911244bb7a6 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:e4cfbe10ecf6426f92259911244bb7a6 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:e4cfbe10ecf6426f92259911244bb7a62021-12-02T17:11:13ZConcurrent Validation and Reference Values of Gluteus Medius Clinical Test10.26603/001c.214772159-2896https://doaj.org/article/e4cfbe10ecf6426f92259911244bb7a62021-04-01T00:00:00Zhttps://ijspt.scholasticahq.com/article/21477-concurrent-validation-and-reference-values-of-gluteus-medius-clinical-test.pdfhttps://doaj.org/toc/2159-2896# Context The hip abductor muscles, mainly the gluteus medius, are responsible for controlling hip adduction in a closed kinetic chain. Frontal plane knee alignment, assessed during functional activities such squatting, jumping and running, may overload joint structures, like the anterior cruciate ligament and patellofemoral joint. The hand-held dynamometer is reliable and effective for testing the muscular strength of the hip abductors. # Objectives (1) To assess the concurrent validity between the gluteus medius clinical test and a maximum isometric force test of the hip abductors using the hand-held dynamometer; (2) to determine the intra and inter-examiner reliability for the application of the gluteus medius clinical test; and (3) to describe reference values of gluteus medius clinical test on a population of youth athletes. # Design Cross-sectional. # Methods Thirty healthy individuals were recruited for validity and reliability testing. On the first day, participants performed the maximal isometric test of the hip abductors, measured via hand-held dynamometry. On the following week, the gluteus medius clinical test was performed. Intraclass correlation coefficients (ICC~2,2~) were computed for the reliability analysis, with a 95% confidence interval. To generate reference values, the gluteus medius clinical test was performed on 273 athletes. # Results The results of this study indicated a weak positive correlation (r = 0.436, p = 0.001) between tests, which indicates that they examine different domains of gluteus medius muscle function, likely endurance and muscle strength. The magnitude of computed ICCs (\>0.95) indicates excellent intra- and inter-examiner reliability. # Conclusion The findings of the current study indicate that the gluteus medius clinical test is reliable and examines a domain of muscular function not fully captured by HHD. The clinical test developed in this study is low-cost and can be included for gluteus medius assessment. # Level of evidence Level 3.Amanda S S TeixeiraPaula L SilvaSabrina P CintraFernanda ViegasLuciana D MendonçaNatália F N BittencourtNorth American Sports Medicine InstitutearticleSports medicineRC1200-1245ENInternational Journal of Sports Physical Therapy, Vol 16, Iss 2 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Sports medicine RC1200-1245 |
spellingShingle |
Sports medicine RC1200-1245 Amanda S S Teixeira Paula L Silva Sabrina P Cintra Fernanda Viegas Luciana D Mendonça Natália F N Bittencourt Concurrent Validation and Reference Values of Gluteus Medius Clinical Test |
description |
# Context
The hip abductor muscles, mainly the gluteus medius, are responsible for controlling hip adduction in a closed kinetic chain. Frontal plane knee alignment, assessed during functional activities such squatting, jumping and running, may overload joint structures, like the anterior cruciate ligament and patellofemoral joint. The hand-held dynamometer is reliable and effective for testing the muscular strength of the hip abductors.
# Objectives
(1) To assess the concurrent validity between the gluteus medius clinical test and a maximum isometric force test of the hip abductors using the hand-held dynamometer; (2) to determine the intra and inter-examiner reliability for the application of the gluteus medius clinical test; and (3) to describe reference values of gluteus medius clinical test on a population of youth athletes.
# Design
Cross-sectional.
# Methods
Thirty healthy individuals were recruited for validity and reliability testing. On the first day, participants performed the maximal isometric test of the hip abductors, measured via hand-held dynamometry. On the following week, the gluteus medius clinical test was performed. Intraclass correlation coefficients (ICC~2,2~) were computed for the reliability analysis, with a 95% confidence interval. To generate reference values, the gluteus medius clinical test was performed on 273 athletes.
# Results
The results of this study indicated a weak positive correlation (r = 0.436, p = 0.001) between tests, which indicates that they examine different domains of gluteus medius muscle function, likely endurance and muscle strength. The magnitude of computed ICCs (\>0.95) indicates excellent intra- and inter-examiner reliability.
# Conclusion
The findings of the current study indicate that the gluteus medius clinical test is reliable and examines a domain of muscular function not fully captured by HHD. The clinical test developed in this study is low-cost and can be included for gluteus medius assessment.
# Level of evidence
Level 3. |
format |
article |
author |
Amanda S S Teixeira Paula L Silva Sabrina P Cintra Fernanda Viegas Luciana D Mendonça Natália F N Bittencourt |
author_facet |
Amanda S S Teixeira Paula L Silva Sabrina P Cintra Fernanda Viegas Luciana D Mendonça Natália F N Bittencourt |
author_sort |
Amanda S S Teixeira |
title |
Concurrent Validation and Reference Values of Gluteus Medius Clinical Test |
title_short |
Concurrent Validation and Reference Values of Gluteus Medius Clinical Test |
title_full |
Concurrent Validation and Reference Values of Gluteus Medius Clinical Test |
title_fullStr |
Concurrent Validation and Reference Values of Gluteus Medius Clinical Test |
title_full_unstemmed |
Concurrent Validation and Reference Values of Gluteus Medius Clinical Test |
title_sort |
concurrent validation and reference values of gluteus medius clinical test |
publisher |
North American Sports Medicine Institute |
publishDate |
2021 |
url |
https://doaj.org/article/e4cfbe10ecf6426f92259911244bb7a6 |
work_keys_str_mv |
AT amandassteixeira concurrentvalidationandreferencevaluesofgluteusmediusclinicaltest AT paulalsilva concurrentvalidationandreferencevaluesofgluteusmediusclinicaltest AT sabrinapcintra concurrentvalidationandreferencevaluesofgluteusmediusclinicaltest AT fernandaviegas concurrentvalidationandreferencevaluesofgluteusmediusclinicaltest AT lucianadmendonca concurrentvalidationandreferencevaluesofgluteusmediusclinicaltest AT nataliafnbittencourt concurrentvalidationandreferencevaluesofgluteusmediusclinicaltest |
_version_ |
1718381529926729728 |