Under-flap stromal bed CXL for early post-LASIK ectasia: a novel treatment technique

Avi Wallerstein,1,2 Eser Adiguzel,2 Mathieu Gauvin,1,2 Nima Mohammad-Shahi,1 Mark Cohen2,3 1Department of Ophthalmology, Faculty of Medicine, McGill University, 2LASIK MD, Montreal, 3Department of Surgery, Faculty of Medicine and Health Sciences, University of Sherbrooke, Sherbrooke, QC, Canada Pu...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Wallerstein A, Adiguzel E, Gauvin M, Mohammad-Shahi N, Cohen M
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2016
Materias:
CXL
Acceso en línea:https://doaj.org/article/e4d697111b784b8d83e6a6d2670a9a75
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:e4d697111b784b8d83e6a6d2670a9a75
record_format dspace
spelling oai:doaj.org-article:e4d697111b784b8d83e6a6d2670a9a752021-12-02T00:21:39ZUnder-flap stromal bed CXL for early post-LASIK ectasia: a novel treatment technique1177-5483https://doaj.org/article/e4d697111b784b8d83e6a6d2670a9a752016-12-01T00:00:00Zhttps://www.dovepress.com/under-flap-stromal-bed-cxl-for-early-post-lasik-ectasia-a-novel-treatm-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Avi Wallerstein,1,2 Eser Adiguzel,2 Mathieu Gauvin,1,2 Nima Mohammad-Shahi,1 Mark Cohen2,3 1Department of Ophthalmology, Faculty of Medicine, McGill University, 2LASIK MD, Montreal, 3Department of Surgery, Faculty of Medicine and Health Sciences, University of Sherbrooke, Sherbrooke, QC, Canada Purpose: Collagen cross-linking (CXL) for post-laser-assisted in situ keratomileusis (LASIK) ectasia (PLE) is traditionally performed either epi-on or epi-off on the corneal surface. This study describes a novel technique in treating early PLE with under-flap CXL (ufCXL) to the stromal bed and reports on 6-month outcomes.Patients and methods: Case series of seven patients (eight eyes) with topography-diagnosed early PLE treated with ufCXL. Inclusion criteria were early, mild PLE defined as new-onset postoperative manifest refraction cylinder ≤1.50 D, with new topographic inferior steepening consistent with ectasia, uncorrected distance visual acuity (UDVA) of 20/40 or better, and corrected distance visual acuity (CDVA) of 20/25 or better. Existing LASIK flap was lifted, riboflavin was applied directly to the stromal bed, flap was repositioned, and 18 mW/cm2 ultraviolet light was applied for 3 minutes to the corneal surface. Post-ufCXL manifest refraction, UDVA and CDVA, corneal cylinder, Kmax, and corneal irregularity index were compared with pre-ufCXL measurements.Results: Patients had a pre-ufCXL sphere of 0.09±0.48 D and cylinder of −0.78±0.49 D. At 6 months, post-ufCXL sphere (0.06±0.8 D; P=0.89) and cylinder (−1.09±0.76 D, P=0.26) were unchanged. Cumulative post-ufCXL UDVA was unchanged, achieving 20/20, 20/30, and 20/40 in 25%, 88%, and 88%, respectively, compared with 13%, 63%, and 88% pre-ufCXL (P=0.68). Post-ufCXL CDVA was unchanged (P=0.93) with a gain of one line in two eyes, a loss of one line in one eye, and five eyes unchanged. The efficacy index (P=0.76), safety index (P=0.89), Kmax (P=0.94), and corneal irregularity index (P=0.73) were also unchanged.Conclusion: Preliminary results with ufCXL for early PLE are promising, demonstrating maintenance of visual accuracy, efficacy, safety, Kmax, and cylinder, with much quicker recovery times than surface CXL. Keywords: CXL, LASIK, ufCXL, post-LASIK ectasia, cross-linking, LASIK complications, stromal bedWallerstein AAdiguzel EGauvin MMohammad-Shahi NCohen MDove Medical PressarticleCXLLASIKufCXLPost-LASIK EctasiaOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 11, Pp 1-8 (2016)
institution DOAJ
collection DOAJ
language EN
topic CXL
LASIK
ufCXL
Post-LASIK Ectasia
Ophthalmology
RE1-994
spellingShingle CXL
LASIK
ufCXL
Post-LASIK Ectasia
Ophthalmology
RE1-994
Wallerstein A
Adiguzel E
Gauvin M
Mohammad-Shahi N
Cohen M
Under-flap stromal bed CXL for early post-LASIK ectasia: a novel treatment technique
description Avi Wallerstein,1,2 Eser Adiguzel,2 Mathieu Gauvin,1,2 Nima Mohammad-Shahi,1 Mark Cohen2,3 1Department of Ophthalmology, Faculty of Medicine, McGill University, 2LASIK MD, Montreal, 3Department of Surgery, Faculty of Medicine and Health Sciences, University of Sherbrooke, Sherbrooke, QC, Canada Purpose: Collagen cross-linking (CXL) for post-laser-assisted in situ keratomileusis (LASIK) ectasia (PLE) is traditionally performed either epi-on or epi-off on the corneal surface. This study describes a novel technique in treating early PLE with under-flap CXL (ufCXL) to the stromal bed and reports on 6-month outcomes.Patients and methods: Case series of seven patients (eight eyes) with topography-diagnosed early PLE treated with ufCXL. Inclusion criteria were early, mild PLE defined as new-onset postoperative manifest refraction cylinder ≤1.50 D, with new topographic inferior steepening consistent with ectasia, uncorrected distance visual acuity (UDVA) of 20/40 or better, and corrected distance visual acuity (CDVA) of 20/25 or better. Existing LASIK flap was lifted, riboflavin was applied directly to the stromal bed, flap was repositioned, and 18 mW/cm2 ultraviolet light was applied for 3 minutes to the corneal surface. Post-ufCXL manifest refraction, UDVA and CDVA, corneal cylinder, Kmax, and corneal irregularity index were compared with pre-ufCXL measurements.Results: Patients had a pre-ufCXL sphere of 0.09±0.48 D and cylinder of −0.78±0.49 D. At 6 months, post-ufCXL sphere (0.06±0.8 D; P=0.89) and cylinder (−1.09±0.76 D, P=0.26) were unchanged. Cumulative post-ufCXL UDVA was unchanged, achieving 20/20, 20/30, and 20/40 in 25%, 88%, and 88%, respectively, compared with 13%, 63%, and 88% pre-ufCXL (P=0.68). Post-ufCXL CDVA was unchanged (P=0.93) with a gain of one line in two eyes, a loss of one line in one eye, and five eyes unchanged. The efficacy index (P=0.76), safety index (P=0.89), Kmax (P=0.94), and corneal irregularity index (P=0.73) were also unchanged.Conclusion: Preliminary results with ufCXL for early PLE are promising, demonstrating maintenance of visual accuracy, efficacy, safety, Kmax, and cylinder, with much quicker recovery times than surface CXL. Keywords: CXL, LASIK, ufCXL, post-LASIK ectasia, cross-linking, LASIK complications, stromal bed
format article
author Wallerstein A
Adiguzel E
Gauvin M
Mohammad-Shahi N
Cohen M
author_facet Wallerstein A
Adiguzel E
Gauvin M
Mohammad-Shahi N
Cohen M
author_sort Wallerstein A
title Under-flap stromal bed CXL for early post-LASIK ectasia: a novel treatment technique
title_short Under-flap stromal bed CXL for early post-LASIK ectasia: a novel treatment technique
title_full Under-flap stromal bed CXL for early post-LASIK ectasia: a novel treatment technique
title_fullStr Under-flap stromal bed CXL for early post-LASIK ectasia: a novel treatment technique
title_full_unstemmed Under-flap stromal bed CXL for early post-LASIK ectasia: a novel treatment technique
title_sort under-flap stromal bed cxl for early post-lasik ectasia: a novel treatment technique
publisher Dove Medical Press
publishDate 2016
url https://doaj.org/article/e4d697111b784b8d83e6a6d2670a9a75
work_keys_str_mv AT wallersteina underflapstromalbedcxlforearlypostlasikectasiaanoveltreatmenttechnique
AT adiguzele underflapstromalbedcxlforearlypostlasikectasiaanoveltreatmenttechnique
AT gauvinm underflapstromalbedcxlforearlypostlasikectasiaanoveltreatmenttechnique
AT mohammadshahin underflapstromalbedcxlforearlypostlasikectasiaanoveltreatmenttechnique
AT cohenm underflapstromalbedcxlforearlypostlasikectasiaanoveltreatmenttechnique
_version_ 1718403837840064512