A review on imaging techniques and quantitative measurements for dynamic imaging of cerebral aneurysm pulsations

Abstract Measurement of intracranial aneurysm wall motion may refine the current rupture risk estimation. A golden standard for measuring aneurysm pulsation is lacking. The aim is to evaluate magnitudes of aneurysm pulsation as published in current literature. Embase and PubMed were searched for pub...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: L. B. Stam, R. Aquarius, G. A. de Jong, C. H. Slump, F. J. A. Meijer, H. D. Boogaarts
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/e4f32be9d9e4499b80f733fe84493047
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:e4f32be9d9e4499b80f733fe84493047
record_format dspace
spelling oai:doaj.org-article:e4f32be9d9e4499b80f733fe844930472021-12-02T14:16:07ZA review on imaging techniques and quantitative measurements for dynamic imaging of cerebral aneurysm pulsations10.1038/s41598-021-81753-z2045-2322https://doaj.org/article/e4f32be9d9e4499b80f733fe844930472021-01-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-81753-zhttps://doaj.org/toc/2045-2322Abstract Measurement of intracranial aneurysm wall motion may refine the current rupture risk estimation. A golden standard for measuring aneurysm pulsation is lacking. The aim is to evaluate magnitudes of aneurysm pulsation as published in current literature. Embase and PubMed were searched for publications containing quantitative measures of cardiac-cycle related cerebral aneurysm pulsation (no date or language restrictions). Eleven studies were included, covering 197 unruptured and untreated cerebral aneurysms. Quantitative pulsation measurements were extracted from the studies. Characteristics of the study population and aneurysms were taken into account, as well as the imaging modality, scanning technique and data processing methods used. A meta-analysis was performed of studies with similar methodologies and individual IA measures and locations. The magnitude of the absolute volume pulsations varied between 14 ± 9 mm3 and 106 ± 123 mm3 and the mean relative volume change varied between 5 and 36%. The meta-analysis revealed a positive correlation between size and absolute volume change. The relative volume change in Basilar artery aneurysms seems smaller. No authors were contacted for original study data and articles only describing visual pulsations were excluded. The variation in methodologies impedes an accurate estimation of the magnitude of IA pulsations. Validation of aneurysm pulsation measurement is crucial prior to clinical studies evaluating IA pulsatility in relation to IA rupture risk. Prerequisite is a reliable and robust imaging method with high spatial and temporal resolution and standardization of the image analysis methods.L. B. StamR. AquariusG. A. de JongC. H. SlumpF. J. A. MeijerH. D. BoogaartsNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-9 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
L. B. Stam
R. Aquarius
G. A. de Jong
C. H. Slump
F. J. A. Meijer
H. D. Boogaarts
A review on imaging techniques and quantitative measurements for dynamic imaging of cerebral aneurysm pulsations
description Abstract Measurement of intracranial aneurysm wall motion may refine the current rupture risk estimation. A golden standard for measuring aneurysm pulsation is lacking. The aim is to evaluate magnitudes of aneurysm pulsation as published in current literature. Embase and PubMed were searched for publications containing quantitative measures of cardiac-cycle related cerebral aneurysm pulsation (no date or language restrictions). Eleven studies were included, covering 197 unruptured and untreated cerebral aneurysms. Quantitative pulsation measurements were extracted from the studies. Characteristics of the study population and aneurysms were taken into account, as well as the imaging modality, scanning technique and data processing methods used. A meta-analysis was performed of studies with similar methodologies and individual IA measures and locations. The magnitude of the absolute volume pulsations varied between 14 ± 9 mm3 and 106 ± 123 mm3 and the mean relative volume change varied between 5 and 36%. The meta-analysis revealed a positive correlation between size and absolute volume change. The relative volume change in Basilar artery aneurysms seems smaller. No authors were contacted for original study data and articles only describing visual pulsations were excluded. The variation in methodologies impedes an accurate estimation of the magnitude of IA pulsations. Validation of aneurysm pulsation measurement is crucial prior to clinical studies evaluating IA pulsatility in relation to IA rupture risk. Prerequisite is a reliable and robust imaging method with high spatial and temporal resolution and standardization of the image analysis methods.
format article
author L. B. Stam
R. Aquarius
G. A. de Jong
C. H. Slump
F. J. A. Meijer
H. D. Boogaarts
author_facet L. B. Stam
R. Aquarius
G. A. de Jong
C. H. Slump
F. J. A. Meijer
H. D. Boogaarts
author_sort L. B. Stam
title A review on imaging techniques and quantitative measurements for dynamic imaging of cerebral aneurysm pulsations
title_short A review on imaging techniques and quantitative measurements for dynamic imaging of cerebral aneurysm pulsations
title_full A review on imaging techniques and quantitative measurements for dynamic imaging of cerebral aneurysm pulsations
title_fullStr A review on imaging techniques and quantitative measurements for dynamic imaging of cerebral aneurysm pulsations
title_full_unstemmed A review on imaging techniques and quantitative measurements for dynamic imaging of cerebral aneurysm pulsations
title_sort review on imaging techniques and quantitative measurements for dynamic imaging of cerebral aneurysm pulsations
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/e4f32be9d9e4499b80f733fe84493047
work_keys_str_mv AT lbstam areviewonimagingtechniquesandquantitativemeasurementsfordynamicimagingofcerebralaneurysmpulsations
AT raquarius areviewonimagingtechniquesandquantitativemeasurementsfordynamicimagingofcerebralaneurysmpulsations
AT gadejong areviewonimagingtechniquesandquantitativemeasurementsfordynamicimagingofcerebralaneurysmpulsations
AT chslump areviewonimagingtechniquesandquantitativemeasurementsfordynamicimagingofcerebralaneurysmpulsations
AT fjameijer areviewonimagingtechniquesandquantitativemeasurementsfordynamicimagingofcerebralaneurysmpulsations
AT hdboogaarts areviewonimagingtechniquesandquantitativemeasurementsfordynamicimagingofcerebralaneurysmpulsations
AT lbstam reviewonimagingtechniquesandquantitativemeasurementsfordynamicimagingofcerebralaneurysmpulsations
AT raquarius reviewonimagingtechniquesandquantitativemeasurementsfordynamicimagingofcerebralaneurysmpulsations
AT gadejong reviewonimagingtechniquesandquantitativemeasurementsfordynamicimagingofcerebralaneurysmpulsations
AT chslump reviewonimagingtechniquesandquantitativemeasurementsfordynamicimagingofcerebralaneurysmpulsations
AT fjameijer reviewonimagingtechniquesandquantitativemeasurementsfordynamicimagingofcerebralaneurysmpulsations
AT hdboogaarts reviewonimagingtechniquesandquantitativemeasurementsfordynamicimagingofcerebralaneurysmpulsations
_version_ 1718391756043583488