Accuracy of axial length measurements obtained by optical biometry and acoustic biometry in rhegmatogenous retinal detachment: a prospective study
Pear Pongsachareonnont, Sagol Tangjanyatam Vitreoretinal Research Unit, Department of Ophthalmology, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Bangkok, Thailand Purpose: We compared the accuracy of axial length (AL) measurement...
Guardado en:
Autores principales: | , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2018
|
Materias: | |
Acceso en línea: | https://doaj.org/article/e5fd94efba234e89b711189745f20444 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:e5fd94efba234e89b711189745f20444 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:e5fd94efba234e89b711189745f204442021-12-02T06:39:39ZAccuracy of axial length measurements obtained by optical biometry and acoustic biometry in rhegmatogenous retinal detachment: a prospective study1177-5483https://doaj.org/article/e5fd94efba234e89b711189745f204442018-05-01T00:00:00Zhttps://www.dovepress.com/accuracy-of-axial-length-measurements-obtained-by-optical-biometry-and-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Pear Pongsachareonnont, Sagol Tangjanyatam Vitreoretinal Research Unit, Department of Ophthalmology, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Bangkok, Thailand Purpose: We compared the accuracy of axial length (AL) measurement obtained by optical biometry with that obtained by acoustic biometry in eyes with rhegmatogenous retinal detachment (RRD). Patients and methods: This prospective descriptive analytic study measured the AL of eyes with RRD preoperatively and 3 months postoperatively using optical biometry (intraocular lens [IOL] master group) and acoustic biometry (immersion A-scan group). Preoperative and postoperative measurements were compared by paired t-test. The agreement between preoperative and postoperative measurements was analyzed using a Bland–Altman plot. Subgroup analysis of macular involvement status was performed. Results: Twenty-seven eyes were analyzed in this study. The mean AL in the IOL master group was 23.58±0.97 mm preoperatively and 24.17±1.16 mm postoperatively; the mean difference was −0.59±0.90 mm (P = 0.007). The mean AL in the immersion A-scan group was 24.29±1.59 mm preoperatively and 24.27±1.69 mm postoperatively; the mean difference was 0.02±0.48 mm (P = 0.827). Bland–Altman analysis revealed disagreement between preoperative and postoperative AL measurements in both techniques. In subgroup analysis of macula with RRD, there were significant differences between preoperative and postoperative AL measurements in the IOL master group (P = 0.014). Conclusion: Significant underestimation of AL measurement was observed when using the IOL master in eyes with RRD with macular involvement, which could affect IOL power selection. Keywords: IOL biometry, phacoemulsification, phacovitrectomy, cataract surgery biometryPongsachareonnont PTangjanyatam SDove Medical PressarticleIOL biometryphacoemulsificationphacovitrectomycataract surgery biometryOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 12, Pp 973-980 (2018) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
IOL biometry phacoemulsification phacovitrectomy cataract surgery biometry Ophthalmology RE1-994 |
spellingShingle |
IOL biometry phacoemulsification phacovitrectomy cataract surgery biometry Ophthalmology RE1-994 Pongsachareonnont P Tangjanyatam S Accuracy of axial length measurements obtained by optical biometry and acoustic biometry in rhegmatogenous retinal detachment: a prospective study |
description |
Pear Pongsachareonnont, Sagol Tangjanyatam Vitreoretinal Research Unit, Department of Ophthalmology, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Bangkok, Thailand Purpose: We compared the accuracy of axial length (AL) measurement obtained by optical biometry with that obtained by acoustic biometry in eyes with rhegmatogenous retinal detachment (RRD). Patients and methods: This prospective descriptive analytic study measured the AL of eyes with RRD preoperatively and 3 months postoperatively using optical biometry (intraocular lens [IOL] master group) and acoustic biometry (immersion A-scan group). Preoperative and postoperative measurements were compared by paired t-test. The agreement between preoperative and postoperative measurements was analyzed using a Bland–Altman plot. Subgroup analysis of macular involvement status was performed. Results: Twenty-seven eyes were analyzed in this study. The mean AL in the IOL master group was 23.58±0.97 mm preoperatively and 24.17±1.16 mm postoperatively; the mean difference was −0.59±0.90 mm (P = 0.007). The mean AL in the immersion A-scan group was 24.29±1.59 mm preoperatively and 24.27±1.69 mm postoperatively; the mean difference was 0.02±0.48 mm (P = 0.827). Bland–Altman analysis revealed disagreement between preoperative and postoperative AL measurements in both techniques. In subgroup analysis of macula with RRD, there were significant differences between preoperative and postoperative AL measurements in the IOL master group (P = 0.014). Conclusion: Significant underestimation of AL measurement was observed when using the IOL master in eyes with RRD with macular involvement, which could affect IOL power selection. Keywords: IOL biometry, phacoemulsification, phacovitrectomy, cataract surgery biometry |
format |
article |
author |
Pongsachareonnont P Tangjanyatam S |
author_facet |
Pongsachareonnont P Tangjanyatam S |
author_sort |
Pongsachareonnont P |
title |
Accuracy of axial length measurements obtained by optical biometry and acoustic biometry in rhegmatogenous retinal detachment: a prospective study |
title_short |
Accuracy of axial length measurements obtained by optical biometry and acoustic biometry in rhegmatogenous retinal detachment: a prospective study |
title_full |
Accuracy of axial length measurements obtained by optical biometry and acoustic biometry in rhegmatogenous retinal detachment: a prospective study |
title_fullStr |
Accuracy of axial length measurements obtained by optical biometry and acoustic biometry in rhegmatogenous retinal detachment: a prospective study |
title_full_unstemmed |
Accuracy of axial length measurements obtained by optical biometry and acoustic biometry in rhegmatogenous retinal detachment: a prospective study |
title_sort |
accuracy of axial length measurements obtained by optical biometry and acoustic biometry in rhegmatogenous retinal detachment: a prospective study |
publisher |
Dove Medical Press |
publishDate |
2018 |
url |
https://doaj.org/article/e5fd94efba234e89b711189745f20444 |
work_keys_str_mv |
AT pongsachareonnontp accuracyofaxiallengthmeasurementsobtainedbyopticalbiometryandacousticbiometryinrhegmatogenousretinaldetachmentaprospectivestudy AT tangjanyatams accuracyofaxiallengthmeasurementsobtainedbyopticalbiometryandacousticbiometryinrhegmatogenousretinaldetachmentaprospectivestudy |
_version_ |
1718399844191567872 |