Operation Strategy of Central Air Conditioning Virtual Power Plant Based on Risk Measurement Method
Virtual power plant is an integrated technology and operation mode to realize air-conditioning load participating in power system operation, further benefitting low carbon renewable energy applications. However, the principle of multi-system coupling in central air-conditioning poses a challenge to...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/e64f2ef262254506b1d7a1c1eafa4e96 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:e64f2ef262254506b1d7a1c1eafa4e96 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:e64f2ef262254506b1d7a1c1eafa4e962021-12-01T05:10:00ZOperation Strategy of Central Air Conditioning Virtual Power Plant Based on Risk Measurement Method2296-598X10.3389/fenrg.2021.773149https://doaj.org/article/e64f2ef262254506b1d7a1c1eafa4e962021-11-01T00:00:00Zhttps://www.frontiersin.org/articles/10.3389/fenrg.2021.773149/fullhttps://doaj.org/toc/2296-598XVirtual power plant is an integrated technology and operation mode to realize air-conditioning load participating in power system operation, further benefitting low carbon renewable energy applications. However, the principle of multi-system coupling in central air-conditioning poses a challenge to normal load regulation. Besides, the uncertainties of demand-side resources bring risks to the operation of virtual power plant. In this paper, the regulation characteristics of central air conditioning are obtained by experiment, while the potential of central air conditioning is quantified by a thermodynamic model, further resulting in the central air conditioning could be transformed into a virtual unit model. Then the dynamic capacity optimization strategy is formulated based on the risk measurement theory, while the generation task decomposition strategy is also formulated based on the equal increase rate criterion, thus forming a two-tier operation strategy of virtual power plant. Finally, illustrative case study is constructed to quantitatively analyze the power generation capacity and effectiveness of the virtual power plant. The effectiveness and practicability of the proposed strategy is also verified to benefit low carbon energy applications.Mingxing GuoXuxin GuoJianlin YangCiwei GaoTao ChenFrontiers Media S.A.articlecentral air conditioningvirtual power plantdynamic capacitydemand side managementrisk managemenentGeneral WorksAENFrontiers in Energy Research, Vol 9 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
central air conditioning virtual power plant dynamic capacity demand side management risk managemenent General Works A |
spellingShingle |
central air conditioning virtual power plant dynamic capacity demand side management risk managemenent General Works A Mingxing Guo Xuxin Guo Jianlin Yang Ciwei Gao Tao Chen Operation Strategy of Central Air Conditioning Virtual Power Plant Based on Risk Measurement Method |
description |
Virtual power plant is an integrated technology and operation mode to realize air-conditioning load participating in power system operation, further benefitting low carbon renewable energy applications. However, the principle of multi-system coupling in central air-conditioning poses a challenge to normal load regulation. Besides, the uncertainties of demand-side resources bring risks to the operation of virtual power plant. In this paper, the regulation characteristics of central air conditioning are obtained by experiment, while the potential of central air conditioning is quantified by a thermodynamic model, further resulting in the central air conditioning could be transformed into a virtual unit model. Then the dynamic capacity optimization strategy is formulated based on the risk measurement theory, while the generation task decomposition strategy is also formulated based on the equal increase rate criterion, thus forming a two-tier operation strategy of virtual power plant. Finally, illustrative case study is constructed to quantitatively analyze the power generation capacity and effectiveness of the virtual power plant. The effectiveness and practicability of the proposed strategy is also verified to benefit low carbon energy applications. |
format |
article |
author |
Mingxing Guo Xuxin Guo Jianlin Yang Ciwei Gao Tao Chen |
author_facet |
Mingxing Guo Xuxin Guo Jianlin Yang Ciwei Gao Tao Chen |
author_sort |
Mingxing Guo |
title |
Operation Strategy of Central Air Conditioning Virtual Power Plant Based on Risk Measurement Method |
title_short |
Operation Strategy of Central Air Conditioning Virtual Power Plant Based on Risk Measurement Method |
title_full |
Operation Strategy of Central Air Conditioning Virtual Power Plant Based on Risk Measurement Method |
title_fullStr |
Operation Strategy of Central Air Conditioning Virtual Power Plant Based on Risk Measurement Method |
title_full_unstemmed |
Operation Strategy of Central Air Conditioning Virtual Power Plant Based on Risk Measurement Method |
title_sort |
operation strategy of central air conditioning virtual power plant based on risk measurement method |
publisher |
Frontiers Media S.A. |
publishDate |
2021 |
url |
https://doaj.org/article/e64f2ef262254506b1d7a1c1eafa4e96 |
work_keys_str_mv |
AT mingxingguo operationstrategyofcentralairconditioningvirtualpowerplantbasedonriskmeasurementmethod AT xuxinguo operationstrategyofcentralairconditioningvirtualpowerplantbasedonriskmeasurementmethod AT jianlinyang operationstrategyofcentralairconditioningvirtualpowerplantbasedonriskmeasurementmethod AT ciweigao operationstrategyofcentralairconditioningvirtualpowerplantbasedonriskmeasurementmethod AT taochen operationstrategyofcentralairconditioningvirtualpowerplantbasedonriskmeasurementmethod |
_version_ |
1718405574492684288 |