Imprinted Zeolite Modified Carbon Paste Electrode as a Selective Sensor for Blood Glucose Analysis by Potentiometry

Imprinted zeolite modified carbon paste (carbon paste-IZ) electrode had been developed as a sensor to analyze blood glucose content by potentiometry. The used zeolite was Lynde Type A (LTA) that synthesized with a mole ratio of Na2O, Al2O3, SiO2 and H2O of 4:1:1.8:270, respectively while non-imprint...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Miratul Khasanah, Alfa Akustia Widati, Usreg Sri Handajani, Muji Harsini, Bahrotul Ilmiah, Irene Dinda Oktavia
Formato: article
Lenguaje:EN
Publicado: Department of Chemistry, Universitas Gadjah Mada 2020
Materias:
Acceso en línea:https://doaj.org/article/e6e2231c1d6141a1949ef88145d893c5
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:e6e2231c1d6141a1949ef88145d893c5
record_format dspace
spelling oai:doaj.org-article:e6e2231c1d6141a1949ef88145d893c52021-12-02T12:03:36ZImprinted Zeolite Modified Carbon Paste Electrode as a Selective Sensor for Blood Glucose Analysis by Potentiometry1411-94202460-157810.22146/ijc.49820https://doaj.org/article/e6e2231c1d6141a1949ef88145d893c52020-06-01T00:00:00Zhttps://jurnal.ugm.ac.id/ijc/article/view/49820https://doaj.org/toc/1411-9420https://doaj.org/toc/2460-1578Imprinted zeolite modified carbon paste (carbon paste-IZ) electrode had been developed as a sensor to analyze blood glucose content by potentiometry. The used zeolite was Lynde Type A (LTA) that synthesized with a mole ratio of Na2O, Al2O3, SiO2 and H2O of 4:1:1.8:270, respectively while non-imprinted zeolite was prepared with a mole ratio of glucose/Si of 0.0306. Glucose was then extracted from the zeolite framework using hot water (80 °C) to produce imprinted zeolite (IZ). The carbon paste-IZ electrode prepared from activated carbon, paraffin pastilles, and IZ with a mass ratio of 5:4:1 showed the best performance. The modified electrode demonstrated the measurement range of 10–4-10–2 M, the Nernst factor of 29.55 mV/decade, the response time less than 120 s, and the detection limit of 5.62 × 10–5 M. Ascorbic acid, uric acid, urea and creatinine did not interfere on the glucose analysis by potentiometry. Comparison test with spectrophotometry showed an accuracy of (90.7 ± 1.4)% (n = 5), while the application of the electrode to analyze five spiked serum samples showed recovery of (92.2 ± 1.3)% (n = 5). The electrode was stable for up to 9 weeks (168 times usage). Based on its performance, the developed electrode can be applied to analyze glucose in human serum sample and recommended for used in the medical field.Miratul KhasanahAlfa Akustia WidatiUsreg Sri HandajaniMuji HarsiniBahrotul IlmiahIrene Dinda OktaviaDepartment of Chemistry, Universitas Gadjah Madaarticleblood glucosecarbon paste electrodeimprinted zeolitepotentiometric sensorChemistryQD1-999ENIndonesian Journal of Chemistry, Vol 20, Iss 6, Pp 1301-1310 (2020)
institution DOAJ
collection DOAJ
language EN
topic blood glucose
carbon paste electrode
imprinted zeolite
potentiometric sensor
Chemistry
QD1-999
spellingShingle blood glucose
carbon paste electrode
imprinted zeolite
potentiometric sensor
Chemistry
QD1-999
Miratul Khasanah
Alfa Akustia Widati
Usreg Sri Handajani
Muji Harsini
Bahrotul Ilmiah
Irene Dinda Oktavia
Imprinted Zeolite Modified Carbon Paste Electrode as a Selective Sensor for Blood Glucose Analysis by Potentiometry
description Imprinted zeolite modified carbon paste (carbon paste-IZ) electrode had been developed as a sensor to analyze blood glucose content by potentiometry. The used zeolite was Lynde Type A (LTA) that synthesized with a mole ratio of Na2O, Al2O3, SiO2 and H2O of 4:1:1.8:270, respectively while non-imprinted zeolite was prepared with a mole ratio of glucose/Si of 0.0306. Glucose was then extracted from the zeolite framework using hot water (80 °C) to produce imprinted zeolite (IZ). The carbon paste-IZ electrode prepared from activated carbon, paraffin pastilles, and IZ with a mass ratio of 5:4:1 showed the best performance. The modified electrode demonstrated the measurement range of 10–4-10–2 M, the Nernst factor of 29.55 mV/decade, the response time less than 120 s, and the detection limit of 5.62 × 10–5 M. Ascorbic acid, uric acid, urea and creatinine did not interfere on the glucose analysis by potentiometry. Comparison test with spectrophotometry showed an accuracy of (90.7 ± 1.4)% (n = 5), while the application of the electrode to analyze five spiked serum samples showed recovery of (92.2 ± 1.3)% (n = 5). The electrode was stable for up to 9 weeks (168 times usage). Based on its performance, the developed electrode can be applied to analyze glucose in human serum sample and recommended for used in the medical field.
format article
author Miratul Khasanah
Alfa Akustia Widati
Usreg Sri Handajani
Muji Harsini
Bahrotul Ilmiah
Irene Dinda Oktavia
author_facet Miratul Khasanah
Alfa Akustia Widati
Usreg Sri Handajani
Muji Harsini
Bahrotul Ilmiah
Irene Dinda Oktavia
author_sort Miratul Khasanah
title Imprinted Zeolite Modified Carbon Paste Electrode as a Selective Sensor for Blood Glucose Analysis by Potentiometry
title_short Imprinted Zeolite Modified Carbon Paste Electrode as a Selective Sensor for Blood Glucose Analysis by Potentiometry
title_full Imprinted Zeolite Modified Carbon Paste Electrode as a Selective Sensor for Blood Glucose Analysis by Potentiometry
title_fullStr Imprinted Zeolite Modified Carbon Paste Electrode as a Selective Sensor for Blood Glucose Analysis by Potentiometry
title_full_unstemmed Imprinted Zeolite Modified Carbon Paste Electrode as a Selective Sensor for Blood Glucose Analysis by Potentiometry
title_sort imprinted zeolite modified carbon paste electrode as a selective sensor for blood glucose analysis by potentiometry
publisher Department of Chemistry, Universitas Gadjah Mada
publishDate 2020
url https://doaj.org/article/e6e2231c1d6141a1949ef88145d893c5
work_keys_str_mv AT miratulkhasanah imprintedzeolitemodifiedcarbonpasteelectrodeasaselectivesensorforbloodglucoseanalysisbypotentiometry
AT alfaakustiawidati imprintedzeolitemodifiedcarbonpasteelectrodeasaselectivesensorforbloodglucoseanalysisbypotentiometry
AT usregsrihandajani imprintedzeolitemodifiedcarbonpasteelectrodeasaselectivesensorforbloodglucoseanalysisbypotentiometry
AT mujiharsini imprintedzeolitemodifiedcarbonpasteelectrodeasaselectivesensorforbloodglucoseanalysisbypotentiometry
AT bahrotulilmiah imprintedzeolitemodifiedcarbonpasteelectrodeasaselectivesensorforbloodglucoseanalysisbypotentiometry
AT irenedindaoktavia imprintedzeolitemodifiedcarbonpasteelectrodeasaselectivesensorforbloodglucoseanalysisbypotentiometry
_version_ 1718394780923199488