Phasor-domain Dynamic Model of Asymmetric Current Injection Controller for Converter-interfaced Generator

This paper presents a controller model of asymmetric current injection for converter-interfaced generators suitable for root-mean-square (RMS) phasor-domain, fundamental-frequency, three-phase, and dynamic simulation tools. The effectiveness of the proposed controller is assessed with simulations in...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Victor A.F. Almeida, Glauco N. Taranto, Jose M. T. Marinho
Formato: article
Lenguaje:EN
Publicado: IEEE 2021
Materias:
Acceso en línea:https://doaj.org/article/e708a2842bd5437d9afa0b453af84e2a
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:e708a2842bd5437d9afa0b453af84e2a
record_format dspace
spelling oai:doaj.org-article:e708a2842bd5437d9afa0b453af84e2a2021-11-30T00:00:27ZPhasor-domain Dynamic Model of Asymmetric Current Injection Controller for Converter-interfaced Generator2196-542010.35833/MPCE.2021.000407https://doaj.org/article/e708a2842bd5437d9afa0b453af84e2a2021-01-01T00:00:00Zhttps://ieeexplore.ieee.org/document/9627869/https://doaj.org/toc/2196-5420This paper presents a controller model of asymmetric current injection for converter-interfaced generators suitable for root-mean-square (RMS) phasor-domain, fundamental-frequency, three-phase, and dynamic simulation tools. The effectiveness of the proposed controller is assessed with simulations in test systems with high percentage of converter-interfaced generation. The simulations focus on the operation of protection relays that use negative-sequence quantities in their directional elements. This paper also presents and compares two strategies to limit reactive negative-sequence currents, and active and reactive positive-sequence currents. A tutorial test system and a regional system part of the actual Brazilian Interconnected Power System are used to assess the correctness of the proposed controller in three-phase fundamental-frequency RMS dynamic simulations.Victor A.F. AlmeidaGlauco N. TarantoJose M. T. MarinhoIEEEarticleConverter-interfaced generatorthree-phase modelpower system protectionnegative-sequence current injectionnegative-sequence current protectionunbalanced faultProduction of electric energy or power. Powerplants. Central stationsTK1001-1841Renewable energy sourcesTJ807-830ENJournal of Modern Power Systems and Clean Energy, Vol 9, Iss 6, Pp 1269-1278 (2021)
institution DOAJ
collection DOAJ
language EN
topic Converter-interfaced generator
three-phase model
power system protection
negative-sequence current injection
negative-sequence current protection
unbalanced fault
Production of electric energy or power. Powerplants. Central stations
TK1001-1841
Renewable energy sources
TJ807-830
spellingShingle Converter-interfaced generator
three-phase model
power system protection
negative-sequence current injection
negative-sequence current protection
unbalanced fault
Production of electric energy or power. Powerplants. Central stations
TK1001-1841
Renewable energy sources
TJ807-830
Victor A.F. Almeida
Glauco N. Taranto
Jose M. T. Marinho
Phasor-domain Dynamic Model of Asymmetric Current Injection Controller for Converter-interfaced Generator
description This paper presents a controller model of asymmetric current injection for converter-interfaced generators suitable for root-mean-square (RMS) phasor-domain, fundamental-frequency, three-phase, and dynamic simulation tools. The effectiveness of the proposed controller is assessed with simulations in test systems with high percentage of converter-interfaced generation. The simulations focus on the operation of protection relays that use negative-sequence quantities in their directional elements. This paper also presents and compares two strategies to limit reactive negative-sequence currents, and active and reactive positive-sequence currents. A tutorial test system and a regional system part of the actual Brazilian Interconnected Power System are used to assess the correctness of the proposed controller in three-phase fundamental-frequency RMS dynamic simulations.
format article
author Victor A.F. Almeida
Glauco N. Taranto
Jose M. T. Marinho
author_facet Victor A.F. Almeida
Glauco N. Taranto
Jose M. T. Marinho
author_sort Victor A.F. Almeida
title Phasor-domain Dynamic Model of Asymmetric Current Injection Controller for Converter-interfaced Generator
title_short Phasor-domain Dynamic Model of Asymmetric Current Injection Controller for Converter-interfaced Generator
title_full Phasor-domain Dynamic Model of Asymmetric Current Injection Controller for Converter-interfaced Generator
title_fullStr Phasor-domain Dynamic Model of Asymmetric Current Injection Controller for Converter-interfaced Generator
title_full_unstemmed Phasor-domain Dynamic Model of Asymmetric Current Injection Controller for Converter-interfaced Generator
title_sort phasor-domain dynamic model of asymmetric current injection controller for converter-interfaced generator
publisher IEEE
publishDate 2021
url https://doaj.org/article/e708a2842bd5437d9afa0b453af84e2a
work_keys_str_mv AT victorafalmeida phasordomaindynamicmodelofasymmetriccurrentinjectioncontrollerforconverterinterfacedgenerator
AT glaucontaranto phasordomaindynamicmodelofasymmetriccurrentinjectioncontrollerforconverterinterfacedgenerator
AT josemtmarinho phasordomaindynamicmodelofasymmetriccurrentinjectioncontrollerforconverterinterfacedgenerator
_version_ 1718406896043425792