Reported insulin pump temperature fluctuations lack clinical relevance

Betsy B Dokken, Michael Rosinko Tandem Diabetes Care, Inc., San Diego, CA, USAIn their recent paper, Vereshchetin et al1 suggested that the heat generated by the Tandem Diabetes Care, Inc. (San Diego, CA, USA) t:slim® Insulin Pump during battery charging is high enough to d...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Dokken BB, Rosinko M
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2017
Materias:
Acceso en línea:https://doaj.org/article/e9204fb8f1434300837db48c61907241
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:e9204fb8f1434300837db48c61907241
record_format dspace
spelling oai:doaj.org-article:e9204fb8f1434300837db48c619072412021-12-02T04:12:25ZReported insulin pump temperature fluctuations lack clinical relevance1179-1470https://doaj.org/article/e9204fb8f1434300837db48c619072412017-02-01T00:00:00Zhttps://www.dovepress.com/reported-insulin-pump-temperature-fluctuations-lack-clinical-relevance-peer-reviewed-article-MDERhttps://doaj.org/toc/1179-1470Betsy B Dokken, Michael Rosinko Tandem Diabetes Care, Inc., San Diego, CA, USAIn their recent paper, Vereshchetin et al1 suggested that the heat generated by the Tandem Diabetes Care, Inc. (San Diego, CA, USA) t:slim® Insulin Pump during battery charging is high enough to degrade insulin. There are several reasons that the arguments made in this paper are not relevant to patient use of the t:slim Insulin Pump.View original paper by Vereshchetin et al.Dokken BBRosinko MDove Medical Pressarticleinsulin pumpMedical technologyR855-855.5ENMedical Devices: Evidence and Research, Vol Volume 10, Pp 43-46 (2017)
institution DOAJ
collection DOAJ
language EN
topic insulin pump
Medical technology
R855-855.5
spellingShingle insulin pump
Medical technology
R855-855.5
Dokken BB
Rosinko M
Reported insulin pump temperature fluctuations lack clinical relevance
description Betsy B Dokken, Michael Rosinko Tandem Diabetes Care, Inc., San Diego, CA, USAIn their recent paper, Vereshchetin et al1 suggested that the heat generated by the Tandem Diabetes Care, Inc. (San Diego, CA, USA) t:slim® Insulin Pump during battery charging is high enough to degrade insulin. There are several reasons that the arguments made in this paper are not relevant to patient use of the t:slim Insulin Pump.View original paper by Vereshchetin et al.
format article
author Dokken BB
Rosinko M
author_facet Dokken BB
Rosinko M
author_sort Dokken BB
title Reported insulin pump temperature fluctuations lack clinical relevance
title_short Reported insulin pump temperature fluctuations lack clinical relevance
title_full Reported insulin pump temperature fluctuations lack clinical relevance
title_fullStr Reported insulin pump temperature fluctuations lack clinical relevance
title_full_unstemmed Reported insulin pump temperature fluctuations lack clinical relevance
title_sort reported insulin pump temperature fluctuations lack clinical relevance
publisher Dove Medical Press
publishDate 2017
url https://doaj.org/article/e9204fb8f1434300837db48c61907241
work_keys_str_mv AT dokkenbb reportedinsulinpumptemperaturefluctuationslackclinicalrelevance
AT rosinkom reportedinsulinpumptemperaturefluctuationslackclinicalrelevance
_version_ 1718401402435272704