Using the linear damage summation hypothesis in the fatigue tests analysis of titanium alloy pieces

This paper presents the results of fatigue tests of titanium alloy, and also describes the use of the hypothesis of linear damage summation when processing the results of fatigue tests. Based on the experiments, the endurance limit of the titanium alloy was determined, which lies in the range from 4...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Gnatyuk Evgeniya, Skvortsov Arkadiy, Kuleshova Svetlana
Formato: article
Lenguaje:EN
Publicado: Institut za istrazivanja i projektovanja u privredi 2021
Materias:
T
Acceso en línea:https://doaj.org/article/e98d24bad44a4df5b8d30d1784a98a78
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:e98d24bad44a4df5b8d30d1784a98a78
record_format dspace
spelling oai:doaj.org-article:e98d24bad44a4df5b8d30d1784a98a782021-12-05T21:23:12ZUsing the linear damage summation hypothesis in the fatigue tests analysis of titanium alloy pieces1451-41171821-319710.5937/jaes0-30915https://doaj.org/article/e98d24bad44a4df5b8d30d1784a98a782021-01-01T00:00:00Zhttps://scindeks-clanci.ceon.rs/data/pdf/1451-4117/2021/1451-41172103586G.pdfhttps://doaj.org/toc/1451-4117https://doaj.org/toc/1821-3197This paper presents the results of fatigue tests of titanium alloy, and also describes the use of the hypothesis of linear damage summation when processing the results of fatigue tests. Based on the experiments, the endurance limit of the titanium alloy was determined, which lies in the range from 460 to 480 MPa with the number of cycles from 105 to 108. The purpose of the experiment was to determine the endurance limit of high-strength material, as well as a mathematical measurement of the expected destruction. In this study, empirical methods were used such as indirect observation of the object under study, description, and measurement of technical influences exerted on it by an artificial means, as well as linear regression analysis to establish the relationship between stress and durability. As a result of the experiment, fatigue curves were obtained for various probabilities, which give grounds to conclude that the use of the linear damage summation hypothesis in processing the results of fatigue tests entails a satisfactory practical accuracy of the calculation of endurance limit. This experiment is aimed at improving metal production by studying the quality of titanium alloy test pieces and performing mathematical analysis of possible problems arising in the process of its operational testing.Gnatyuk EvgeniyaSkvortsov ArkadiyKuleshova SvetlanaInstitut za istrazivanja i projektovanja u privrediarticleelastic deformationhigh strengthfatigue testsendurance limitregression analysisTechnologyTEngineering (General). Civil engineering (General)TA1-2040ENIstrazivanja i projektovanja za privredu, Vol 19, Iss 3, Pp 586-591 (2021)
institution DOAJ
collection DOAJ
language EN
topic elastic deformation
high strength
fatigue tests
endurance limit
regression analysis
Technology
T
Engineering (General). Civil engineering (General)
TA1-2040
spellingShingle elastic deformation
high strength
fatigue tests
endurance limit
regression analysis
Technology
T
Engineering (General). Civil engineering (General)
TA1-2040
Gnatyuk Evgeniya
Skvortsov Arkadiy
Kuleshova Svetlana
Using the linear damage summation hypothesis in the fatigue tests analysis of titanium alloy pieces
description This paper presents the results of fatigue tests of titanium alloy, and also describes the use of the hypothesis of linear damage summation when processing the results of fatigue tests. Based on the experiments, the endurance limit of the titanium alloy was determined, which lies in the range from 460 to 480 MPa with the number of cycles from 105 to 108. The purpose of the experiment was to determine the endurance limit of high-strength material, as well as a mathematical measurement of the expected destruction. In this study, empirical methods were used such as indirect observation of the object under study, description, and measurement of technical influences exerted on it by an artificial means, as well as linear regression analysis to establish the relationship between stress and durability. As a result of the experiment, fatigue curves were obtained for various probabilities, which give grounds to conclude that the use of the linear damage summation hypothesis in processing the results of fatigue tests entails a satisfactory practical accuracy of the calculation of endurance limit. This experiment is aimed at improving metal production by studying the quality of titanium alloy test pieces and performing mathematical analysis of possible problems arising in the process of its operational testing.
format article
author Gnatyuk Evgeniya
Skvortsov Arkadiy
Kuleshova Svetlana
author_facet Gnatyuk Evgeniya
Skvortsov Arkadiy
Kuleshova Svetlana
author_sort Gnatyuk Evgeniya
title Using the linear damage summation hypothesis in the fatigue tests analysis of titanium alloy pieces
title_short Using the linear damage summation hypothesis in the fatigue tests analysis of titanium alloy pieces
title_full Using the linear damage summation hypothesis in the fatigue tests analysis of titanium alloy pieces
title_fullStr Using the linear damage summation hypothesis in the fatigue tests analysis of titanium alloy pieces
title_full_unstemmed Using the linear damage summation hypothesis in the fatigue tests analysis of titanium alloy pieces
title_sort using the linear damage summation hypothesis in the fatigue tests analysis of titanium alloy pieces
publisher Institut za istrazivanja i projektovanja u privredi
publishDate 2021
url https://doaj.org/article/e98d24bad44a4df5b8d30d1784a98a78
work_keys_str_mv AT gnatyukevgeniya usingthelineardamagesummationhypothesisinthefatiguetestsanalysisoftitaniumalloypieces
AT skvortsovarkadiy usingthelineardamagesummationhypothesisinthefatiguetestsanalysisoftitaniumalloypieces
AT kuleshovasvetlana usingthelineardamagesummationhypothesisinthefatiguetestsanalysisoftitaniumalloypieces
_version_ 1718371038501273600