Studies of acute and subchronic systemic toxicity associated with a copper/low-density polyethylene nanocomposite intrauterine device

Li-Xia Hu,1,* Shi-Fu Hu,2,* Meng Rao,2,3 Jing Yang,2,4 Hui Lei,2,5 Zhuo Duan,6 Wei Xia,2,7 Changhong Zhu2,7 1Department of Histology and Embryology, Preclinical Medicine College, Xinxiang Medical University, Xinxiang, Henan, People’s Republic of China; 2Family Planning Research I...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Hu LX, Hu SF, Rao M, Yang J, Lei H, Duan Z, Xia W, Zhu C
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2018
Materias:
Acceso en línea:https://doaj.org/article/ea2117aa092a4db19ef7e0134fa7c913
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:ea2117aa092a4db19ef7e0134fa7c913
record_format dspace
spelling oai:doaj.org-article:ea2117aa092a4db19ef7e0134fa7c9132021-12-02T03:31:19ZStudies of acute and subchronic systemic toxicity associated with a copper/low-density polyethylene nanocomposite intrauterine device1178-2013https://doaj.org/article/ea2117aa092a4db19ef7e0134fa7c9132018-08-01T00:00:00Zhttps://www.dovepress.com/studies-of-acute-and-subchronic-systemic-toxicity-associated-with-a-co-peer-reviewed-article-IJNhttps://doaj.org/toc/1178-2013Li-Xia Hu,1,* Shi-Fu Hu,2,* Meng Rao,2,3 Jing Yang,2,4 Hui Lei,2,5 Zhuo Duan,6 Wei Xia,2,7 Changhong Zhu2,7 1Department of Histology and Embryology, Preclinical Medicine College, Xinxiang Medical University, Xinxiang, Henan, People’s Republic of China; 2Family Planning Research Institute, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, People’s Republic of China; 3Department of Reproduction and Genetics, the First Affiliated Hospital of Kunming Medical University, Kunming, Yunnan, People’s Republic of China; 4Department of Gynecology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan, People’s Republic of China; 5Department of Gynaecology and Obstetrics, Taikang Tongji Hospital, Wuhan, Hubei, People’s Republic of China; 6Dayu Medical Devices Co., Ltd., Jingzhou, Hubei, People’s Republic of China; 7Reproductive Medicine Center, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, People’s Republic of China *These authors contributed equally to this work Introduction: The physiologic safety of devices and materials intended for clinical implantation should be evaluated. This study, a logical extension of our previous work, aimed to investigate the safety of a novel contraceptive device, the copper/low-density polyethylene nanocomposite intrauterine device (nano-Cu/LDPE IUD), through studies of its potential toxicity after acute and subchronic administration in mice and rats. Methods: For the acute toxicity study, single 50 mL/kg doses of nano-Cu/LDPE IUD extracts were administered to mice via intravenous or intraperitoneal injection. General behavioral adverse effects, mortality, and body weights were evaluated for up to 72 hours. In the 13-week subchronic toxicity study, the nano-Cu/LDPE composite with 10-fold higher than the standard clinical dose was implanted subcutaneously into the dorsal skin of Wistar rats. The control group underwent a sham procedure without material insertion. Results: During all acute study observation times, the biologic reactions of the mice in the nano-Cu/LDPE group did not differ from those observed in the control group. The groups did not differ statistically in terms of body weight gain, and no macroscopic changes were observed in any organs. In the subchronic study, no clinical signs of toxicity or mortality were observed in either the nano-Cu/LDPE or control group during the 13-week period. The nano-Cu/LDPE composite did not cause any alterations in body weight, food consumption, hematologic and biochemical parameters, or organ weight relative to the control for any observed sample group. Histopathologic examinations of the organs revealed normal architecture, indicating that the inserted material did not cause morphologic disturbances in the rats. Conclusion: Overall, the results indicate that the nano-Cu/LDPE IUD did not induce systemic toxicity under experimental conditions of the recommended standard practices, suggesting that the novel material IUD is safe and feasible for future contraceptive applications. Keywords: intrauterine device, copper/low-density polyethylene nanocomposite intrauterine device, acute toxicity, subchronic toxicityHu LXHu SFRao MYang JLei HDuan ZXia WZhu CDove Medical Pressarticleintrauterine devicecopper/low-density polyethylene nanocomposite intrauterine deviceacute toxicitysub-chronic toxicityMedicine (General)R5-920ENInternational Journal of Nanomedicine, Vol Volume 13, Pp 4913-4926 (2018)
institution DOAJ
collection DOAJ
language EN
topic intrauterine device
copper/low-density polyethylene nanocomposite intrauterine device
acute toxicity
sub-chronic toxicity
Medicine (General)
R5-920
spellingShingle intrauterine device
copper/low-density polyethylene nanocomposite intrauterine device
acute toxicity
sub-chronic toxicity
Medicine (General)
R5-920
Hu LX
Hu SF
Rao M
Yang J
Lei H
Duan Z
Xia W
Zhu C
Studies of acute and subchronic systemic toxicity associated with a copper/low-density polyethylene nanocomposite intrauterine device
description Li-Xia Hu,1,* Shi-Fu Hu,2,* Meng Rao,2,3 Jing Yang,2,4 Hui Lei,2,5 Zhuo Duan,6 Wei Xia,2,7 Changhong Zhu2,7 1Department of Histology and Embryology, Preclinical Medicine College, Xinxiang Medical University, Xinxiang, Henan, People’s Republic of China; 2Family Planning Research Institute, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, People’s Republic of China; 3Department of Reproduction and Genetics, the First Affiliated Hospital of Kunming Medical University, Kunming, Yunnan, People’s Republic of China; 4Department of Gynecology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan, People’s Republic of China; 5Department of Gynaecology and Obstetrics, Taikang Tongji Hospital, Wuhan, Hubei, People’s Republic of China; 6Dayu Medical Devices Co., Ltd., Jingzhou, Hubei, People’s Republic of China; 7Reproductive Medicine Center, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, People’s Republic of China *These authors contributed equally to this work Introduction: The physiologic safety of devices and materials intended for clinical implantation should be evaluated. This study, a logical extension of our previous work, aimed to investigate the safety of a novel contraceptive device, the copper/low-density polyethylene nanocomposite intrauterine device (nano-Cu/LDPE IUD), through studies of its potential toxicity after acute and subchronic administration in mice and rats. Methods: For the acute toxicity study, single 50 mL/kg doses of nano-Cu/LDPE IUD extracts were administered to mice via intravenous or intraperitoneal injection. General behavioral adverse effects, mortality, and body weights were evaluated for up to 72 hours. In the 13-week subchronic toxicity study, the nano-Cu/LDPE composite with 10-fold higher than the standard clinical dose was implanted subcutaneously into the dorsal skin of Wistar rats. The control group underwent a sham procedure without material insertion. Results: During all acute study observation times, the biologic reactions of the mice in the nano-Cu/LDPE group did not differ from those observed in the control group. The groups did not differ statistically in terms of body weight gain, and no macroscopic changes were observed in any organs. In the subchronic study, no clinical signs of toxicity or mortality were observed in either the nano-Cu/LDPE or control group during the 13-week period. The nano-Cu/LDPE composite did not cause any alterations in body weight, food consumption, hematologic and biochemical parameters, or organ weight relative to the control for any observed sample group. Histopathologic examinations of the organs revealed normal architecture, indicating that the inserted material did not cause morphologic disturbances in the rats. Conclusion: Overall, the results indicate that the nano-Cu/LDPE IUD did not induce systemic toxicity under experimental conditions of the recommended standard practices, suggesting that the novel material IUD is safe and feasible for future contraceptive applications. Keywords: intrauterine device, copper/low-density polyethylene nanocomposite intrauterine device, acute toxicity, subchronic toxicity
format article
author Hu LX
Hu SF
Rao M
Yang J
Lei H
Duan Z
Xia W
Zhu C
author_facet Hu LX
Hu SF
Rao M
Yang J
Lei H
Duan Z
Xia W
Zhu C
author_sort Hu LX
title Studies of acute and subchronic systemic toxicity associated with a copper/low-density polyethylene nanocomposite intrauterine device
title_short Studies of acute and subchronic systemic toxicity associated with a copper/low-density polyethylene nanocomposite intrauterine device
title_full Studies of acute and subchronic systemic toxicity associated with a copper/low-density polyethylene nanocomposite intrauterine device
title_fullStr Studies of acute and subchronic systemic toxicity associated with a copper/low-density polyethylene nanocomposite intrauterine device
title_full_unstemmed Studies of acute and subchronic systemic toxicity associated with a copper/low-density polyethylene nanocomposite intrauterine device
title_sort studies of acute and subchronic systemic toxicity associated with a copper/low-density polyethylene nanocomposite intrauterine device
publisher Dove Medical Press
publishDate 2018
url https://doaj.org/article/ea2117aa092a4db19ef7e0134fa7c913
work_keys_str_mv AT hulx studiesofacuteandsubchronicsystemictoxicityassociatedwithacopperlowdensitypolyethylenenanocompositeintrauterinedevice
AT husf studiesofacuteandsubchronicsystemictoxicityassociatedwithacopperlowdensitypolyethylenenanocompositeintrauterinedevice
AT raom studiesofacuteandsubchronicsystemictoxicityassociatedwithacopperlowdensitypolyethylenenanocompositeintrauterinedevice
AT yangj studiesofacuteandsubchronicsystemictoxicityassociatedwithacopperlowdensitypolyethylenenanocompositeintrauterinedevice
AT leih studiesofacuteandsubchronicsystemictoxicityassociatedwithacopperlowdensitypolyethylenenanocompositeintrauterinedevice
AT duanz studiesofacuteandsubchronicsystemictoxicityassociatedwithacopperlowdensitypolyethylenenanocompositeintrauterinedevice
AT xiaw studiesofacuteandsubchronicsystemictoxicityassociatedwithacopperlowdensitypolyethylenenanocompositeintrauterinedevice
AT zhuc studiesofacuteandsubchronicsystemictoxicityassociatedwithacopperlowdensitypolyethylenenanocompositeintrauterinedevice
_version_ 1718401766128615424