Atypical start-up experiments on pump as turbine

At present, research on the characteristics of pumps as turbine (PATs) during the start-up process is still insufficient. To reveal the transient characteristics of a centrifugal PAT during the atypical start-up process, a test rig for the transient performance of the PAT was built; in addition, exp...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Yu-Liang Zhang, Yan-Juan Zhao
Formato: article
Lenguaje:EN
Publicado: SAGE Publishing 2021
Materias:
Acceso en línea:https://doaj.org/article/ea551cdc795a42d0b439772d5432d3dd
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:ea551cdc795a42d0b439772d5432d3dd
record_format dspace
spelling oai:doaj.org-article:ea551cdc795a42d0b439772d5432d3dd2021-12-02T03:33:44ZAtypical start-up experiments on pump as turbine1687-814010.1177/16878140211062716https://doaj.org/article/ea551cdc795a42d0b439772d5432d3dd2021-11-01T00:00:00Zhttps://doi.org/10.1177/16878140211062716https://doaj.org/toc/1687-8140At present, research on the characteristics of pumps as turbine (PATs) during the start-up process is still insufficient. To reveal the transient characteristics of a centrifugal PAT during the atypical start-up process, a test rig for the transient performance of the PAT was built; in addition, experiments on the transient hydraulic performance of three kinds of steady speed and three kinds of steady flow were conducted. Through these experiments, the evolution characteristics of the transient performance parameters of the PAT during the atypical start-up process were analyzed over time. Moreover, three dimensionless coefficients were employed to deeply reveal the transient characteristics of the PAT during atypical start-up. Results showed that the rise curves of flow rate and outlet static pressure exhibited shock phenomena. With the increase in the stable running speed after start-up, the impact phenomenon of the outlet static pressure presented a delayed trend. The dimensionless head and flow coefficients reached the maximum value at the initial stage of the atypical start-up process and then rapidly dropped to the minimum value before slowly rising to the final stable value. The dimensionless power coefficient had a maximum value at the initial stage of atypical start-up and then rapidly dropped to the final stable value.Yu-Liang ZhangYan-Juan ZhaoSAGE PublishingarticleMechanical engineering and machineryTJ1-1570ENAdvances in Mechanical Engineering, Vol 13 (2021)
institution DOAJ
collection DOAJ
language EN
topic Mechanical engineering and machinery
TJ1-1570
spellingShingle Mechanical engineering and machinery
TJ1-1570
Yu-Liang Zhang
Yan-Juan Zhao
Atypical start-up experiments on pump as turbine
description At present, research on the characteristics of pumps as turbine (PATs) during the start-up process is still insufficient. To reveal the transient characteristics of a centrifugal PAT during the atypical start-up process, a test rig for the transient performance of the PAT was built; in addition, experiments on the transient hydraulic performance of three kinds of steady speed and three kinds of steady flow were conducted. Through these experiments, the evolution characteristics of the transient performance parameters of the PAT during the atypical start-up process were analyzed over time. Moreover, three dimensionless coefficients were employed to deeply reveal the transient characteristics of the PAT during atypical start-up. Results showed that the rise curves of flow rate and outlet static pressure exhibited shock phenomena. With the increase in the stable running speed after start-up, the impact phenomenon of the outlet static pressure presented a delayed trend. The dimensionless head and flow coefficients reached the maximum value at the initial stage of the atypical start-up process and then rapidly dropped to the minimum value before slowly rising to the final stable value. The dimensionless power coefficient had a maximum value at the initial stage of atypical start-up and then rapidly dropped to the final stable value.
format article
author Yu-Liang Zhang
Yan-Juan Zhao
author_facet Yu-Liang Zhang
Yan-Juan Zhao
author_sort Yu-Liang Zhang
title Atypical start-up experiments on pump as turbine
title_short Atypical start-up experiments on pump as turbine
title_full Atypical start-up experiments on pump as turbine
title_fullStr Atypical start-up experiments on pump as turbine
title_full_unstemmed Atypical start-up experiments on pump as turbine
title_sort atypical start-up experiments on pump as turbine
publisher SAGE Publishing
publishDate 2021
url https://doaj.org/article/ea551cdc795a42d0b439772d5432d3dd
work_keys_str_mv AT yuliangzhang atypicalstartupexperimentsonpumpasturbine
AT yanjuanzhao atypicalstartupexperimentsonpumpasturbine
_version_ 1718401766361399296