Examination of the Quality of the Manual Pre-Sterilization Processing of Dental Instruments Using Benzidine Test

The risk of infections in dental practices has been attracting for decades the interest of researchers from all over the world. A serious problem related to the transmission of blood-borne viruses is the thorough removal of organic matter, and mainly blood, from dental instruments when performing ma...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Stoeva V., Kevorkyan A., Raycheva R., Kondeva V., Stoilova Y.
Formato: article
Lenguaje:EN
Publicado: Sciendo 2016
Materias:
R
Acceso en línea:https://doaj.org/article/eb092ca29d104628b2230a87d4bfeaf9
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:eb092ca29d104628b2230a87d4bfeaf9
record_format dspace
spelling oai:doaj.org-article:eb092ca29d104628b2230a87d4bfeaf92021-12-02T19:11:12ZExamination of the Quality of the Manual Pre-Sterilization Processing of Dental Instruments Using Benzidine Test0324-175010.1515/amb-2016-0017https://doaj.org/article/eb092ca29d104628b2230a87d4bfeaf92016-10-01T00:00:00Zhttps://doi.org/10.1515/amb-2016-0017https://doaj.org/toc/0324-1750The risk of infections in dental practices has been attracting for decades the interest of researchers from all over the world. A serious problem related to the transmission of blood-borne viruses is the thorough removal of organic matter, and mainly blood, from dental instruments when performing manual pre-sterilization decontamination. Application of benzidine test to prove the presence of blood traces on large and small dental instruments prepared for sterilization for the purpose of assessing the quality of the manual pre-sterilization decontamination. A total of 485 benzidine tests had been performed on selected 205 large and 280 small dental instruments visibly contaminated with blood. Of the total of 485 tested samples, blood traces were found in 63 (12.99 ± 1.53%). In the group of large instruments, positive benzidine test was obtained in 7.80% compared to 16.78% in the small instruments with the difference being statistically significant (p = 0.003). All 63 positive samples were additionally processed using ultrasound. Blood traces were found in 8 instruments with all of the positive samples being obtained from the barbed broaches. The manual cleaning does not guarantee decontamination of the dental instruments unlike the ultrasonic cleaning where any blood traces are being completely removed from the large instruments. In terms of the small instruments, there are still blood traces present after the ultrasonic cleaning which requires for it to be combined with a suitable enzyme cleaner, and the barbed broaches, as a requirement, should be used on a disposable basis.Stoeva V.Kevorkyan A.Raycheva R.Kondeva V.Stoilova Y.Sciendoarticlebenzidine testlarge and small dental instrumentsmanual pre-sterilization decontaminationMedicineRENActa Medica Bulgarica, Vol 43, Iss 2, Pp 52-60 (2016)
institution DOAJ
collection DOAJ
language EN
topic benzidine test
large and small dental instruments
manual pre-sterilization decontamination
Medicine
R
spellingShingle benzidine test
large and small dental instruments
manual pre-sterilization decontamination
Medicine
R
Stoeva V.
Kevorkyan A.
Raycheva R.
Kondeva V.
Stoilova Y.
Examination of the Quality of the Manual Pre-Sterilization Processing of Dental Instruments Using Benzidine Test
description The risk of infections in dental practices has been attracting for decades the interest of researchers from all over the world. A serious problem related to the transmission of blood-borne viruses is the thorough removal of organic matter, and mainly blood, from dental instruments when performing manual pre-sterilization decontamination. Application of benzidine test to prove the presence of blood traces on large and small dental instruments prepared for sterilization for the purpose of assessing the quality of the manual pre-sterilization decontamination. A total of 485 benzidine tests had been performed on selected 205 large and 280 small dental instruments visibly contaminated with blood. Of the total of 485 tested samples, blood traces were found in 63 (12.99 ± 1.53%). In the group of large instruments, positive benzidine test was obtained in 7.80% compared to 16.78% in the small instruments with the difference being statistically significant (p = 0.003). All 63 positive samples were additionally processed using ultrasound. Blood traces were found in 8 instruments with all of the positive samples being obtained from the barbed broaches. The manual cleaning does not guarantee decontamination of the dental instruments unlike the ultrasonic cleaning where any blood traces are being completely removed from the large instruments. In terms of the small instruments, there are still blood traces present after the ultrasonic cleaning which requires for it to be combined with a suitable enzyme cleaner, and the barbed broaches, as a requirement, should be used on a disposable basis.
format article
author Stoeva V.
Kevorkyan A.
Raycheva R.
Kondeva V.
Stoilova Y.
author_facet Stoeva V.
Kevorkyan A.
Raycheva R.
Kondeva V.
Stoilova Y.
author_sort Stoeva V.
title Examination of the Quality of the Manual Pre-Sterilization Processing of Dental Instruments Using Benzidine Test
title_short Examination of the Quality of the Manual Pre-Sterilization Processing of Dental Instruments Using Benzidine Test
title_full Examination of the Quality of the Manual Pre-Sterilization Processing of Dental Instruments Using Benzidine Test
title_fullStr Examination of the Quality of the Manual Pre-Sterilization Processing of Dental Instruments Using Benzidine Test
title_full_unstemmed Examination of the Quality of the Manual Pre-Sterilization Processing of Dental Instruments Using Benzidine Test
title_sort examination of the quality of the manual pre-sterilization processing of dental instruments using benzidine test
publisher Sciendo
publishDate 2016
url https://doaj.org/article/eb092ca29d104628b2230a87d4bfeaf9
work_keys_str_mv AT stoevav examinationofthequalityofthemanualpresterilizationprocessingofdentalinstrumentsusingbenzidinetest
AT kevorkyana examinationofthequalityofthemanualpresterilizationprocessingofdentalinstrumentsusingbenzidinetest
AT raychevar examinationofthequalityofthemanualpresterilizationprocessingofdentalinstrumentsusingbenzidinetest
AT kondevav examinationofthequalityofthemanualpresterilizationprocessingofdentalinstrumentsusingbenzidinetest
AT stoilovay examinationofthequalityofthemanualpresterilizationprocessingofdentalinstrumentsusingbenzidinetest
_version_ 1718377122212347904