Safety in residential buildings: Evacuation from residential buildings without fire escape stairs
Introduction/purpose: Safety in high residential buildings presents a very important and always actual task. In case of some unforeseen and dangerous occurrences, their residents must be evacuated. Fire, earthquakes, and terrorism are only some of such situations. The speed of evacuation from hi...
Guardado en:
Autor principal: | |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
University of Defence in Belgrade
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/ebf72f9b8d644290867b8231efc3eec4 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:ebf72f9b8d644290867b8231efc3eec4 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:ebf72f9b8d644290867b8231efc3eec42021-12-02T14:39:52ZSafety in residential buildings: Evacuation from residential buildings without fire escape stairs10.5937/vojtehg69-281700042-84692217-4753https://doaj.org/article/ebf72f9b8d644290867b8231efc3eec42021-01-01T00:00:00Zhttps://scindeks-clanci.ceon.rs/data/pdf/0042-8469/2021/0042-84692101148J.pdfhttps://doaj.org/toc/0042-8469https://doaj.org/toc/2217-4753Introduction/purpose: Safety in high residential buildings presents a very important and always actual task. In case of some unforeseen and dangerous occurrences, their residents must be evacuated. Fire, earthquakes, and terrorism are only some of such situations. The speed of evacuation from high residential buildings depends on many different factors. A particularly difficult and complex evacuation task concerns buildings without fire escape stairs. Methods: The modeling method was used in this paper. Based on a real object – a residential building, an appropriate simulation model was realized in appropriate simulation software. Results: The results of this paper have shown that, out of four scenarios, the fastest evacuation was for the evacuation speed of 1.75 m/s. The first two scenarios did not report any jams, unlike the third and fourth scenario; in the third scenario, the occupants' speeds were 0.75 m/s and 1.25 m/s while in the fourth scenario, the simulated occupants' speeds were from 0.75 m/s to 1.75 m/s. Conclusion: The usage of appropriate simulation software enables fast, precise, safe and cheаp calculation of evacuation times and it can significantly improve evacuation procedures and evacuation strategies.Radoje B. Jevtić University of Defence in BelgradearticleevacuationbuildinghumansimulationMilitary ScienceUEngineering (General). Civil engineering (General)TA1-2040ENVojnotehnički Glasnik, Vol 69, Iss 1, Pp 148-178 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
evacuation building human simulation Military Science U Engineering (General). Civil engineering (General) TA1-2040 |
spellingShingle |
evacuation building human simulation Military Science U Engineering (General). Civil engineering (General) TA1-2040 Radoje B. Jevtić Safety in residential buildings: Evacuation from residential buildings without fire escape stairs |
description |
Introduction/purpose: Safety in high residential buildings presents a very
important and always actual task. In case of some unforeseen and
dangerous occurrences, their residents must be evacuated. Fire,
earthquakes, and terrorism are only some of such situations. The speed of
evacuation from high residential buildings depends on many different
factors. A particularly difficult and complex evacuation task concerns
buildings without fire escape stairs.
Methods: The modeling method was used in this paper. Based on a real
object – a residential building, an appropriate simulation model was
realized in appropriate simulation software.
Results: The results of this paper have shown that, out of four scenarios,
the fastest evacuation was for the evacuation speed of 1.75 m/s. The first
two scenarios did not report any jams, unlike the third and fourth scenario;
in the third scenario, the occupants' speeds were 0.75 m/s and 1.25 m/s
while in the fourth scenario, the simulated occupants' speeds were from
0.75 m/s to 1.75 m/s.
Conclusion: The usage of appropriate simulation software enables fast,
precise, safe and cheаp calculation of evacuation times and it can
significantly improve evacuation procedures and evacuation strategies. |
format |
article |
author |
Radoje B. Jevtić |
author_facet |
Radoje B. Jevtić |
author_sort |
Radoje B. Jevtić |
title |
Safety in residential buildings: Evacuation from residential buildings without fire escape stairs |
title_short |
Safety in residential buildings: Evacuation from residential buildings without fire escape stairs |
title_full |
Safety in residential buildings: Evacuation from residential buildings without fire escape stairs |
title_fullStr |
Safety in residential buildings: Evacuation from residential buildings without fire escape stairs |
title_full_unstemmed |
Safety in residential buildings: Evacuation from residential buildings without fire escape stairs |
title_sort |
safety in residential buildings: evacuation from residential buildings without fire escape stairs |
publisher |
University of Defence in Belgrade |
publishDate |
2021 |
url |
https://doaj.org/article/ebf72f9b8d644290867b8231efc3eec4 |
work_keys_str_mv |
AT radojebjevtic safetyinresidentialbuildingsevacuationfromresidentialbuildingswithoutfireescapestairs |
_version_ |
1718390510942420992 |