Rapid mapping of polarization switching through complete information acquisition
Resolution of classical piezoresponse force microscopy is limited in data acquisition rates and energy scales. Here, Somnath et al. report an approach for rapid probing of ferroelectric switching using direct strain detection of material response to probe bias, enabling spectroscopic imaging at a ra...
Guardado en:
Autores principales: | , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Nature Portfolio
2016
|
Materias: | |
Acceso en línea: | https://doaj.org/article/ec03e4f8c01f4fc8844c9950b35230a0 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:ec03e4f8c01f4fc8844c9950b35230a0 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:ec03e4f8c01f4fc8844c9950b35230a02021-12-02T16:56:45ZRapid mapping of polarization switching through complete information acquisition10.1038/ncomms132902041-1723https://doaj.org/article/ec03e4f8c01f4fc8844c9950b35230a02016-12-01T00:00:00Zhttps://doi.org/10.1038/ncomms13290https://doaj.org/toc/2041-1723Resolution of classical piezoresponse force microscopy is limited in data acquisition rates and energy scales. Here, Somnath et al. report an approach for rapid probing of ferroelectric switching using direct strain detection of material response to probe bias, enabling spectroscopic imaging at a rate of 3,504 times faster the current state of the art.Suhas SomnathAlex BelianinovSergei V. KalininStephen JesseNature PortfolioarticleScienceQENNature Communications, Vol 7, Iss 1, Pp 1-8 (2016) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Science Q |
spellingShingle |
Science Q Suhas Somnath Alex Belianinov Sergei V. Kalinin Stephen Jesse Rapid mapping of polarization switching through complete information acquisition |
description |
Resolution of classical piezoresponse force microscopy is limited in data acquisition rates and energy scales. Here, Somnath et al. report an approach for rapid probing of ferroelectric switching using direct strain detection of material response to probe bias, enabling spectroscopic imaging at a rate of 3,504 times faster the current state of the art. |
format |
article |
author |
Suhas Somnath Alex Belianinov Sergei V. Kalinin Stephen Jesse |
author_facet |
Suhas Somnath Alex Belianinov Sergei V. Kalinin Stephen Jesse |
author_sort |
Suhas Somnath |
title |
Rapid mapping of polarization switching through complete information acquisition |
title_short |
Rapid mapping of polarization switching through complete information acquisition |
title_full |
Rapid mapping of polarization switching through complete information acquisition |
title_fullStr |
Rapid mapping of polarization switching through complete information acquisition |
title_full_unstemmed |
Rapid mapping of polarization switching through complete information acquisition |
title_sort |
rapid mapping of polarization switching through complete information acquisition |
publisher |
Nature Portfolio |
publishDate |
2016 |
url |
https://doaj.org/article/ec03e4f8c01f4fc8844c9950b35230a0 |
work_keys_str_mv |
AT suhassomnath rapidmappingofpolarizationswitchingthroughcompleteinformationacquisition AT alexbelianinov rapidmappingofpolarizationswitchingthroughcompleteinformationacquisition AT sergeivkalinin rapidmappingofpolarizationswitchingthroughcompleteinformationacquisition AT stephenjesse rapidmappingofpolarizationswitchingthroughcompleteinformationacquisition |
_version_ |
1718382774256140288 |