Is there a difference in venous thrombosis rate in free flap anastomoses based on coupler diameter? A systematic review. Does Size Really Matter?

Background: The adage is to use the largest anastomotic coupler device (coupler) size possible, since smaller an anastomosis might be more susceptible to thrombosis. It is unclear if this wisdom is supported by data. This study tests the hypothesis that there is no difference in the reported literat...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: D.D. Krijgh, B. Tellier, T. Teunis, W. Maarse, J.H. Coert
Formato: article
Lenguaje:EN
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://doaj.org/article/edc7e7d978a14da6ac6a68337cbed9b7
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:edc7e7d978a14da6ac6a68337cbed9b7
record_format dspace
spelling oai:doaj.org-article:edc7e7d978a14da6ac6a68337cbed9b72021-12-02T05:02:02ZIs there a difference in venous thrombosis rate in free flap anastomoses based on coupler diameter? A systematic review. Does Size Really Matter?2352-587810.1016/j.jpra.2021.07.005https://doaj.org/article/edc7e7d978a14da6ac6a68337cbed9b72021-12-01T00:00:00Zhttp://www.sciencedirect.com/science/article/pii/S2352587821000668https://doaj.org/toc/2352-5878Background: The adage is to use the largest anastomotic coupler device (coupler) size possible, since smaller an anastomosis might be more susceptible to thrombosis. It is unclear if this wisdom is supported by data. This study tests the hypothesis that there is no difference in the reported literature in thrombosis rate between different coupler sizes. Methods: We searched PubMed, Embase, and the Cochrane Library. After screening 235 studies, we included 11 retrospective case-series. According to the criteria of Newcastle–Ottowa Scale, quality score ranged from 2 to 4 (out of 5) and funnel plots indicated publication bias. We included a total of 5930 coupled anastomoses. We calculated thrombosis rate per coupler diameter with exact confidence intervals (CIs). We regard non-overlapping CIs as a significant difference. Results: Nine studies reported no difference in thrombosis rate based on coupler size. Two studies report a potentially greater thrombosis rates in smaller sizes: (1) 2.0 mm 27% (95% CI 17%–40%, 17/62 cases) vs. 3.0 mm 6.3% (95% CI 2.8%–12%, 8/126 cases) and (2) 1.5 mm 6.9% (95% CI 2.8%–14%, 7/101 cases) vs. 3.0 mm group 1.2% (95% CI 0.64%–2.1%, 13/1079). Conclusion: There is some evidence that suggests that smaller coupler sizes are associated with greater thrombosis rate, but the current available evidence has limitations. Performing a second anastomosis, in case, the first anastomosis is performed with a coupler size of 1.0, 1.5, or even 2.0 mm, can potentially reduce this rate, however, this remains to be determined.D.D. KrijghB. TellierT. TeunisW. MaarseJ.H. CoertElsevierarticleThrombosisAnastomotic Coupler DeviceMicrosurgerySurgeryRD1-811ENJPRAS Open, Vol 30, Iss , Pp 74-83 (2021)
institution DOAJ
collection DOAJ
language EN
topic Thrombosis
Anastomotic Coupler Device
Microsurgery
Surgery
RD1-811
spellingShingle Thrombosis
Anastomotic Coupler Device
Microsurgery
Surgery
RD1-811
D.D. Krijgh
B. Tellier
T. Teunis
W. Maarse
J.H. Coert
Is there a difference in venous thrombosis rate in free flap anastomoses based on coupler diameter? A systematic review. Does Size Really Matter?
description Background: The adage is to use the largest anastomotic coupler device (coupler) size possible, since smaller an anastomosis might be more susceptible to thrombosis. It is unclear if this wisdom is supported by data. This study tests the hypothesis that there is no difference in the reported literature in thrombosis rate between different coupler sizes. Methods: We searched PubMed, Embase, and the Cochrane Library. After screening 235 studies, we included 11 retrospective case-series. According to the criteria of Newcastle–Ottowa Scale, quality score ranged from 2 to 4 (out of 5) and funnel plots indicated publication bias. We included a total of 5930 coupled anastomoses. We calculated thrombosis rate per coupler diameter with exact confidence intervals (CIs). We regard non-overlapping CIs as a significant difference. Results: Nine studies reported no difference in thrombosis rate based on coupler size. Two studies report a potentially greater thrombosis rates in smaller sizes: (1) 2.0 mm 27% (95% CI 17%–40%, 17/62 cases) vs. 3.0 mm 6.3% (95% CI 2.8%–12%, 8/126 cases) and (2) 1.5 mm 6.9% (95% CI 2.8%–14%, 7/101 cases) vs. 3.0 mm group 1.2% (95% CI 0.64%–2.1%, 13/1079). Conclusion: There is some evidence that suggests that smaller coupler sizes are associated with greater thrombosis rate, but the current available evidence has limitations. Performing a second anastomosis, in case, the first anastomosis is performed with a coupler size of 1.0, 1.5, or even 2.0 mm, can potentially reduce this rate, however, this remains to be determined.
format article
author D.D. Krijgh
B. Tellier
T. Teunis
W. Maarse
J.H. Coert
author_facet D.D. Krijgh
B. Tellier
T. Teunis
W. Maarse
J.H. Coert
author_sort D.D. Krijgh
title Is there a difference in venous thrombosis rate in free flap anastomoses based on coupler diameter? A systematic review. Does Size Really Matter?
title_short Is there a difference in venous thrombosis rate in free flap anastomoses based on coupler diameter? A systematic review. Does Size Really Matter?
title_full Is there a difference in venous thrombosis rate in free flap anastomoses based on coupler diameter? A systematic review. Does Size Really Matter?
title_fullStr Is there a difference in venous thrombosis rate in free flap anastomoses based on coupler diameter? A systematic review. Does Size Really Matter?
title_full_unstemmed Is there a difference in venous thrombosis rate in free flap anastomoses based on coupler diameter? A systematic review. Does Size Really Matter?
title_sort is there a difference in venous thrombosis rate in free flap anastomoses based on coupler diameter? a systematic review. does size really matter?
publisher Elsevier
publishDate 2021
url https://doaj.org/article/edc7e7d978a14da6ac6a68337cbed9b7
work_keys_str_mv AT ddkrijgh isthereadifferenceinvenousthrombosisrateinfreeflapanastomosesbasedoncouplerdiameterasystematicreviewdoessizereallymatter
AT btellier isthereadifferenceinvenousthrombosisrateinfreeflapanastomosesbasedoncouplerdiameterasystematicreviewdoessizereallymatter
AT tteunis isthereadifferenceinvenousthrombosisrateinfreeflapanastomosesbasedoncouplerdiameterasystematicreviewdoessizereallymatter
AT wmaarse isthereadifferenceinvenousthrombosisrateinfreeflapanastomosesbasedoncouplerdiameterasystematicreviewdoessizereallymatter
AT jhcoert isthereadifferenceinvenousthrombosisrateinfreeflapanastomosesbasedoncouplerdiameterasystematicreviewdoessizereallymatter
_version_ 1718400804608540672