Assessment of Cumulative Radiation Dose of Neonate Hospitalized in Intensive Care Units
BACKGROUND AND OBJECTIVE: Newborns admitted to the neonatal intensive care unit (NICU) , would be undergo a large number of X-ray imaging due to their involvement with various diseases The most important complication of receiving too much X-rays is an increased risk of various cancers. The aim of th...
Guardado en:
Autores principales: | , , , |
---|---|
Formato: | article |
Lenguaje: | EN FA |
Publicado: |
Babol University of Medical Sciences
2020
|
Materias: | |
Acceso en línea: | https://doaj.org/article/edfc790f303d40218f180760051f44ae |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:edfc790f303d40218f180760051f44ae |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:edfc790f303d40218f180760051f44ae2021-11-09T10:15:55ZAssessment of Cumulative Radiation Dose of Neonate Hospitalized in Intensive Care Units1561-41072251-7170https://doaj.org/article/edfc790f303d40218f180760051f44ae2020-03-01T00:00:00Zhttp://jbums.org/article-1-9122-en.htmlhttps://doaj.org/toc/1561-4107https://doaj.org/toc/2251-7170BACKGROUND AND OBJECTIVE: Newborns admitted to the neonatal intensive care unit (NICU) , would be undergo a large number of X-ray imaging due to their involvement with various diseases The most important complication of receiving too much X-rays is an increased risk of various cancers. The aim of this study was to determine the average cumulative dose received by neonates admitted to the neonatal intensive care unit. METHODS: This cross-sectional study was performed on 20 neonates admitted to the intensive care unit of Taleghani Children s Hospital who were randomly selected. Infant information registrated including time of birth, arrival time, duration of hospitalization, age, sex, weight and number of radiographs performed on the infant and radiographic information including tube-to-patient distance, tube voltage (kVp) and milliamperes (mAs). The amount of skin absorption dose of each patient was evaluated using MTS700 thermoluminescence dosimeter and the number of imaging was examined. FINDINGS: The amount of entrance skin dose of the studied neonates with an average of 78 micrograys varied from 42 to 121 micrograys (78±19.6). The mean number of imaging and cumulative dose were 6 (6±7.71) and 521 micrograys (521±547.99), respectively. The highest cumulative dose (2106 μg) was related to a neonate who underwent 27 imaging. CONCLUSION: According to the results of this study, the need for multiple imaging of these infants can significantly increase their absorption dose, especially in infants with very low weight.E EsmailiAR Khoshbin-KhoshnazarA JabbariZ Arab-BafraniBabol University of Medical Sciencesarticlediagnostic x-raynewbornentrance skin dosescumulative effective dose.MedicineRMedicine (General)R5-920ENFAMajallah-i Dānishgāh-i ̒Ulūm-i Pizishkī-i Bābul, Vol 22, Iss 1, Pp 253-258 (2020) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN FA |
topic |
diagnostic x-ray newborn entrance skin doses cumulative effective dose. Medicine R Medicine (General) R5-920 |
spellingShingle |
diagnostic x-ray newborn entrance skin doses cumulative effective dose. Medicine R Medicine (General) R5-920 E Esmaili AR Khoshbin-Khoshnazar A Jabbari Z Arab-Bafrani Assessment of Cumulative Radiation Dose of Neonate Hospitalized in Intensive Care Units |
description |
BACKGROUND AND OBJECTIVE: Newborns admitted to the neonatal intensive care unit (NICU) , would be undergo a large number of X-ray imaging due to their involvement with various diseases The most important complication of receiving too much X-rays is an increased risk of various cancers. The aim of this study was to determine the average cumulative dose received by neonates admitted to the neonatal intensive care unit.
METHODS: This cross-sectional study was performed on 20 neonates admitted to the intensive care unit of Taleghani Children s Hospital who were randomly selected. Infant information registrated including time of birth, arrival time, duration of hospitalization, age, sex, weight and number of radiographs performed on the infant and radiographic information including tube-to-patient distance, tube voltage (kVp) and milliamperes (mAs). The amount of skin absorption dose of each patient was evaluated using MTS700 thermoluminescence dosimeter and the number of imaging was examined.
FINDINGS: The amount of entrance skin dose of the studied neonates with an average of 78 micrograys varied from 42 to 121 micrograys (78±19.6). The mean number of imaging and cumulative dose were 6 (6±7.71) and 521 micrograys (521±547.99), respectively. The highest cumulative dose (2106 μg) was related to a neonate who underwent 27 imaging.
CONCLUSION: According to the results of this study, the need for multiple imaging of these infants can significantly increase their absorption dose, especially in infants with very low weight. |
format |
article |
author |
E Esmaili AR Khoshbin-Khoshnazar A Jabbari Z Arab-Bafrani |
author_facet |
E Esmaili AR Khoshbin-Khoshnazar A Jabbari Z Arab-Bafrani |
author_sort |
E Esmaili |
title |
Assessment of Cumulative Radiation Dose of Neonate Hospitalized in Intensive Care Units |
title_short |
Assessment of Cumulative Radiation Dose of Neonate Hospitalized in Intensive Care Units |
title_full |
Assessment of Cumulative Radiation Dose of Neonate Hospitalized in Intensive Care Units |
title_fullStr |
Assessment of Cumulative Radiation Dose of Neonate Hospitalized in Intensive Care Units |
title_full_unstemmed |
Assessment of Cumulative Radiation Dose of Neonate Hospitalized in Intensive Care Units |
title_sort |
assessment of cumulative radiation dose of neonate hospitalized in intensive care units |
publisher |
Babol University of Medical Sciences |
publishDate |
2020 |
url |
https://doaj.org/article/edfc790f303d40218f180760051f44ae |
work_keys_str_mv |
AT eesmaili assessmentofcumulativeradiationdoseofneonatehospitalizedinintensivecareunits AT arkhoshbinkhoshnazar assessmentofcumulativeradiationdoseofneonatehospitalizedinintensivecareunits AT ajabbari assessmentofcumulativeradiationdoseofneonatehospitalizedinintensivecareunits AT zarabbafrani assessmentofcumulativeradiationdoseofneonatehospitalizedinintensivecareunits |
_version_ |
1718441164048171008 |