Comparison of early F-18 Florbetaben PET/CT to Tc-99m ECD SPECT using voxel, regional, and network analysis

Abstract This study aimed to validate early-phase F-18 Florbetaben positron emission tomography (eFBB PET) as a brain perfusion test and determine the optimal reference region. A total of 27 patients with early Parkinson’s disease with Tc-99m ethyl cysteinate dimer single photon emission tomography...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Soo Jin Kwon, Seunggyun Ha, Sang-Won Yoo, Na-Young Shin, Joo Hyun O, Ie Ryung Yoo, Joong-Seok Kim
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/ee78872d95424fd1a6df9a8ab2386e02
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:ee78872d95424fd1a6df9a8ab2386e02
record_format dspace
spelling oai:doaj.org-article:ee78872d95424fd1a6df9a8ab2386e022021-12-02T15:10:39ZComparison of early F-18 Florbetaben PET/CT to Tc-99m ECD SPECT using voxel, regional, and network analysis10.1038/s41598-021-95808-82045-2322https://doaj.org/article/ee78872d95424fd1a6df9a8ab2386e022021-08-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-95808-8https://doaj.org/toc/2045-2322Abstract This study aimed to validate early-phase F-18 Florbetaben positron emission tomography (eFBB PET) as a brain perfusion test and determine the optimal reference region. A total of 27 patients with early Parkinson’s disease with Tc-99m ethyl cysteinate dimer single photon emission tomography (ECD SPECT) and FBB PET were included. Six reference regions, including whole brain (GN), pons, central white matter (CWM), whole cerebellum (WC), WC with brain stem (WC + B), and cerebellar grey matter (CG), were applied to obtain SUVR using cortex volume-of-interest (VOI). Reference regions of WC (r 0.886), WC + B (r 0.897), and CG (r 0.904) had highest correlation values of cortex-VOI SUVR between both perfusion images (all p < 0.001). Early-phase FBB PET had a significant linear correlation of CG-normalized SUVR of the cortex, basal ganglia, thalamus, and midbrain with ECD SPECT in voxel-wise analysis (FDR adjusted-p < 0.05). Early-phase FBB PET extracts more ICNS than ECD SPECT, as 9 ICNS and 4 ICNs, respectively. Both eFBB PET and ECD SPECT well discriminated PD from DLB (Area-under-curve of receiver-operating-characteristics, 0.911 for eFBB PET, 0.922 for ECD SPECT). Our findings suggest that eFBB PET is a reliable perfusion test based on a high correlation with ECD SPECT using cerebellum-based normalization methods.Soo Jin KwonSeunggyun HaSang-Won YooNa-Young ShinJoo Hyun OIe Ryung YooJoong-Seok KimNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-10 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Soo Jin Kwon
Seunggyun Ha
Sang-Won Yoo
Na-Young Shin
Joo Hyun O
Ie Ryung Yoo
Joong-Seok Kim
Comparison of early F-18 Florbetaben PET/CT to Tc-99m ECD SPECT using voxel, regional, and network analysis
description Abstract This study aimed to validate early-phase F-18 Florbetaben positron emission tomography (eFBB PET) as a brain perfusion test and determine the optimal reference region. A total of 27 patients with early Parkinson’s disease with Tc-99m ethyl cysteinate dimer single photon emission tomography (ECD SPECT) and FBB PET were included. Six reference regions, including whole brain (GN), pons, central white matter (CWM), whole cerebellum (WC), WC with brain stem (WC + B), and cerebellar grey matter (CG), were applied to obtain SUVR using cortex volume-of-interest (VOI). Reference regions of WC (r 0.886), WC + B (r 0.897), and CG (r 0.904) had highest correlation values of cortex-VOI SUVR between both perfusion images (all p < 0.001). Early-phase FBB PET had a significant linear correlation of CG-normalized SUVR of the cortex, basal ganglia, thalamus, and midbrain with ECD SPECT in voxel-wise analysis (FDR adjusted-p < 0.05). Early-phase FBB PET extracts more ICNS than ECD SPECT, as 9 ICNS and 4 ICNs, respectively. Both eFBB PET and ECD SPECT well discriminated PD from DLB (Area-under-curve of receiver-operating-characteristics, 0.911 for eFBB PET, 0.922 for ECD SPECT). Our findings suggest that eFBB PET is a reliable perfusion test based on a high correlation with ECD SPECT using cerebellum-based normalization methods.
format article
author Soo Jin Kwon
Seunggyun Ha
Sang-Won Yoo
Na-Young Shin
Joo Hyun O
Ie Ryung Yoo
Joong-Seok Kim
author_facet Soo Jin Kwon
Seunggyun Ha
Sang-Won Yoo
Na-Young Shin
Joo Hyun O
Ie Ryung Yoo
Joong-Seok Kim
author_sort Soo Jin Kwon
title Comparison of early F-18 Florbetaben PET/CT to Tc-99m ECD SPECT using voxel, regional, and network analysis
title_short Comparison of early F-18 Florbetaben PET/CT to Tc-99m ECD SPECT using voxel, regional, and network analysis
title_full Comparison of early F-18 Florbetaben PET/CT to Tc-99m ECD SPECT using voxel, regional, and network analysis
title_fullStr Comparison of early F-18 Florbetaben PET/CT to Tc-99m ECD SPECT using voxel, regional, and network analysis
title_full_unstemmed Comparison of early F-18 Florbetaben PET/CT to Tc-99m ECD SPECT using voxel, regional, and network analysis
title_sort comparison of early f-18 florbetaben pet/ct to tc-99m ecd spect using voxel, regional, and network analysis
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/ee78872d95424fd1a6df9a8ab2386e02
work_keys_str_mv AT soojinkwon comparisonofearlyf18florbetabenpetcttotc99mecdspectusingvoxelregionalandnetworkanalysis
AT seunggyunha comparisonofearlyf18florbetabenpetcttotc99mecdspectusingvoxelregionalandnetworkanalysis
AT sangwonyoo comparisonofearlyf18florbetabenpetcttotc99mecdspectusingvoxelregionalandnetworkanalysis
AT nayoungshin comparisonofearlyf18florbetabenpetcttotc99mecdspectusingvoxelregionalandnetworkanalysis
AT joohyuno comparisonofearlyf18florbetabenpetcttotc99mecdspectusingvoxelregionalandnetworkanalysis
AT ieryungyoo comparisonofearlyf18florbetabenpetcttotc99mecdspectusingvoxelregionalandnetworkanalysis
AT joongseokkim comparisonofearlyf18florbetabenpetcttotc99mecdspectusingvoxelregionalandnetworkanalysis
_version_ 1718387728376135680