Prospective randomized comparative study between venturi and peristaltic pumps in WhiteStar Signature® phacoemulsification machine

Wilson Takashi Hida,1–3 André Lins de Medeiros,1,2 André Gustavo de Araújo Rolim,1,2 Antonio Francisco Pimenta Motta,2,3 Danilo Varela Kniggendorf,1,2 Rodrigo Lafetá Franco de Queiroz,1,2 Mário Augusto Pereira Dias Chaves,1,2 Pedro Car...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Hida WT, de Medeiros AL, de Araujo Rolim AG, Motta AFP, Kniggendorf DV, de Queiroz RLF, Chaves MAPD, Carricondo PC, Nakano CT, Nosé W
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2018
Materias:
Acceso en línea:https://doaj.org/article/ef128e4f76c041d8b4d2d29dbab025b4
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:ef128e4f76c041d8b4d2d29dbab025b4
record_format dspace
spelling oai:doaj.org-article:ef128e4f76c041d8b4d2d29dbab025b42021-12-02T02:55:50ZProspective randomized comparative study between venturi and peristaltic pumps in WhiteStar Signature® phacoemulsification machine1177-5483https://doaj.org/article/ef128e4f76c041d8b4d2d29dbab025b42018-12-01T00:00:00Zhttps://www.dovepress.com/prospective-randomized-comparative-study-between-venturi-and-peristalt-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Wilson Takashi Hida,1–3 André Lins de Medeiros,1,2 André Gustavo de Araújo Rolim,1,2 Antonio Francisco Pimenta Motta,2,3 Danilo Varela Kniggendorf,1,2 Rodrigo Lafetá Franco de Queiroz,1,2 Mário Augusto Pereira Dias Chaves,1,2 Pedro Carlos Carricondo,1,2 Celso Takashi Nakano,2,4 Walton Nosé5 1Cataract Sector, Hospital Oftalmológico de Brasília, Brasília, Federal District, Brazil; 2Cataract Sector, Centro de Estudos Oftalmológicos Renato Ambrósio, Brasília, Brazil; 3Cataract Sector, Universidade de São Paulo, São Paulo, Brazil; 4Cataract Sector, Hospital Santa Cruz, São Paulo, Brazil; 5Cataract Sector, Universidade Federal de São Paulo, São Paulo, Brazil Purpose: To compare intraoperative parameters between venturi and peristaltic pump in WhiteStar Signature® phacoemulsification machine using the bevel-down technique.Setting: Hospital Oftalmológico de Brasília, Brasília, Federal District, Brazil.Design: Prospective, comparative, patient-masked study.Methods: Three hundred eyes were randomly assigned to have a phacoemulsification procedure with WhiteStar Signature® using either peristaltic (n=150 eyes) or venturi (n=150 eyes) pumps by a single surgeon (WTH). Elliptical ultrasound setting and prefracture (prechop or preslice) techniques were used in all cases. Cataract nucleus density was graded using lens opacities classification system III and Pentacam Nucleus Staging classification. Clinical measurements included preoperative- and postoperative- corrected visual acuity, preoperative and 2-month postoperative endothelial cell counts, and preoperative and 1-day postoperative central corneal thickness. Intraoperative measurements at the end of the case were phaco time, fluid used, total case time, and Efx energy.Results: There were no statistically significant differences between groups regarding age, cataract density, and phaco time (P>0.05). Intraoperatively, we observed significantly less ultrasound energy (P=0.011), case time (P=0.0001), and balanced saline solution (P=0.001) usage in the venturi group. Clinically, both fluidic settings can provide similar clinical outcomes and visual recovery, regarding corrected distance visual acuity, endothelial cell count, and central corneal thickness.Conclusion: Our data show that to minimize fluid use, case time, and energy with the prefracture technique, the venturi pump was the most efficient system and was statistically superior to peristaltic pump. Keywords: venturi, peristaltic, phacoemulsification, cataract surgery, vacuum efficiencyHida WTde Medeiros ALde Araujo Rolim AGMotta AFPKniggendorf DVde Queiroz RLFChaves MAPDCarricondo PCNakano CTNosé WDove Medical Pressarticleventuriperistalticphacoemulsificationcataract surgeryvacuum efficiencyOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 13, Pp 49-52 (2018)
institution DOAJ
collection DOAJ
language EN
topic venturi
peristaltic
phacoemulsification
cataract surgery
vacuum efficiency
Ophthalmology
RE1-994
spellingShingle venturi
peristaltic
phacoemulsification
cataract surgery
vacuum efficiency
Ophthalmology
RE1-994
Hida WT
de Medeiros AL
de Araujo Rolim AG
Motta AFP
Kniggendorf DV
de Queiroz RLF
Chaves MAPD
Carricondo PC
Nakano CT
Nosé W
Prospective randomized comparative study between venturi and peristaltic pumps in WhiteStar Signature® phacoemulsification machine
description Wilson Takashi Hida,1–3 André Lins de Medeiros,1,2 André Gustavo de Araújo Rolim,1,2 Antonio Francisco Pimenta Motta,2,3 Danilo Varela Kniggendorf,1,2 Rodrigo Lafetá Franco de Queiroz,1,2 Mário Augusto Pereira Dias Chaves,1,2 Pedro Carlos Carricondo,1,2 Celso Takashi Nakano,2,4 Walton Nosé5 1Cataract Sector, Hospital Oftalmológico de Brasília, Brasília, Federal District, Brazil; 2Cataract Sector, Centro de Estudos Oftalmológicos Renato Ambrósio, Brasília, Brazil; 3Cataract Sector, Universidade de São Paulo, São Paulo, Brazil; 4Cataract Sector, Hospital Santa Cruz, São Paulo, Brazil; 5Cataract Sector, Universidade Federal de São Paulo, São Paulo, Brazil Purpose: To compare intraoperative parameters between venturi and peristaltic pump in WhiteStar Signature® phacoemulsification machine using the bevel-down technique.Setting: Hospital Oftalmológico de Brasília, Brasília, Federal District, Brazil.Design: Prospective, comparative, patient-masked study.Methods: Three hundred eyes were randomly assigned to have a phacoemulsification procedure with WhiteStar Signature® using either peristaltic (n=150 eyes) or venturi (n=150 eyes) pumps by a single surgeon (WTH). Elliptical ultrasound setting and prefracture (prechop or preslice) techniques were used in all cases. Cataract nucleus density was graded using lens opacities classification system III and Pentacam Nucleus Staging classification. Clinical measurements included preoperative- and postoperative- corrected visual acuity, preoperative and 2-month postoperative endothelial cell counts, and preoperative and 1-day postoperative central corneal thickness. Intraoperative measurements at the end of the case were phaco time, fluid used, total case time, and Efx energy.Results: There were no statistically significant differences between groups regarding age, cataract density, and phaco time (P>0.05). Intraoperatively, we observed significantly less ultrasound energy (P=0.011), case time (P=0.0001), and balanced saline solution (P=0.001) usage in the venturi group. Clinically, both fluidic settings can provide similar clinical outcomes and visual recovery, regarding corrected distance visual acuity, endothelial cell count, and central corneal thickness.Conclusion: Our data show that to minimize fluid use, case time, and energy with the prefracture technique, the venturi pump was the most efficient system and was statistically superior to peristaltic pump. Keywords: venturi, peristaltic, phacoemulsification, cataract surgery, vacuum efficiency
format article
author Hida WT
de Medeiros AL
de Araujo Rolim AG
Motta AFP
Kniggendorf DV
de Queiroz RLF
Chaves MAPD
Carricondo PC
Nakano CT
Nosé W
author_facet Hida WT
de Medeiros AL
de Araujo Rolim AG
Motta AFP
Kniggendorf DV
de Queiroz RLF
Chaves MAPD
Carricondo PC
Nakano CT
Nosé W
author_sort Hida WT
title Prospective randomized comparative study between venturi and peristaltic pumps in WhiteStar Signature® phacoemulsification machine
title_short Prospective randomized comparative study between venturi and peristaltic pumps in WhiteStar Signature® phacoemulsification machine
title_full Prospective randomized comparative study between venturi and peristaltic pumps in WhiteStar Signature® phacoemulsification machine
title_fullStr Prospective randomized comparative study between venturi and peristaltic pumps in WhiteStar Signature® phacoemulsification machine
title_full_unstemmed Prospective randomized comparative study between venturi and peristaltic pumps in WhiteStar Signature® phacoemulsification machine
title_sort prospective randomized comparative study between venturi and peristaltic pumps in whitestar signature® phacoemulsification machine
publisher Dove Medical Press
publishDate 2018
url https://doaj.org/article/ef128e4f76c041d8b4d2d29dbab025b4
work_keys_str_mv AT hidawt prospectiverandomizedcomparativestudybetweenventuriandperistalticpumpsinwhitestarsignatureregphacoemulsificationmachine
AT demedeirosal prospectiverandomizedcomparativestudybetweenventuriandperistalticpumpsinwhitestarsignatureregphacoemulsificationmachine
AT dearaujorolimag prospectiverandomizedcomparativestudybetweenventuriandperistalticpumpsinwhitestarsignatureregphacoemulsificationmachine
AT mottaafp prospectiverandomizedcomparativestudybetweenventuriandperistalticpumpsinwhitestarsignatureregphacoemulsificationmachine
AT kniggendorfdv prospectiverandomizedcomparativestudybetweenventuriandperistalticpumpsinwhitestarsignatureregphacoemulsificationmachine
AT dequeirozrlf prospectiverandomizedcomparativestudybetweenventuriandperistalticpumpsinwhitestarsignatureregphacoemulsificationmachine
AT chavesmapd prospectiverandomizedcomparativestudybetweenventuriandperistalticpumpsinwhitestarsignatureregphacoemulsificationmachine
AT carricondopc prospectiverandomizedcomparativestudybetweenventuriandperistalticpumpsinwhitestarsignatureregphacoemulsificationmachine
AT nakanoct prospectiverandomizedcomparativestudybetweenventuriandperistalticpumpsinwhitestarsignatureregphacoemulsificationmachine
AT nosew prospectiverandomizedcomparativestudybetweenventuriandperistalticpumpsinwhitestarsignatureregphacoemulsificationmachine
_version_ 1718402077491724288