Design and Analysis of New Prosthetic Foot.

There is a variety of artificial foot designs variable for use with prosthetic legs . Most of the design can be divided into two classes, articulated and non-articulated feet. one common non-articulated foot is the SACH . The solid ankle cushion heel foot referred to as the SACH foot has a rigid kee...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Kadhim K.Al-Kinani,MSc, Ahamed A. Al-Beiruti ,PhD, Muhsin J. Jweeg, PhD
Formato: article
Lenguaje:EN
Publicado: Al-Khwarizmi College of Engineering – University of Baghdad 2007
Materias:
Acceso en línea:https://doaj.org/article/f005846d880d474f8f68f2576a2500b2
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:f005846d880d474f8f68f2576a2500b2
record_format dspace
spelling oai:doaj.org-article:f005846d880d474f8f68f2576a2500b22021-12-02T03:18:05ZDesign and Analysis of New Prosthetic Foot.1818-1171https://doaj.org/article/f005846d880d474f8f68f2576a2500b22007-01-01T00:00:00Zhttp://www.iasj.net/iasj?func=fulltext&aId=2248https://doaj.org/toc/1818-1171There is a variety of artificial foot designs variable for use with prosthetic legs . Most of the design can be divided into two classes, articulated and non-articulated feet. one common non-articulated foot is the SACH . The solid ankle cushion heel foot referred to as the SACH foot has a rigid keelOne key or the key factor in designing a new prosthesis is in the analysis of a patients response This view is the most important because if the foot does not provide functional , practical or cosmetically acceptable characteristics the patient will not feel comfortable with the prosthesis , therefore design and manufacturing a new foot is essential, this foot made from polyethylene, its different shape and characteristics The characteristics deemed important by patients in achieving natural gait motion include:<br /><br />Dorsiflexion <br />Energy return <br />Fatigue test In this study, including all these characteristics test, design fatigue foot tester according to ISO 10328 and design new foot .Also, the testometric crosshead was modified to find dorsiflexion angle and energy return .The fatigue criteria for polymer was proposed, in mathematical solution. Finally , the characteristics of SACH foot was compared with new foot by mathematical solution and used visual basic program and experimental method by different tests. From these test that the new foot is better than SACH foot for all test .Kadhim K.Al-Kinani,MScAhamed A. Al-Beiruti ,PhDMuhsin J. Jweeg, PhDAl-Khwarizmi College of Engineering – University of BaghdadarticleProsthetics footFatigueDorsiflexion ,Energy return and SACH foot .Chemical engineeringTP155-156Engineering (General). Civil engineering (General)TA1-2040ENAl-Khawarizmi Engineering Journal, Vol 3, Iss 1, Pp 12-25 (2007)
institution DOAJ
collection DOAJ
language EN
topic Prosthetics foot
Fatigue
Dorsiflexion ,Energy return and SACH foot .
Chemical engineering
TP155-156
Engineering (General). Civil engineering (General)
TA1-2040
spellingShingle Prosthetics foot
Fatigue
Dorsiflexion ,Energy return and SACH foot .
Chemical engineering
TP155-156
Engineering (General). Civil engineering (General)
TA1-2040
Kadhim K.Al-Kinani,MSc
Ahamed A. Al-Beiruti ,PhD
Muhsin J. Jweeg, PhD
Design and Analysis of New Prosthetic Foot.
description There is a variety of artificial foot designs variable for use with prosthetic legs . Most of the design can be divided into two classes, articulated and non-articulated feet. one common non-articulated foot is the SACH . The solid ankle cushion heel foot referred to as the SACH foot has a rigid keelOne key or the key factor in designing a new prosthesis is in the analysis of a patients response This view is the most important because if the foot does not provide functional , practical or cosmetically acceptable characteristics the patient will not feel comfortable with the prosthesis , therefore design and manufacturing a new foot is essential, this foot made from polyethylene, its different shape and characteristics The characteristics deemed important by patients in achieving natural gait motion include:<br /><br />Dorsiflexion <br />Energy return <br />Fatigue test In this study, including all these characteristics test, design fatigue foot tester according to ISO 10328 and design new foot .Also, the testometric crosshead was modified to find dorsiflexion angle and energy return .The fatigue criteria for polymer was proposed, in mathematical solution. Finally , the characteristics of SACH foot was compared with new foot by mathematical solution and used visual basic program and experimental method by different tests. From these test that the new foot is better than SACH foot for all test .
format article
author Kadhim K.Al-Kinani,MSc
Ahamed A. Al-Beiruti ,PhD
Muhsin J. Jweeg, PhD
author_facet Kadhim K.Al-Kinani,MSc
Ahamed A. Al-Beiruti ,PhD
Muhsin J. Jweeg, PhD
author_sort Kadhim K.Al-Kinani,MSc
title Design and Analysis of New Prosthetic Foot.
title_short Design and Analysis of New Prosthetic Foot.
title_full Design and Analysis of New Prosthetic Foot.
title_fullStr Design and Analysis of New Prosthetic Foot.
title_full_unstemmed Design and Analysis of New Prosthetic Foot.
title_sort design and analysis of new prosthetic foot.
publisher Al-Khwarizmi College of Engineering – University of Baghdad
publishDate 2007
url https://doaj.org/article/f005846d880d474f8f68f2576a2500b2
work_keys_str_mv AT kadhimkalkinanimsc designandanalysisofnewprostheticfoot
AT ahamedaalbeirutiphd designandanalysisofnewprostheticfoot
AT muhsinjjweegphd designandanalysisofnewprostheticfoot
_version_ 1718401831196950528