Seismic performance of high rise hybrid structures with moment frame configuration
The seismic design methods should pay special attention to the characteristics of ground motions especially in near fault. Near-field records are generally recognized by the sudden impulsive ground displacements in a short time domain in which contain large amount of kinetic energy. An important con...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | article |
Lenguaje: | FA |
Publicado: |
Iranian Society of Structrual Engineering (ISSE)
2017
|
Materias: | |
Acceso en línea: | https://doaj.org/article/f06b28989e99407896aebc573c96d687 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:f06b28989e99407896aebc573c96d687 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:f06b28989e99407896aebc573c96d6872021-11-08T15:47:38ZSeismic performance of high rise hybrid structures with moment frame configuration2476-39772538-261610.22065/jsce.2017.87042.1208https://doaj.org/article/f06b28989e99407896aebc573c96d6872017-07-01T00:00:00Zhttps://www.jsce.ir/article_47356_a5d20494fc5270c4f31e70fc269f113a.pdfhttps://doaj.org/toc/2476-3977https://doaj.org/toc/2538-2616The seismic design methods should pay special attention to the characteristics of ground motions especially in near fault. Near-field records are generally recognized by the sudden impulsive ground displacements in a short time domain in which contain large amount of kinetic energy. An important consequence of lateral displacement and story drift is the structural and non-structural damage. Many previous studies suggest that the mentioned parameters are sufficient to indicate the correlation between characteristics of the structural response and seismic risk. Framed tube system is one way to limit the movement of stories in high rise buildings. This structural system causes a similar behaviour of the whole resistant skeleton to a hollow tube, so that a significant increase is observed in lateral stiffness of the structure. In this study, the studied models are in the form of 20-story structures that are regular in plan and height. The resistant skeleton of the studied structures is designed according to the fourth edition of Standard No. 2800 as well as topics of the Iranian national building code. Based on the results obtained by conducting the nonlinear dynamic analyses, this study deals with the trend of variations in the target seismic response parameters subjected to the site-specific design spectrum according to the design provisions denoted in the Standard No. 2800. Topics and issues evaluated in this study include the lateral displacement, story drift and effect of the configuration of internal rigid frames in variation rates of the mentioned parameters. Based on the results, the maximum drift usually happened in the middle third of the structure height. Yet, the maximum response parameters of displacement and story drift were individually exposed to relative reduction and increase, regarding to replacement of the resistant skeleton from frame-tube into bundled-tube structure.Saman KhaliliAfshin Meshkat-DiniJ. Keyvani GhamsariIranian Society of Structrual Engineering (ISSE)articleframe tubebundled tubethree-component recorddisplacementdriftnonlinear dynamic responseBridge engineeringTG1-470Building constructionTH1-9745FAJournal of Structural and Construction Engineering, Vol 4, Iss شماره ویژه 1, Pp 88-97 (2017) |
institution |
DOAJ |
collection |
DOAJ |
language |
FA |
topic |
frame tube bundled tube three-component record displacement drift nonlinear dynamic response Bridge engineering TG1-470 Building construction TH1-9745 |
spellingShingle |
frame tube bundled tube three-component record displacement drift nonlinear dynamic response Bridge engineering TG1-470 Building construction TH1-9745 Saman Khalili Afshin Meshkat-Dini J. Keyvani Ghamsari Seismic performance of high rise hybrid structures with moment frame configuration |
description |
The seismic design methods should pay special attention to the characteristics of ground motions especially in near fault. Near-field records are generally recognized by the sudden impulsive ground displacements in a short time domain in which contain large amount of kinetic energy. An important consequence of lateral displacement and story drift is the structural and non-structural damage. Many previous studies suggest that the mentioned parameters are sufficient to indicate the correlation between characteristics of the structural response and seismic risk. Framed tube system is one way to limit the movement of stories in high rise buildings. This structural system causes a similar behaviour of the whole resistant skeleton to a hollow tube, so that a significant increase is observed in lateral stiffness of the structure. In this study, the studied models are in the form of 20-story structures that are regular in plan and height. The resistant skeleton of the studied structures is designed according to the fourth edition of Standard No. 2800 as well as topics of the Iranian national building code. Based on the results obtained by conducting the nonlinear dynamic analyses, this study deals with the trend of variations in the target seismic response parameters subjected to the site-specific design spectrum according to the design provisions denoted in the Standard No. 2800. Topics and issues evaluated in this study include the lateral displacement, story drift and effect of the configuration of internal rigid frames in variation rates of the mentioned parameters. Based on the results, the maximum drift usually happened in the middle third of the structure height. Yet, the maximum response parameters of displacement and story drift were individually exposed to relative reduction and increase, regarding to replacement of the resistant skeleton from frame-tube into bundled-tube structure. |
format |
article |
author |
Saman Khalili Afshin Meshkat-Dini J. Keyvani Ghamsari |
author_facet |
Saman Khalili Afshin Meshkat-Dini J. Keyvani Ghamsari |
author_sort |
Saman Khalili |
title |
Seismic performance of high rise hybrid structures with moment frame configuration |
title_short |
Seismic performance of high rise hybrid structures with moment frame configuration |
title_full |
Seismic performance of high rise hybrid structures with moment frame configuration |
title_fullStr |
Seismic performance of high rise hybrid structures with moment frame configuration |
title_full_unstemmed |
Seismic performance of high rise hybrid structures with moment frame configuration |
title_sort |
seismic performance of high rise hybrid structures with moment frame configuration |
publisher |
Iranian Society of Structrual Engineering (ISSE) |
publishDate |
2017 |
url |
https://doaj.org/article/f06b28989e99407896aebc573c96d687 |
work_keys_str_mv |
AT samankhalili seismicperformanceofhighrisehybridstructureswithmomentframeconfiguration AT afshinmeshkatdini seismicperformanceofhighrisehybridstructureswithmomentframeconfiguration AT jkeyvanighamsari seismicperformanceofhighrisehybridstructureswithmomentframeconfiguration |
_version_ |
1718441712797351936 |