Real-time intravascular photoacoustic-ultrasound imaging of lipid-laden plaque in human coronary artery at 16 frames per second
Abstract Intravascular photoacoustic-ultrasound (IVPA-US) imaging is an emerging hybrid modality for the detection of lipid-laden plaques, as it provides simultaneous morphological and lipid-specific chemical information of an artery wall. Real-time imaging and display at video-rate speed are critic...
Guardado en:
Autores principales: | , , , , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Nature Portfolio
2017
|
Materias: | |
Acceso en línea: | https://doaj.org/article/f0a4c44f479d46f7977a6afcb54e40c2 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:f0a4c44f479d46f7977a6afcb54e40c2 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:f0a4c44f479d46f7977a6afcb54e40c22021-12-02T12:32:36ZReal-time intravascular photoacoustic-ultrasound imaging of lipid-laden plaque in human coronary artery at 16 frames per second10.1038/s41598-017-01649-92045-2322https://doaj.org/article/f0a4c44f479d46f7977a6afcb54e40c22017-05-01T00:00:00Zhttps://doi.org/10.1038/s41598-017-01649-9https://doaj.org/toc/2045-2322Abstract Intravascular photoacoustic-ultrasound (IVPA-US) imaging is an emerging hybrid modality for the detection of lipid-laden plaques, as it provides simultaneous morphological and lipid-specific chemical information of an artery wall. Real-time imaging and display at video-rate speed are critical for clinical utility of the IVPA-US imaging technology. Here, we demonstrate a portable IVPA-US system capable of imaging at up to 25 frames per second in real-time display mode. This unprecedented imaging speed was achieved by concurrent innovations in excitation laser source, rotary joint assembly, 1 mm IVPA-US catheter size, differentiated A-line strategy, and real-time image processing and display algorithms. Spatial resolution, chemical specificity, and capability for imaging highly dynamic objects were evaluated by phantoms to characterize system performance. An imaging speed of 16 frames per second was determined to be adequate to suppress motion artifacts from cardiac pulsation for in vivo applications. The translational capability of this system for the detection of lipid-laden plaques was validated by ex vivo imaging of an atherosclerotic human coronary artery at 16 frames per second, which showed strong correlation to gold-standard histopathology. Thus, this high-speed IVPA-US imaging system presents significant advances in the translational intravascular and other endoscopic applications.Jie HuiYingchun CaoYi ZhangAyeeshik KolePu WangGuangli YuGregory EakinsMichael SturekWeibiao ChenJi-Xin ChengNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 7, Iss 1, Pp 1-11 (2017) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine R Science Q |
spellingShingle |
Medicine R Science Q Jie Hui Yingchun Cao Yi Zhang Ayeeshik Kole Pu Wang Guangli Yu Gregory Eakins Michael Sturek Weibiao Chen Ji-Xin Cheng Real-time intravascular photoacoustic-ultrasound imaging of lipid-laden plaque in human coronary artery at 16 frames per second |
description |
Abstract Intravascular photoacoustic-ultrasound (IVPA-US) imaging is an emerging hybrid modality for the detection of lipid-laden plaques, as it provides simultaneous morphological and lipid-specific chemical information of an artery wall. Real-time imaging and display at video-rate speed are critical for clinical utility of the IVPA-US imaging technology. Here, we demonstrate a portable IVPA-US system capable of imaging at up to 25 frames per second in real-time display mode. This unprecedented imaging speed was achieved by concurrent innovations in excitation laser source, rotary joint assembly, 1 mm IVPA-US catheter size, differentiated A-line strategy, and real-time image processing and display algorithms. Spatial resolution, chemical specificity, and capability for imaging highly dynamic objects were evaluated by phantoms to characterize system performance. An imaging speed of 16 frames per second was determined to be adequate to suppress motion artifacts from cardiac pulsation for in vivo applications. The translational capability of this system for the detection of lipid-laden plaques was validated by ex vivo imaging of an atherosclerotic human coronary artery at 16 frames per second, which showed strong correlation to gold-standard histopathology. Thus, this high-speed IVPA-US imaging system presents significant advances in the translational intravascular and other endoscopic applications. |
format |
article |
author |
Jie Hui Yingchun Cao Yi Zhang Ayeeshik Kole Pu Wang Guangli Yu Gregory Eakins Michael Sturek Weibiao Chen Ji-Xin Cheng |
author_facet |
Jie Hui Yingchun Cao Yi Zhang Ayeeshik Kole Pu Wang Guangli Yu Gregory Eakins Michael Sturek Weibiao Chen Ji-Xin Cheng |
author_sort |
Jie Hui |
title |
Real-time intravascular photoacoustic-ultrasound imaging of lipid-laden plaque in human coronary artery at 16 frames per second |
title_short |
Real-time intravascular photoacoustic-ultrasound imaging of lipid-laden plaque in human coronary artery at 16 frames per second |
title_full |
Real-time intravascular photoacoustic-ultrasound imaging of lipid-laden plaque in human coronary artery at 16 frames per second |
title_fullStr |
Real-time intravascular photoacoustic-ultrasound imaging of lipid-laden plaque in human coronary artery at 16 frames per second |
title_full_unstemmed |
Real-time intravascular photoacoustic-ultrasound imaging of lipid-laden plaque in human coronary artery at 16 frames per second |
title_sort |
real-time intravascular photoacoustic-ultrasound imaging of lipid-laden plaque in human coronary artery at 16 frames per second |
publisher |
Nature Portfolio |
publishDate |
2017 |
url |
https://doaj.org/article/f0a4c44f479d46f7977a6afcb54e40c2 |
work_keys_str_mv |
AT jiehui realtimeintravascularphotoacousticultrasoundimagingoflipidladenplaqueinhumancoronaryarteryat16framespersecond AT yingchuncao realtimeintravascularphotoacousticultrasoundimagingoflipidladenplaqueinhumancoronaryarteryat16framespersecond AT yizhang realtimeintravascularphotoacousticultrasoundimagingoflipidladenplaqueinhumancoronaryarteryat16framespersecond AT ayeeshikkole realtimeintravascularphotoacousticultrasoundimagingoflipidladenplaqueinhumancoronaryarteryat16framespersecond AT puwang realtimeintravascularphotoacousticultrasoundimagingoflipidladenplaqueinhumancoronaryarteryat16framespersecond AT guangliyu realtimeintravascularphotoacousticultrasoundimagingoflipidladenplaqueinhumancoronaryarteryat16framespersecond AT gregoryeakins realtimeintravascularphotoacousticultrasoundimagingoflipidladenplaqueinhumancoronaryarteryat16framespersecond AT michaelsturek realtimeintravascularphotoacousticultrasoundimagingoflipidladenplaqueinhumancoronaryarteryat16framespersecond AT weibiaochen realtimeintravascularphotoacousticultrasoundimagingoflipidladenplaqueinhumancoronaryarteryat16framespersecond AT jixincheng realtimeintravascularphotoacousticultrasoundimagingoflipidladenplaqueinhumancoronaryarteryat16framespersecond |
_version_ |
1718394072148738048 |