GIS-BASED THERMAL LOAD ESTIMATION OF BUILDINGS IN THE NATIONAL SCIENCE COMPLEX, UP DILIMAN

Building thermal load is the energy exhausted to maintain a specific indoor temperature in comparison to the outdoor temperature. Majority of this energy makes use of a considerable amount of fossil fuels which contributes to greenhouse gases emission leading to global warming. Thermal load estimati...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: C. A. Tatlonghari, J. A. Principe
Formato: article
Lenguaje:EN
Publicado: Copernicus Publications 2021
Materias:
T
Acceso en línea:https://doaj.org/article/f0d5bc36b33b4882b7b2e30bdcedecb6
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:f0d5bc36b33b4882b7b2e30bdcedecb6
record_format dspace
spelling oai:doaj.org-article:f0d5bc36b33b4882b7b2e30bdcedecb62021-11-19T01:51:14ZGIS-BASED THERMAL LOAD ESTIMATION OF BUILDINGS IN THE NATIONAL SCIENCE COMPLEX, UP DILIMAN10.5194/isprs-archives-XLVI-4-W6-2021-289-20211682-17502194-9034https://doaj.org/article/f0d5bc36b33b4882b7b2e30bdcedecb62021-11-01T00:00:00Zhttps://www.int-arch-photogramm-remote-sens-spatial-inf-sci.net/XLVI-4-W6-2021/289/2021/isprs-archives-XLVI-4-W6-2021-289-2021.pdfhttps://doaj.org/toc/1682-1750https://doaj.org/toc/2194-9034Building thermal load is the energy exhausted to maintain a specific indoor temperature in comparison to the outdoor temperature. Majority of this energy makes use of a considerable amount of fossil fuels which contributes to greenhouse gases emission leading to global warming. Thermal load estimation of buildings allows people to identify infrastructures in need for retrofit for a more sustainable and smart urban management. This paper presents a small-scale study to estimate the thermal cooling load of fourteen (14) buildings in the National Science Complex of the University of the Philippines Diliman. Results of the annual cooling load calculation for the year 2020 was reported with an estimated lowest cooling load of 1,618 kW for the Philippine Atmospheric, Geophysical and Astronomical Services Administration (PAGASA) observatory and the highest cooling load of 13,484 kW for the Institute of Mathematics. The values calculated was an overestimation as the entire building was set up as a homogenous cold room without any windows or doors. For future work, it is recommended that input data be supplemented with digital surface model (DSM) and triangulated irregular network (TIN) raster data derived from Light Detection and Ranging (LiDAR) to not only categorize but assign specific values over each building group of the study area.C. A. TatlonghariJ. A. PrincipeCopernicus PublicationsarticleTechnologyTEngineering (General). Civil engineering (General)TA1-2040Applied optics. PhotonicsTA1501-1820ENThe International Archives of the Photogrammetry, Remote Sensing and Spatial Information Sciences, Vol XLVI-4-W6-2021, Pp 289-294 (2021)
institution DOAJ
collection DOAJ
language EN
topic Technology
T
Engineering (General). Civil engineering (General)
TA1-2040
Applied optics. Photonics
TA1501-1820
spellingShingle Technology
T
Engineering (General). Civil engineering (General)
TA1-2040
Applied optics. Photonics
TA1501-1820
C. A. Tatlonghari
J. A. Principe
GIS-BASED THERMAL LOAD ESTIMATION OF BUILDINGS IN THE NATIONAL SCIENCE COMPLEX, UP DILIMAN
description Building thermal load is the energy exhausted to maintain a specific indoor temperature in comparison to the outdoor temperature. Majority of this energy makes use of a considerable amount of fossil fuels which contributes to greenhouse gases emission leading to global warming. Thermal load estimation of buildings allows people to identify infrastructures in need for retrofit for a more sustainable and smart urban management. This paper presents a small-scale study to estimate the thermal cooling load of fourteen (14) buildings in the National Science Complex of the University of the Philippines Diliman. Results of the annual cooling load calculation for the year 2020 was reported with an estimated lowest cooling load of 1,618 kW for the Philippine Atmospheric, Geophysical and Astronomical Services Administration (PAGASA) observatory and the highest cooling load of 13,484 kW for the Institute of Mathematics. The values calculated was an overestimation as the entire building was set up as a homogenous cold room without any windows or doors. For future work, it is recommended that input data be supplemented with digital surface model (DSM) and triangulated irregular network (TIN) raster data derived from Light Detection and Ranging (LiDAR) to not only categorize but assign specific values over each building group of the study area.
format article
author C. A. Tatlonghari
J. A. Principe
author_facet C. A. Tatlonghari
J. A. Principe
author_sort C. A. Tatlonghari
title GIS-BASED THERMAL LOAD ESTIMATION OF BUILDINGS IN THE NATIONAL SCIENCE COMPLEX, UP DILIMAN
title_short GIS-BASED THERMAL LOAD ESTIMATION OF BUILDINGS IN THE NATIONAL SCIENCE COMPLEX, UP DILIMAN
title_full GIS-BASED THERMAL LOAD ESTIMATION OF BUILDINGS IN THE NATIONAL SCIENCE COMPLEX, UP DILIMAN
title_fullStr GIS-BASED THERMAL LOAD ESTIMATION OF BUILDINGS IN THE NATIONAL SCIENCE COMPLEX, UP DILIMAN
title_full_unstemmed GIS-BASED THERMAL LOAD ESTIMATION OF BUILDINGS IN THE NATIONAL SCIENCE COMPLEX, UP DILIMAN
title_sort gis-based thermal load estimation of buildings in the national science complex, up diliman
publisher Copernicus Publications
publishDate 2021
url https://doaj.org/article/f0d5bc36b33b4882b7b2e30bdcedecb6
work_keys_str_mv AT catatlonghari gisbasedthermalloadestimationofbuildingsinthenationalsciencecomplexupdiliman
AT japrincipe gisbasedthermalloadestimationofbuildingsinthenationalsciencecomplexupdiliman
_version_ 1718420643999907840