Wide-field fluorescent nanodiamond spin measurements toward real-time large-area intracellular thermometry

Abstract Measuring optically detected magnetic resonance (ODMR) of diamond nitrogen vacancy centers significantly depends on the photon detectors used. We study camera-based wide-field ODMR measurements to examine the performance in thermometry by comparing the results to those of the confocal-based...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Yushi Nishimura, Keisuke Oshimi, Yumi Umehara, Yuka Kumon, Kazu Miyaji, Hiroshi Yukawa, Yutaka Shikano, Tsutomu Matsubara, Masazumi Fujiwara, Yoshinobu Baba, Yoshio Teki
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/f0f59cf4b73b43128d3fd385a7a7e7ec
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:f0f59cf4b73b43128d3fd385a7a7e7ec
record_format dspace
spelling oai:doaj.org-article:f0f59cf4b73b43128d3fd385a7a7e7ec2021-12-02T12:11:35ZWide-field fluorescent nanodiamond spin measurements toward real-time large-area intracellular thermometry10.1038/s41598-021-83285-y2045-2322https://doaj.org/article/f0f59cf4b73b43128d3fd385a7a7e7ec2021-02-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-83285-yhttps://doaj.org/toc/2045-2322Abstract Measuring optically detected magnetic resonance (ODMR) of diamond nitrogen vacancy centers significantly depends on the photon detectors used. We study camera-based wide-field ODMR measurements to examine the performance in thermometry by comparing the results to those of the confocal-based ODMR detection. We show that the temperature sensitivity of the camera-based measurements can be as high as that of the confocal detection and that possible artifacts of the ODMR shift are produced owing to the complexity of the camera-based measurements. Although measurements from wide-field ODMR of nanodiamonds in living cells can provide temperature precisions consistent with those of confocal detection, the technique requires the integration of rapid ODMR measurement protocols for better precisions. Our results can aid the development of camera-based real-time large-area spin-based thermometry of living cells.Yushi NishimuraKeisuke OshimiYumi UmeharaYuka KumonKazu MiyajiHiroshi YukawaYutaka ShikanoTsutomu MatsubaraMasazumi FujiwaraYoshinobu BabaYoshio TekiNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-12 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Yushi Nishimura
Keisuke Oshimi
Yumi Umehara
Yuka Kumon
Kazu Miyaji
Hiroshi Yukawa
Yutaka Shikano
Tsutomu Matsubara
Masazumi Fujiwara
Yoshinobu Baba
Yoshio Teki
Wide-field fluorescent nanodiamond spin measurements toward real-time large-area intracellular thermometry
description Abstract Measuring optically detected magnetic resonance (ODMR) of diamond nitrogen vacancy centers significantly depends on the photon detectors used. We study camera-based wide-field ODMR measurements to examine the performance in thermometry by comparing the results to those of the confocal-based ODMR detection. We show that the temperature sensitivity of the camera-based measurements can be as high as that of the confocal detection and that possible artifacts of the ODMR shift are produced owing to the complexity of the camera-based measurements. Although measurements from wide-field ODMR of nanodiamonds in living cells can provide temperature precisions consistent with those of confocal detection, the technique requires the integration of rapid ODMR measurement protocols for better precisions. Our results can aid the development of camera-based real-time large-area spin-based thermometry of living cells.
format article
author Yushi Nishimura
Keisuke Oshimi
Yumi Umehara
Yuka Kumon
Kazu Miyaji
Hiroshi Yukawa
Yutaka Shikano
Tsutomu Matsubara
Masazumi Fujiwara
Yoshinobu Baba
Yoshio Teki
author_facet Yushi Nishimura
Keisuke Oshimi
Yumi Umehara
Yuka Kumon
Kazu Miyaji
Hiroshi Yukawa
Yutaka Shikano
Tsutomu Matsubara
Masazumi Fujiwara
Yoshinobu Baba
Yoshio Teki
author_sort Yushi Nishimura
title Wide-field fluorescent nanodiamond spin measurements toward real-time large-area intracellular thermometry
title_short Wide-field fluorescent nanodiamond spin measurements toward real-time large-area intracellular thermometry
title_full Wide-field fluorescent nanodiamond spin measurements toward real-time large-area intracellular thermometry
title_fullStr Wide-field fluorescent nanodiamond spin measurements toward real-time large-area intracellular thermometry
title_full_unstemmed Wide-field fluorescent nanodiamond spin measurements toward real-time large-area intracellular thermometry
title_sort wide-field fluorescent nanodiamond spin measurements toward real-time large-area intracellular thermometry
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/f0f59cf4b73b43128d3fd385a7a7e7ec
work_keys_str_mv AT yushinishimura widefieldfluorescentnanodiamondspinmeasurementstowardrealtimelargeareaintracellularthermometry
AT keisukeoshimi widefieldfluorescentnanodiamondspinmeasurementstowardrealtimelargeareaintracellularthermometry
AT yumiumehara widefieldfluorescentnanodiamondspinmeasurementstowardrealtimelargeareaintracellularthermometry
AT yukakumon widefieldfluorescentnanodiamondspinmeasurementstowardrealtimelargeareaintracellularthermometry
AT kazumiyaji widefieldfluorescentnanodiamondspinmeasurementstowardrealtimelargeareaintracellularthermometry
AT hiroshiyukawa widefieldfluorescentnanodiamondspinmeasurementstowardrealtimelargeareaintracellularthermometry
AT yutakashikano widefieldfluorescentnanodiamondspinmeasurementstowardrealtimelargeareaintracellularthermometry
AT tsutomumatsubara widefieldfluorescentnanodiamondspinmeasurementstowardrealtimelargeareaintracellularthermometry
AT masazumifujiwara widefieldfluorescentnanodiamondspinmeasurementstowardrealtimelargeareaintracellularthermometry
AT yoshinobubaba widefieldfluorescentnanodiamondspinmeasurementstowardrealtimelargeareaintracellularthermometry
AT yoshioteki widefieldfluorescentnanodiamondspinmeasurementstowardrealtimelargeareaintracellularthermometry
_version_ 1718394665633316864