Wide-field fluorescent nanodiamond spin measurements toward real-time large-area intracellular thermometry
Abstract Measuring optically detected magnetic resonance (ODMR) of diamond nitrogen vacancy centers significantly depends on the photon detectors used. We study camera-based wide-field ODMR measurements to examine the performance in thermometry by comparing the results to those of the confocal-based...
Guardado en:
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Nature Portfolio
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/f0f59cf4b73b43128d3fd385a7a7e7ec |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:f0f59cf4b73b43128d3fd385a7a7e7ec |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:f0f59cf4b73b43128d3fd385a7a7e7ec2021-12-02T12:11:35ZWide-field fluorescent nanodiamond spin measurements toward real-time large-area intracellular thermometry10.1038/s41598-021-83285-y2045-2322https://doaj.org/article/f0f59cf4b73b43128d3fd385a7a7e7ec2021-02-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-83285-yhttps://doaj.org/toc/2045-2322Abstract Measuring optically detected magnetic resonance (ODMR) of diamond nitrogen vacancy centers significantly depends on the photon detectors used. We study camera-based wide-field ODMR measurements to examine the performance in thermometry by comparing the results to those of the confocal-based ODMR detection. We show that the temperature sensitivity of the camera-based measurements can be as high as that of the confocal detection and that possible artifacts of the ODMR shift are produced owing to the complexity of the camera-based measurements. Although measurements from wide-field ODMR of nanodiamonds in living cells can provide temperature precisions consistent with those of confocal detection, the technique requires the integration of rapid ODMR measurement protocols for better precisions. Our results can aid the development of camera-based real-time large-area spin-based thermometry of living cells.Yushi NishimuraKeisuke OshimiYumi UmeharaYuka KumonKazu MiyajiHiroshi YukawaYutaka ShikanoTsutomu MatsubaraMasazumi FujiwaraYoshinobu BabaYoshio TekiNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-12 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine R Science Q |
spellingShingle |
Medicine R Science Q Yushi Nishimura Keisuke Oshimi Yumi Umehara Yuka Kumon Kazu Miyaji Hiroshi Yukawa Yutaka Shikano Tsutomu Matsubara Masazumi Fujiwara Yoshinobu Baba Yoshio Teki Wide-field fluorescent nanodiamond spin measurements toward real-time large-area intracellular thermometry |
description |
Abstract Measuring optically detected magnetic resonance (ODMR) of diamond nitrogen vacancy centers significantly depends on the photon detectors used. We study camera-based wide-field ODMR measurements to examine the performance in thermometry by comparing the results to those of the confocal-based ODMR detection. We show that the temperature sensitivity of the camera-based measurements can be as high as that of the confocal detection and that possible artifacts of the ODMR shift are produced owing to the complexity of the camera-based measurements. Although measurements from wide-field ODMR of nanodiamonds in living cells can provide temperature precisions consistent with those of confocal detection, the technique requires the integration of rapid ODMR measurement protocols for better precisions. Our results can aid the development of camera-based real-time large-area spin-based thermometry of living cells. |
format |
article |
author |
Yushi Nishimura Keisuke Oshimi Yumi Umehara Yuka Kumon Kazu Miyaji Hiroshi Yukawa Yutaka Shikano Tsutomu Matsubara Masazumi Fujiwara Yoshinobu Baba Yoshio Teki |
author_facet |
Yushi Nishimura Keisuke Oshimi Yumi Umehara Yuka Kumon Kazu Miyaji Hiroshi Yukawa Yutaka Shikano Tsutomu Matsubara Masazumi Fujiwara Yoshinobu Baba Yoshio Teki |
author_sort |
Yushi Nishimura |
title |
Wide-field fluorescent nanodiamond spin measurements toward real-time large-area intracellular thermometry |
title_short |
Wide-field fluorescent nanodiamond spin measurements toward real-time large-area intracellular thermometry |
title_full |
Wide-field fluorescent nanodiamond spin measurements toward real-time large-area intracellular thermometry |
title_fullStr |
Wide-field fluorescent nanodiamond spin measurements toward real-time large-area intracellular thermometry |
title_full_unstemmed |
Wide-field fluorescent nanodiamond spin measurements toward real-time large-area intracellular thermometry |
title_sort |
wide-field fluorescent nanodiamond spin measurements toward real-time large-area intracellular thermometry |
publisher |
Nature Portfolio |
publishDate |
2021 |
url |
https://doaj.org/article/f0f59cf4b73b43128d3fd385a7a7e7ec |
work_keys_str_mv |
AT yushinishimura widefieldfluorescentnanodiamondspinmeasurementstowardrealtimelargeareaintracellularthermometry AT keisukeoshimi widefieldfluorescentnanodiamondspinmeasurementstowardrealtimelargeareaintracellularthermometry AT yumiumehara widefieldfluorescentnanodiamondspinmeasurementstowardrealtimelargeareaintracellularthermometry AT yukakumon widefieldfluorescentnanodiamondspinmeasurementstowardrealtimelargeareaintracellularthermometry AT kazumiyaji widefieldfluorescentnanodiamondspinmeasurementstowardrealtimelargeareaintracellularthermometry AT hiroshiyukawa widefieldfluorescentnanodiamondspinmeasurementstowardrealtimelargeareaintracellularthermometry AT yutakashikano widefieldfluorescentnanodiamondspinmeasurementstowardrealtimelargeareaintracellularthermometry AT tsutomumatsubara widefieldfluorescentnanodiamondspinmeasurementstowardrealtimelargeareaintracellularthermometry AT masazumifujiwara widefieldfluorescentnanodiamondspinmeasurementstowardrealtimelargeareaintracellularthermometry AT yoshinobubaba widefieldfluorescentnanodiamondspinmeasurementstowardrealtimelargeareaintracellularthermometry AT yoshioteki widefieldfluorescentnanodiamondspinmeasurementstowardrealtimelargeareaintracellularthermometry |
_version_ |
1718394665633316864 |