Image quality is resilient against tube voltage variations in post-mortem skeletal radiography with a digital flat-panel detector

Abstract In recent phantom studies low-contrast detectability was shown to be independent from variations in tube voltage in digital radiography (DR) systems. To investigate the transferability to a clinical setting, the lower extremities of human cadavers were exposed at constant detector doses wit...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: S. Notohamiprodjo, K. M. Roeper, K. M. Treitl, B. Hoberg, F. Wanninger, L. Verstreepen, F. G. Mueck, D. Maxien, F. Fischer, O. Peschel, S. Wirth
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/f12d533cc7284e60943c38ec08cab3ec
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:f12d533cc7284e60943c38ec08cab3ec
record_format dspace
spelling oai:doaj.org-article:f12d533cc7284e60943c38ec08cab3ec2021-12-02T14:17:16ZImage quality is resilient against tube voltage variations in post-mortem skeletal radiography with a digital flat-panel detector10.1038/s41598-021-87294-92045-2322https://doaj.org/article/f12d533cc7284e60943c38ec08cab3ec2021-04-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-87294-9https://doaj.org/toc/2045-2322Abstract In recent phantom studies low-contrast detectability was shown to be independent from variations in tube voltage in digital radiography (DR) systems. To investigate the transferability to a clinical setting, the lower extremities of human cadavers were exposed at constant detector doses with different tube voltages in a certain range, as proposed in the phantom studies. Three radiologists independently graded different aspects of image quality (IQ) in a comparative analysis. The grades show no correlation between IQ and kV, which means that the readers were not able to recognize a significant IQ difference at different kV. Signal-to-noise and contrast-to-noise ratios showed no significant differences in IQ despite the kV-setting variations. These findings were observed from a limited kV range setting. Higher kV-settings resulted in lowest patient exposure at constant IQ. These results confirm the potential of DR-systems to contribute to standardization of examination protocols comparable to computed tomography. This may prevent the trend to overexpose. Further investigations in other body regions and other DR-systems are encouraged to determine transferability.S. NotohamiprodjoK. M. RoeperK. M. TreitlB. HobergF. WanningerL. VerstreepenF. G. MueckD. MaxienF. FischerO. PeschelS. WirthNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-12 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
S. Notohamiprodjo
K. M. Roeper
K. M. Treitl
B. Hoberg
F. Wanninger
L. Verstreepen
F. G. Mueck
D. Maxien
F. Fischer
O. Peschel
S. Wirth
Image quality is resilient against tube voltage variations in post-mortem skeletal radiography with a digital flat-panel detector
description Abstract In recent phantom studies low-contrast detectability was shown to be independent from variations in tube voltage in digital radiography (DR) systems. To investigate the transferability to a clinical setting, the lower extremities of human cadavers were exposed at constant detector doses with different tube voltages in a certain range, as proposed in the phantom studies. Three radiologists independently graded different aspects of image quality (IQ) in a comparative analysis. The grades show no correlation between IQ and kV, which means that the readers were not able to recognize a significant IQ difference at different kV. Signal-to-noise and contrast-to-noise ratios showed no significant differences in IQ despite the kV-setting variations. These findings were observed from a limited kV range setting. Higher kV-settings resulted in lowest patient exposure at constant IQ. These results confirm the potential of DR-systems to contribute to standardization of examination protocols comparable to computed tomography. This may prevent the trend to overexpose. Further investigations in other body regions and other DR-systems are encouraged to determine transferability.
format article
author S. Notohamiprodjo
K. M. Roeper
K. M. Treitl
B. Hoberg
F. Wanninger
L. Verstreepen
F. G. Mueck
D. Maxien
F. Fischer
O. Peschel
S. Wirth
author_facet S. Notohamiprodjo
K. M. Roeper
K. M. Treitl
B. Hoberg
F. Wanninger
L. Verstreepen
F. G. Mueck
D. Maxien
F. Fischer
O. Peschel
S. Wirth
author_sort S. Notohamiprodjo
title Image quality is resilient against tube voltage variations in post-mortem skeletal radiography with a digital flat-panel detector
title_short Image quality is resilient against tube voltage variations in post-mortem skeletal radiography with a digital flat-panel detector
title_full Image quality is resilient against tube voltage variations in post-mortem skeletal radiography with a digital flat-panel detector
title_fullStr Image quality is resilient against tube voltage variations in post-mortem skeletal radiography with a digital flat-panel detector
title_full_unstemmed Image quality is resilient against tube voltage variations in post-mortem skeletal radiography with a digital flat-panel detector
title_sort image quality is resilient against tube voltage variations in post-mortem skeletal radiography with a digital flat-panel detector
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/f12d533cc7284e60943c38ec08cab3ec
work_keys_str_mv AT snotohamiprodjo imagequalityisresilientagainsttubevoltagevariationsinpostmortemskeletalradiographywithadigitalflatpaneldetector
AT kmroeper imagequalityisresilientagainsttubevoltagevariationsinpostmortemskeletalradiographywithadigitalflatpaneldetector
AT kmtreitl imagequalityisresilientagainsttubevoltagevariationsinpostmortemskeletalradiographywithadigitalflatpaneldetector
AT bhoberg imagequalityisresilientagainsttubevoltagevariationsinpostmortemskeletalradiographywithadigitalflatpaneldetector
AT fwanninger imagequalityisresilientagainsttubevoltagevariationsinpostmortemskeletalradiographywithadigitalflatpaneldetector
AT lverstreepen imagequalityisresilientagainsttubevoltagevariationsinpostmortemskeletalradiographywithadigitalflatpaneldetector
AT fgmueck imagequalityisresilientagainsttubevoltagevariationsinpostmortemskeletalradiographywithadigitalflatpaneldetector
AT dmaxien imagequalityisresilientagainsttubevoltagevariationsinpostmortemskeletalradiographywithadigitalflatpaneldetector
AT ffischer imagequalityisresilientagainsttubevoltagevariationsinpostmortemskeletalradiographywithadigitalflatpaneldetector
AT opeschel imagequalityisresilientagainsttubevoltagevariationsinpostmortemskeletalradiographywithadigitalflatpaneldetector
AT swirth imagequalityisresilientagainsttubevoltagevariationsinpostmortemskeletalradiographywithadigitalflatpaneldetector
_version_ 1718391640934055936