Extensive frontal focused ultrasound mediated blood–brain barrier opening for the treatment of Alzheimer’s disease: a proof-of-concept study

Abstract Background Focused ultrasound (FUS)-mediated blood–brain barrier (BBB) opening has shown efficacy in removal of amyloid plaque and improvement of cognitive functions in preclinical studies, but this is rarely reported in clinical studies. This study was conducted to evaluate the safety, fea...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: So Hee Park, Kyoungwon Baik, Seun Jeon, Won Seok Chang, Byoung Seok Ye, Jin Woo Chang
Formato: article
Lenguaje:EN
Publicado: BMC 2021
Materias:
Acceso en línea:https://doaj.org/article/f18ef97d94344d85a042423ae5670bea
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:f18ef97d94344d85a042423ae5670bea
record_format dspace
spelling oai:doaj.org-article:f18ef97d94344d85a042423ae5670bea2021-11-08T11:03:23ZExtensive frontal focused ultrasound mediated blood–brain barrier opening for the treatment of Alzheimer’s disease: a proof-of-concept study10.1186/s40035-021-00269-82047-9158https://doaj.org/article/f18ef97d94344d85a042423ae5670bea2021-11-01T00:00:00Zhttps://doi.org/10.1186/s40035-021-00269-8https://doaj.org/toc/2047-9158Abstract Background Focused ultrasound (FUS)-mediated blood–brain barrier (BBB) opening has shown efficacy in removal of amyloid plaque and improvement of cognitive functions in preclinical studies, but this is rarely reported in clinical studies. This study was conducted to evaluate the safety, feasibility and potential benefits of repeated extensive BBB opening. Methods In this open-label, prospective study, six patients with Alzheimer’s disease (AD) were enrolled at Severance Hospital in Korea between August 2020 and September 2020. Five of them completed the study. FUS-mediated BBB opening, targeting the bilateral frontal lobe regions over 20 cm3, was performed twice at three-month intervals. Magnetic resonance imaging, 18F-Florbetaben (FBB) positron emission tomography, Caregiver-Administered Neuropsychiatric Inventory (CGA-NPI) and comprehensive neuropsychological tests were performed before and after the procedures. Results FUS targeted a mean volume of 21.1 ± 2.7 cm3 and BBB opening was confirmed at 95.7% ± 9.4% of the targeted volume. The frontal-to-other cortical region FBB standardized uptake value ratio at 3 months after the procedure showed a slight decrease, which was statistically significant, compared to the pre-procedure value (− 1.6%, 0.986 vs1.002, P = 0.043). The CGA-NPI score at 2 weeks after the second procedure significantly decreased compared to baseline (2.2 ± 3.0 vs 8.6 ± 6.0, P = 0.042), but recovered after 3 months (5.2 ± 5.8 vs 8.6 ± 6.0, P = 0.89). No adverse effects were observed. Conclusions The repeated and extensive BBB opening in the frontal lobe is safe and feasible for patients with AD. In addition, the BBB opening is potentially beneficial for amyloid removal in AD patients.So Hee ParkKyoungwon BaikSeun JeonWon Seok ChangByoung Seok YeJin Woo ChangBMCarticleAlzheimer diseaseFocused ultrasoundBlood–brain barrierAmyloid beta-peptidesNeurology. Diseases of the nervous systemRC346-429ENTranslational Neurodegeneration, Vol 10, Iss 1, Pp 1-11 (2021)
institution DOAJ
collection DOAJ
language EN
topic Alzheimer disease
Focused ultrasound
Blood–brain barrier
Amyloid beta-peptides
Neurology. Diseases of the nervous system
RC346-429
spellingShingle Alzheimer disease
Focused ultrasound
Blood–brain barrier
Amyloid beta-peptides
Neurology. Diseases of the nervous system
RC346-429
So Hee Park
Kyoungwon Baik
Seun Jeon
Won Seok Chang
Byoung Seok Ye
Jin Woo Chang
Extensive frontal focused ultrasound mediated blood–brain barrier opening for the treatment of Alzheimer’s disease: a proof-of-concept study
description Abstract Background Focused ultrasound (FUS)-mediated blood–brain barrier (BBB) opening has shown efficacy in removal of amyloid plaque and improvement of cognitive functions in preclinical studies, but this is rarely reported in clinical studies. This study was conducted to evaluate the safety, feasibility and potential benefits of repeated extensive BBB opening. Methods In this open-label, prospective study, six patients with Alzheimer’s disease (AD) were enrolled at Severance Hospital in Korea between August 2020 and September 2020. Five of them completed the study. FUS-mediated BBB opening, targeting the bilateral frontal lobe regions over 20 cm3, was performed twice at three-month intervals. Magnetic resonance imaging, 18F-Florbetaben (FBB) positron emission tomography, Caregiver-Administered Neuropsychiatric Inventory (CGA-NPI) and comprehensive neuropsychological tests were performed before and after the procedures. Results FUS targeted a mean volume of 21.1 ± 2.7 cm3 and BBB opening was confirmed at 95.7% ± 9.4% of the targeted volume. The frontal-to-other cortical region FBB standardized uptake value ratio at 3 months after the procedure showed a slight decrease, which was statistically significant, compared to the pre-procedure value (− 1.6%, 0.986 vs1.002, P = 0.043). The CGA-NPI score at 2 weeks after the second procedure significantly decreased compared to baseline (2.2 ± 3.0 vs 8.6 ± 6.0, P = 0.042), but recovered after 3 months (5.2 ± 5.8 vs 8.6 ± 6.0, P = 0.89). No adverse effects were observed. Conclusions The repeated and extensive BBB opening in the frontal lobe is safe and feasible for patients with AD. In addition, the BBB opening is potentially beneficial for amyloid removal in AD patients.
format article
author So Hee Park
Kyoungwon Baik
Seun Jeon
Won Seok Chang
Byoung Seok Ye
Jin Woo Chang
author_facet So Hee Park
Kyoungwon Baik
Seun Jeon
Won Seok Chang
Byoung Seok Ye
Jin Woo Chang
author_sort So Hee Park
title Extensive frontal focused ultrasound mediated blood–brain barrier opening for the treatment of Alzheimer’s disease: a proof-of-concept study
title_short Extensive frontal focused ultrasound mediated blood–brain barrier opening for the treatment of Alzheimer’s disease: a proof-of-concept study
title_full Extensive frontal focused ultrasound mediated blood–brain barrier opening for the treatment of Alzheimer’s disease: a proof-of-concept study
title_fullStr Extensive frontal focused ultrasound mediated blood–brain barrier opening for the treatment of Alzheimer’s disease: a proof-of-concept study
title_full_unstemmed Extensive frontal focused ultrasound mediated blood–brain barrier opening for the treatment of Alzheimer’s disease: a proof-of-concept study
title_sort extensive frontal focused ultrasound mediated blood–brain barrier opening for the treatment of alzheimer’s disease: a proof-of-concept study
publisher BMC
publishDate 2021
url https://doaj.org/article/f18ef97d94344d85a042423ae5670bea
work_keys_str_mv AT soheepark extensivefrontalfocusedultrasoundmediatedbloodbrainbarrieropeningforthetreatmentofalzheimersdiseaseaproofofconceptstudy
AT kyoungwonbaik extensivefrontalfocusedultrasoundmediatedbloodbrainbarrieropeningforthetreatmentofalzheimersdiseaseaproofofconceptstudy
AT seunjeon extensivefrontalfocusedultrasoundmediatedbloodbrainbarrieropeningforthetreatmentofalzheimersdiseaseaproofofconceptstudy
AT wonseokchang extensivefrontalfocusedultrasoundmediatedbloodbrainbarrieropeningforthetreatmentofalzheimersdiseaseaproofofconceptstudy
AT byoungseokye extensivefrontalfocusedultrasoundmediatedbloodbrainbarrieropeningforthetreatmentofalzheimersdiseaseaproofofconceptstudy
AT jinwoochang extensivefrontalfocusedultrasoundmediatedbloodbrainbarrieropeningforthetreatmentofalzheimersdiseaseaproofofconceptstudy
_version_ 1718442483483934720