Cascaded gain-switching in the mid-infrared region
Abstract In this report, we demonstrate mid-infrared dual-waveband (i.e., ~3 μm and ~2 μm) pulses from a cascaded gain-switched Ho3+-doped ZBLAN fiber laser by the use of hybrid pumping of 1150 nm CW and pulse LDs for the first time. Stable ~3 μm gain-switched pulses with the maximum output power 26...
Guardado en:
Autores principales: | , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Nature Portfolio
2017
|
Materias: | |
Acceso en línea: | https://doaj.org/article/f1e548d2b8574992a0242bae26d1a9ae |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:f1e548d2b8574992a0242bae26d1a9ae |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:f1e548d2b8574992a0242bae26d1a9ae2021-12-02T15:05:43ZCascaded gain-switching in the mid-infrared region10.1038/s41598-017-17305-12045-2322https://doaj.org/article/f1e548d2b8574992a0242bae26d1a9ae2017-12-01T00:00:00Zhttps://doi.org/10.1038/s41598-017-17305-1https://doaj.org/toc/2045-2322Abstract In this report, we demonstrate mid-infrared dual-waveband (i.e., ~3 μm and ~2 μm) pulses from a cascaded gain-switched Ho3+-doped ZBLAN fiber laser by the use of hybrid pumping of 1150 nm CW and pulse LDs for the first time. Stable ~3 μm gain-switched pulses with the maximum output power 262.14 mW and shortest pulse duration of 0.824 μs were first gained at the repetition rate of 80 kHz and wavelength of 2928.5 nm. Then stable ~2 μm gain-switched pulses at 2068 nm were achieved at a switchable repetition rate between 40 kHz and 80 kHz. The maximum output power and shortest pulse duration were 75.23 mW and 0.787 μs, respectively (not simultaneously). Between them, there is a power-dependent μs-order time delay. This dual-waveband laser source has great potential in laser surgery, material processing.Hongyu LuoJianfeng LiChen ZhuXue LaiYongchen HaiYong LiuNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 7, Iss 1, Pp 1-7 (2017) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine R Science Q |
spellingShingle |
Medicine R Science Q Hongyu Luo Jianfeng Li Chen Zhu Xue Lai Yongchen Hai Yong Liu Cascaded gain-switching in the mid-infrared region |
description |
Abstract In this report, we demonstrate mid-infrared dual-waveband (i.e., ~3 μm and ~2 μm) pulses from a cascaded gain-switched Ho3+-doped ZBLAN fiber laser by the use of hybrid pumping of 1150 nm CW and pulse LDs for the first time. Stable ~3 μm gain-switched pulses with the maximum output power 262.14 mW and shortest pulse duration of 0.824 μs were first gained at the repetition rate of 80 kHz and wavelength of 2928.5 nm. Then stable ~2 μm gain-switched pulses at 2068 nm were achieved at a switchable repetition rate between 40 kHz and 80 kHz. The maximum output power and shortest pulse duration were 75.23 mW and 0.787 μs, respectively (not simultaneously). Between them, there is a power-dependent μs-order time delay. This dual-waveband laser source has great potential in laser surgery, material processing. |
format |
article |
author |
Hongyu Luo Jianfeng Li Chen Zhu Xue Lai Yongchen Hai Yong Liu |
author_facet |
Hongyu Luo Jianfeng Li Chen Zhu Xue Lai Yongchen Hai Yong Liu |
author_sort |
Hongyu Luo |
title |
Cascaded gain-switching in the mid-infrared region |
title_short |
Cascaded gain-switching in the mid-infrared region |
title_full |
Cascaded gain-switching in the mid-infrared region |
title_fullStr |
Cascaded gain-switching in the mid-infrared region |
title_full_unstemmed |
Cascaded gain-switching in the mid-infrared region |
title_sort |
cascaded gain-switching in the mid-infrared region |
publisher |
Nature Portfolio |
publishDate |
2017 |
url |
https://doaj.org/article/f1e548d2b8574992a0242bae26d1a9ae |
work_keys_str_mv |
AT hongyuluo cascadedgainswitchinginthemidinfraredregion AT jianfengli cascadedgainswitchinginthemidinfraredregion AT chenzhu cascadedgainswitchinginthemidinfraredregion AT xuelai cascadedgainswitchinginthemidinfraredregion AT yongchenhai cascadedgainswitchinginthemidinfraredregion AT yongliu cascadedgainswitchinginthemidinfraredregion |
_version_ |
1718388743378829312 |