Determination of split renal function using dynamic CT-angiography: preliminary results.

<h4>Objectives</h4>To determine the feasibility of a dynamic CT angiography-protocol with regard to simultaneous assessment of renal anatomy and function.<h4>Methods</h4>7 healthy potential kidney donors (58 ± 7 years) underwent a dynamic computed tomography angiography (CTA)...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Andreas Helck, Ulf Schönermarck, Antje Habicht, Mike Notohamiprodjo, Manfred Stangl, Ernst Klotz, Konstantin Nikolaou, Christian la Fougère, Dirk Andrè Clevert, Maximilian Reiser, Christoph Becker
Formato: article
Lenguaje:EN
Publicado: Public Library of Science (PLoS) 2014
Materias:
R
Q
Acceso en línea:https://doaj.org/article/f2379791a1e644caaaa33921a6bdc2d4
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:<h4>Objectives</h4>To determine the feasibility of a dynamic CT angiography-protocol with regard to simultaneous assessment of renal anatomy and function.<h4>Methods</h4>7 healthy potential kidney donors (58 ± 7 years) underwent a dynamic computed tomography angiography (CTA) using a 128-slice CT-scanner with continuous bi-directional table movement, allowing the coverage of a scan range of 18 cm within 1.75 sec. Twelve scans of the kidneys (n = 14) were acquired every 3.5 seconds with the aim to simultaneously obtain CTA and renal function data. Image quality was assessed quantitatively (HU-measurements) and qualitatively (grade 1-4, 1 = best). The glomerular filtration rate (GFR) was calculated by a modified Patlak method and compared with the split renal function obtained with renal scintigraphy.<h4>Results</h4>Mean maximum attenuation was 464 ± 58 HU, 435 ± 48 HU and 277 ± 29 HU in the aorta, renal arteries, and renal veins, respectively. The abdominal aorta and all renal vessels were depicted excellently (grade 1.0). The image quality score for cortex differentiation was 1.6 ± 0.49, for the renal parenchyma 2.4 ± 0.49. GFR obtained from dynamic CTA correlated well with renal scintigraphy with a correlation coefficient of r = 0.84; P = 0.0002 (n = 14). The average absolute deviation was 1.6 mL/min. The average effective dose was 8.96 mSv.<h4>Conclusion</h4>Comprehensive assessment of renal anatomy and function is feasible using a single dynamic CT angiography examination. The proposed protocol may help to improve management in case of asymmetric kidney function as well as to simplify evaluation of potential living kidney donors.