Disproportionate contribution of right middle lobe to emphysema and gas trapping on computed tomography.

<h4>Rationale</h4>Given that the diagnosis of chronic obstructive pulmonary disease (COPD) relies on demonstrating airflow limitation by spirometry, which is known to be poorly sensitive to early disease, and to regional differences in emphysema, we sought to evaluate individual lobar co...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Surya P Bhatt, Jessica C Sieren, John D Newell, Alejandro P Comellas, Eric A Hoffman
Formato: article
Lenguaje:EN
Publicado: Public Library of Science (PLoS) 2014
Materias:
R
Q
Acceso en línea:https://doaj.org/article/f3173b0dbe1c49f1bcbe0fa778941b0d
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:<h4>Rationale</h4>Given that the diagnosis of chronic obstructive pulmonary disease (COPD) relies on demonstrating airflow limitation by spirometry, which is known to be poorly sensitive to early disease, and to regional differences in emphysema, we sought to evaluate individual lobar contributions to global spirometric measures.<h4>Methods</h4>Subjects with COPD were compared with smokers without airflow obstruction, and non-smokers. Emphysema (% low attenuation area, LAAinsp<-950 HU, at end-inspiration) and gas trapping (%LAAexp<-856 HU at end-expiration) on CT were quantified using density mask analyses for the whole lung and for individual lobes, and distribution across lobes and strength of correlation with spirometry were compared.<h4>Results</h4>The right middle lobe had the highest %LAAinsp<-950 HU in smokers and controls, and the highest %LAAexp<-856 HU in all three groups. While RML contributed to emphysema and gas trapping disproportionately to its relatively small size, it also showed the least correlation with spirometry. There was no change in correlation of whole lung CT metrics with spirometry when the middle lobe was excluded from analyses. Similarly, RML had the highest %LAAexp<-856 HU while having the least correlation with spirometry.<h4>Conclusions</h4>Because of the right middle lobe's disproportionate contribution to CT-based emphysema measurements, and low contribution to spirometry, longitudinal studies of emphysema progression may benefit from independent analysis of the middle lobe in whole lung quantitative CT assessments. Our findings may also have implications for heterogeneity assessments and target lobe selection for lung volume reduction.<h4>Clinical trial registration</h4>ClinicalTrials.gov NCT00608764.