Laterally applied single bone plate option for fixation of complete diaphyseal fracture of a third metatarsal bone in a circus work pony

Background: Complete fractures of the third metacarpal / metatarsal bones (Mc/t3) are not common, but can occur in various situations and all types of horses, contributing for approximately one third of all long bone fractures in the horse, mostly related to external trauma or to high energy injurie...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Isabel R. Dias, Luís M. Maia, Miguel Quaresma, Mário Cotovio, Filipe C. Silva
Formato: article
Lenguaje:EN
Publicado: Tripoli University 2021
Materias:
Acceso en línea:https://doaj.org/article/f430d8a6dd664518bf6cd22c2628fa60
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:f430d8a6dd664518bf6cd22c2628fa60
record_format dspace
spelling oai:doaj.org-article:f430d8a6dd664518bf6cd22c2628fa602021-11-21T05:54:31ZLaterally applied single bone plate option for fixation of complete diaphyseal fracture of a third metatarsal bone in a circus work pony10.5455/OVJ.2021.v11.i4.142226-44852218-6050https://doaj.org/article/f430d8a6dd664518bf6cd22c2628fa602021-11-01T00:00:00Zhttps://www.openveterinaryjournal.com/OVJ-2021-08-163%20I.R.%20Dias%20et%20al.pdfhttps://doaj.org/toc/2226-4485https://doaj.org/toc/2218-6050Background: Complete fractures of the third metacarpal / metatarsal bones (Mc/t3) are not common, but can occur in various situations and all types of horses, contributing for approximately one third of all long bone fractures in the horse, mostly related to external trauma or to high energy injuries. To stabilize Mc/t3 fractures in the horse, conservative management with walking casts and/or open reduction and internal fixation techniques are referred in the scientific literature, these last one generally by double platting application to bone surface in 90º. In the present case will be described a Mt3 complete diaphyseal fracture stabilization on an adult pony from a circus by applying only one bone plate. This work pony could return to its previous activity fully recovered 3 months after fracture stabilization. Case Description: A 7-year-old, male, Shetland pony (103 kg), used for performance work at a circus was admitted to the Veterinary Teaching Hospital of UTAD, presenting on lateral recumbency after being struck by a truck. On physical examination a penetrating wound of small dimension was detected at the medial aspect of the right hindlimb. After radiographic examination, a complete diaphyseal fracture with slight obliquity of the right Mt3 was confirmed. The owner opted for surgical repair thus fracture stabilization was achieved by the placement of just a single 8-hole 4.5 mm broad dynamic compression plate applied to the lateral face of Mt3 in compression function with 7 cortical screws (4.5 mm). Post-operatively a full limb cast was performed and maintained for 4 weeks while the animal was kept under movement limitation at the hospital facilities for this period of time although the animal stayed until his full recovery 3 months’ post-surgery. Conclusion: A complete recovery was achieved and the animal returned to the previous level of exercise without any significant postoperative complications or degree of lameness. In the authors knowledge, this is the first case report where stabilization of a complete Mt3 diaphyseal fracture was attain using a single compression plate contoured to the lateral face of the bone, instead of double plating, on an adult work pony from a circus subjected to a very demanding and intense physical activity.Isabel R. DiasLuís M. MaiaMiguel QuaresmaMário CotovioFilipe C. SilvaTripoli Universityarticledynamic compression plateinternal fixationcomplete diaphyseal third metatarsal fractureponyZoologyQL1-991ENOpen Veterinary Journal, Vol 11, Iss 4, Pp 645-650 (2021)
institution DOAJ
collection DOAJ
language EN
topic dynamic compression plate
internal fixation
complete diaphyseal third metatarsal fracture
pony
Zoology
QL1-991
spellingShingle dynamic compression plate
internal fixation
complete diaphyseal third metatarsal fracture
pony
Zoology
QL1-991
Isabel R. Dias
Luís M. Maia
Miguel Quaresma
Mário Cotovio
Filipe C. Silva
Laterally applied single bone plate option for fixation of complete diaphyseal fracture of a third metatarsal bone in a circus work pony
description Background: Complete fractures of the third metacarpal / metatarsal bones (Mc/t3) are not common, but can occur in various situations and all types of horses, contributing for approximately one third of all long bone fractures in the horse, mostly related to external trauma or to high energy injuries. To stabilize Mc/t3 fractures in the horse, conservative management with walking casts and/or open reduction and internal fixation techniques are referred in the scientific literature, these last one generally by double platting application to bone surface in 90º. In the present case will be described a Mt3 complete diaphyseal fracture stabilization on an adult pony from a circus by applying only one bone plate. This work pony could return to its previous activity fully recovered 3 months after fracture stabilization. Case Description: A 7-year-old, male, Shetland pony (103 kg), used for performance work at a circus was admitted to the Veterinary Teaching Hospital of UTAD, presenting on lateral recumbency after being struck by a truck. On physical examination a penetrating wound of small dimension was detected at the medial aspect of the right hindlimb. After radiographic examination, a complete diaphyseal fracture with slight obliquity of the right Mt3 was confirmed. The owner opted for surgical repair thus fracture stabilization was achieved by the placement of just a single 8-hole 4.5 mm broad dynamic compression plate applied to the lateral face of Mt3 in compression function with 7 cortical screws (4.5 mm). Post-operatively a full limb cast was performed and maintained for 4 weeks while the animal was kept under movement limitation at the hospital facilities for this period of time although the animal stayed until his full recovery 3 months’ post-surgery. Conclusion: A complete recovery was achieved and the animal returned to the previous level of exercise without any significant postoperative complications or degree of lameness. In the authors knowledge, this is the first case report where stabilization of a complete Mt3 diaphyseal fracture was attain using a single compression plate contoured to the lateral face of the bone, instead of double plating, on an adult work pony from a circus subjected to a very demanding and intense physical activity.
format article
author Isabel R. Dias
Luís M. Maia
Miguel Quaresma
Mário Cotovio
Filipe C. Silva
author_facet Isabel R. Dias
Luís M. Maia
Miguel Quaresma
Mário Cotovio
Filipe C. Silva
author_sort Isabel R. Dias
title Laterally applied single bone plate option for fixation of complete diaphyseal fracture of a third metatarsal bone in a circus work pony
title_short Laterally applied single bone plate option for fixation of complete diaphyseal fracture of a third metatarsal bone in a circus work pony
title_full Laterally applied single bone plate option for fixation of complete diaphyseal fracture of a third metatarsal bone in a circus work pony
title_fullStr Laterally applied single bone plate option for fixation of complete diaphyseal fracture of a third metatarsal bone in a circus work pony
title_full_unstemmed Laterally applied single bone plate option for fixation of complete diaphyseal fracture of a third metatarsal bone in a circus work pony
title_sort laterally applied single bone plate option for fixation of complete diaphyseal fracture of a third metatarsal bone in a circus work pony
publisher Tripoli University
publishDate 2021
url https://doaj.org/article/f430d8a6dd664518bf6cd22c2628fa60
work_keys_str_mv AT isabelrdias laterallyappliedsingleboneplateoptionforfixationofcompletediaphysealfractureofathirdmetatarsalboneinacircusworkpony
AT luismmaia laterallyappliedsingleboneplateoptionforfixationofcompletediaphysealfractureofathirdmetatarsalboneinacircusworkpony
AT miguelquaresma laterallyappliedsingleboneplateoptionforfixationofcompletediaphysealfractureofathirdmetatarsalboneinacircusworkpony
AT mariocotovio laterallyappliedsingleboneplateoptionforfixationofcompletediaphysealfractureofathirdmetatarsalboneinacircusworkpony
AT filipecsilva laterallyappliedsingleboneplateoptionforfixationofcompletediaphysealfractureofathirdmetatarsalboneinacircusworkpony
_version_ 1718419399018283008