Challenge of Liquid Stressed Protective Materials and Environmental Persistence of Ebola Virus

Abstract After the largest Ebola virus outbreak in history, experts have attempted to answer how the Zaire ebolavirus species emerged in West Africa and caused chains of human-to-human transmission. The widespread and untimely infection of Health Care Workers (HCW) in the affected countries accelera...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Aidan M. Nikiforuk, Todd A. Cutts, Steven S. Theriault, Bradley W. M. Cook
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2017
Materias:
R
Q
Acceso en línea:https://doaj.org/article/f5239b90f5184d60859b6810802c96bf
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:f5239b90f5184d60859b6810802c96bf
record_format dspace
spelling oai:doaj.org-article:f5239b90f5184d60859b6810802c96bf2021-12-02T11:40:43ZChallenge of Liquid Stressed Protective Materials and Environmental Persistence of Ebola Virus10.1038/s41598-017-04137-22045-2322https://doaj.org/article/f5239b90f5184d60859b6810802c96bf2017-06-01T00:00:00Zhttps://doi.org/10.1038/s41598-017-04137-2https://doaj.org/toc/2045-2322Abstract After the largest Ebola virus outbreak in history, experts have attempted to answer how the Zaire ebolavirus species emerged in West Africa and caused chains of human-to-human transmission. The widespread and untimely infection of Health Care Workers (HCW) in the affected countries accelerated spread of the virus within the community. Among the reasons attributed to this trend, it must be considered that HCW were exposed to the virus in their occupational environment. The contribution of environmental conditions to the spread of Ebola in West Africa was examined by investigating the effect of temperature/humidity on the virus’s environmental persistence and by modeling if saturation (liquid stress) allows for penetration of Ebola virus through personal protective equipment (PPE). Ebola-Makona virus persisted on PPE and materials found in outbreak settings for less than 72 hours at 27 °C and 80% relative humidity (RH). A difference in virus penetration was observed between dry (5%, 1/21 tests) and saturated (33%, 7/21 tests) samples of PPE. Infectious virus particles penetrated through saturated coupons of Tyvek Micro Clean, Tychem QC, whole surgical masks and N95 respirators. These findings suggest inclusion of saturation or similar liquid stress simulation in protective equipment testing standards.Aidan M. NikiforukTodd A. CuttsSteven S. TheriaultBradley W. M. CookNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 7, Iss 1, Pp 1-9 (2017)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Aidan M. Nikiforuk
Todd A. Cutts
Steven S. Theriault
Bradley W. M. Cook
Challenge of Liquid Stressed Protective Materials and Environmental Persistence of Ebola Virus
description Abstract After the largest Ebola virus outbreak in history, experts have attempted to answer how the Zaire ebolavirus species emerged in West Africa and caused chains of human-to-human transmission. The widespread and untimely infection of Health Care Workers (HCW) in the affected countries accelerated spread of the virus within the community. Among the reasons attributed to this trend, it must be considered that HCW were exposed to the virus in their occupational environment. The contribution of environmental conditions to the spread of Ebola in West Africa was examined by investigating the effect of temperature/humidity on the virus’s environmental persistence and by modeling if saturation (liquid stress) allows for penetration of Ebola virus through personal protective equipment (PPE). Ebola-Makona virus persisted on PPE and materials found in outbreak settings for less than 72 hours at 27 °C and 80% relative humidity (RH). A difference in virus penetration was observed between dry (5%, 1/21 tests) and saturated (33%, 7/21 tests) samples of PPE. Infectious virus particles penetrated through saturated coupons of Tyvek Micro Clean, Tychem QC, whole surgical masks and N95 respirators. These findings suggest inclusion of saturation or similar liquid stress simulation in protective equipment testing standards.
format article
author Aidan M. Nikiforuk
Todd A. Cutts
Steven S. Theriault
Bradley W. M. Cook
author_facet Aidan M. Nikiforuk
Todd A. Cutts
Steven S. Theriault
Bradley W. M. Cook
author_sort Aidan M. Nikiforuk
title Challenge of Liquid Stressed Protective Materials and Environmental Persistence of Ebola Virus
title_short Challenge of Liquid Stressed Protective Materials and Environmental Persistence of Ebola Virus
title_full Challenge of Liquid Stressed Protective Materials and Environmental Persistence of Ebola Virus
title_fullStr Challenge of Liquid Stressed Protective Materials and Environmental Persistence of Ebola Virus
title_full_unstemmed Challenge of Liquid Stressed Protective Materials and Environmental Persistence of Ebola Virus
title_sort challenge of liquid stressed protective materials and environmental persistence of ebola virus
publisher Nature Portfolio
publishDate 2017
url https://doaj.org/article/f5239b90f5184d60859b6810802c96bf
work_keys_str_mv AT aidanmnikiforuk challengeofliquidstressedprotectivematerialsandenvironmentalpersistenceofebolavirus
AT toddacutts challengeofliquidstressedprotectivematerialsandenvironmentalpersistenceofebolavirus
AT stevenstheriault challengeofliquidstressedprotectivematerialsandenvironmentalpersistenceofebolavirus
AT bradleywmcook challengeofliquidstressedprotectivematerialsandenvironmentalpersistenceofebolavirus
_version_ 1718395618635808768