Poly (Orange CD) sensor for paracetamol in presence of folic acid and dopamine
Abstract In the present work, Orange CD was chosen as an intriguing modifier for the electropolymerization on the surface of CPE by the CV technique. A novel, sensitive, and cost-effective poly (Orange CD) MCPE (PoOCD/MCPE) sensor was utilized for the selective detection of paracetamol (PA) in 0.2 M...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Nature Portfolio
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/f525a067d15743269efca80c49950ffb |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:f525a067d15743269efca80c49950ffb |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:f525a067d15743269efca80c49950ffb2021-11-21T12:24:06ZPoly (Orange CD) sensor for paracetamol in presence of folic acid and dopamine10.1038/s41598-021-01311-52045-2322https://doaj.org/article/f525a067d15743269efca80c49950ffb2021-11-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-01311-5https://doaj.org/toc/2045-2322Abstract In the present work, Orange CD was chosen as an intriguing modifier for the electropolymerization on the surface of CPE by the CV technique. A novel, sensitive, and cost-effective poly (Orange CD) MCPE (PoOCD/MCPE) sensor was utilized for the selective detection of paracetamol (PA) in 0.2 M phosphate buffer solution (PBS) of pH 7.4. The oxidation peak current of PA was vastly enhanced at the sensor. The scan rate study is suggested that electro-oxidation of PA was adsorption-controlled. The pH study testifies the redox pathways transport with the same quantity of electrons and protons. The detection limit of PA is found to be 2.64 µM. DPV results show that substantial peak separation between PA, folic acid (FA), and dopamine (DA) could be facilitating their individual and simultaneous determination on the sensor. The decorated sensor demonstrates high sensitivity, stability, reproducibility, repeatability and has been successfully exploited for the detection of PA in a tablet with promising results.S. D. SukanyaB. E. Kumara SwamyJ. K. ShashikumaraS. C. SharmaS. A. HariprasadNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-12 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine R Science Q |
spellingShingle |
Medicine R Science Q S. D. Sukanya B. E. Kumara Swamy J. K. Shashikumara S. C. Sharma S. A. Hariprasad Poly (Orange CD) sensor for paracetamol in presence of folic acid and dopamine |
description |
Abstract In the present work, Orange CD was chosen as an intriguing modifier for the electropolymerization on the surface of CPE by the CV technique. A novel, sensitive, and cost-effective poly (Orange CD) MCPE (PoOCD/MCPE) sensor was utilized for the selective detection of paracetamol (PA) in 0.2 M phosphate buffer solution (PBS) of pH 7.4. The oxidation peak current of PA was vastly enhanced at the sensor. The scan rate study is suggested that electro-oxidation of PA was adsorption-controlled. The pH study testifies the redox pathways transport with the same quantity of electrons and protons. The detection limit of PA is found to be 2.64 µM. DPV results show that substantial peak separation between PA, folic acid (FA), and dopamine (DA) could be facilitating their individual and simultaneous determination on the sensor. The decorated sensor demonstrates high sensitivity, stability, reproducibility, repeatability and has been successfully exploited for the detection of PA in a tablet with promising results. |
format |
article |
author |
S. D. Sukanya B. E. Kumara Swamy J. K. Shashikumara S. C. Sharma S. A. Hariprasad |
author_facet |
S. D. Sukanya B. E. Kumara Swamy J. K. Shashikumara S. C. Sharma S. A. Hariprasad |
author_sort |
S. D. Sukanya |
title |
Poly (Orange CD) sensor for paracetamol in presence of folic acid and dopamine |
title_short |
Poly (Orange CD) sensor for paracetamol in presence of folic acid and dopamine |
title_full |
Poly (Orange CD) sensor for paracetamol in presence of folic acid and dopamine |
title_fullStr |
Poly (Orange CD) sensor for paracetamol in presence of folic acid and dopamine |
title_full_unstemmed |
Poly (Orange CD) sensor for paracetamol in presence of folic acid and dopamine |
title_sort |
poly (orange cd) sensor for paracetamol in presence of folic acid and dopamine |
publisher |
Nature Portfolio |
publishDate |
2021 |
url |
https://doaj.org/article/f525a067d15743269efca80c49950ffb |
work_keys_str_mv |
AT sdsukanya polyorangecdsensorforparacetamolinpresenceoffolicacidanddopamine AT bekumaraswamy polyorangecdsensorforparacetamolinpresenceoffolicacidanddopamine AT jkshashikumara polyorangecdsensorforparacetamolinpresenceoffolicacidanddopamine AT scsharma polyorangecdsensorforparacetamolinpresenceoffolicacidanddopamine AT sahariprasad polyorangecdsensorforparacetamolinpresenceoffolicacidanddopamine |
_version_ |
1718419040555237376 |