Poly (Orange CD) sensor for paracetamol in presence of folic acid and dopamine

Abstract In the present work, Orange CD was chosen as an intriguing modifier for the electropolymerization on the surface of CPE by the CV technique. A novel, sensitive, and cost-effective poly (Orange CD) MCPE (PoOCD/MCPE) sensor was utilized for the selective detection of paracetamol (PA) in 0.2 M...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: S. D. Sukanya, B. E. Kumara Swamy, J. K. Shashikumara, S. C. Sharma, S. A. Hariprasad
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/f525a067d15743269efca80c49950ffb
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:f525a067d15743269efca80c49950ffb
record_format dspace
spelling oai:doaj.org-article:f525a067d15743269efca80c49950ffb2021-11-21T12:24:06ZPoly (Orange CD) sensor for paracetamol in presence of folic acid and dopamine10.1038/s41598-021-01311-52045-2322https://doaj.org/article/f525a067d15743269efca80c49950ffb2021-11-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-01311-5https://doaj.org/toc/2045-2322Abstract In the present work, Orange CD was chosen as an intriguing modifier for the electropolymerization on the surface of CPE by the CV technique. A novel, sensitive, and cost-effective poly (Orange CD) MCPE (PoOCD/MCPE) sensor was utilized for the selective detection of paracetamol (PA) in 0.2 M phosphate buffer solution (PBS) of pH 7.4. The oxidation peak current of PA was vastly enhanced at the sensor. The scan rate study is suggested that electro-oxidation of PA was adsorption-controlled. The pH study testifies the redox pathways transport with the same quantity of electrons and protons. The detection limit of PA is found to be 2.64 µM. DPV results show that substantial peak separation between PA, folic acid (FA), and dopamine (DA) could be facilitating their individual and simultaneous determination on the sensor. The decorated sensor demonstrates high sensitivity, stability, reproducibility, repeatability and has been successfully exploited for the detection of PA in a tablet with promising results.S. D. SukanyaB. E. Kumara SwamyJ. K. ShashikumaraS. C. SharmaS. A. HariprasadNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-12 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
S. D. Sukanya
B. E. Kumara Swamy
J. K. Shashikumara
S. C. Sharma
S. A. Hariprasad
Poly (Orange CD) sensor for paracetamol in presence of folic acid and dopamine
description Abstract In the present work, Orange CD was chosen as an intriguing modifier for the electropolymerization on the surface of CPE by the CV technique. A novel, sensitive, and cost-effective poly (Orange CD) MCPE (PoOCD/MCPE) sensor was utilized for the selective detection of paracetamol (PA) in 0.2 M phosphate buffer solution (PBS) of pH 7.4. The oxidation peak current of PA was vastly enhanced at the sensor. The scan rate study is suggested that electro-oxidation of PA was adsorption-controlled. The pH study testifies the redox pathways transport with the same quantity of electrons and protons. The detection limit of PA is found to be 2.64 µM. DPV results show that substantial peak separation between PA, folic acid (FA), and dopamine (DA) could be facilitating their individual and simultaneous determination on the sensor. The decorated sensor demonstrates high sensitivity, stability, reproducibility, repeatability and has been successfully exploited for the detection of PA in a tablet with promising results.
format article
author S. D. Sukanya
B. E. Kumara Swamy
J. K. Shashikumara
S. C. Sharma
S. A. Hariprasad
author_facet S. D. Sukanya
B. E. Kumara Swamy
J. K. Shashikumara
S. C. Sharma
S. A. Hariprasad
author_sort S. D. Sukanya
title Poly (Orange CD) sensor for paracetamol in presence of folic acid and dopamine
title_short Poly (Orange CD) sensor for paracetamol in presence of folic acid and dopamine
title_full Poly (Orange CD) sensor for paracetamol in presence of folic acid and dopamine
title_fullStr Poly (Orange CD) sensor for paracetamol in presence of folic acid and dopamine
title_full_unstemmed Poly (Orange CD) sensor for paracetamol in presence of folic acid and dopamine
title_sort poly (orange cd) sensor for paracetamol in presence of folic acid and dopamine
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/f525a067d15743269efca80c49950ffb
work_keys_str_mv AT sdsukanya polyorangecdsensorforparacetamolinpresenceoffolicacidanddopamine
AT bekumaraswamy polyorangecdsensorforparacetamolinpresenceoffolicacidanddopamine
AT jkshashikumara polyorangecdsensorforparacetamolinpresenceoffolicacidanddopamine
AT scsharma polyorangecdsensorforparacetamolinpresenceoffolicacidanddopamine
AT sahariprasad polyorangecdsensorforparacetamolinpresenceoffolicacidanddopamine
_version_ 1718419040555237376